Installation and Configuration Part Number: EK-DLMT1-IN. C01 March 1998 This manual describes how to install, cable, and configure the DIGITAL MultiSwitch Hub 612TX when residing in a DIGITAL MultiSwitch 600 System (Stack Director or Stack Station) or a DIGITAL MultiSwitch 900 (formely DEChub 900 MultiSwitch). Revision/Update Information: This is a revised document. Digital Equipment Corporation makes no representations that the use of its products in the manner described in this publication will not infringe on existing or future patent rights, nor do the descriptions contained in this publication imply the granting of licenses to make, use, or sell equipment or software in accordance with the description. Possession, use, or copying of the software described in this publication is authorized only pursuant to a valid written license from Digital or an authorized sublicensor. Digital Equipment Corporation 1998. All rights reserved. Printed in U.S.A. The following are trademarks of Digital Equipment Corporation: clearVISN, DEC, DEChub, DIGITAL, the DIGITAL logo, and ThinWire. All other trademarks and registered trademarks are the property of their respective holders. FCC Notice -- Class A Computing Device: This equipment generates, uses, and may emit radio frequency energy. The equipment has been type tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of FCC rules, which are designed to provide reasonable protection against such radio frequency interference. Operation of this equipment in a residential area may cause interference in which case the user at his own expense will be required to take whatever measures may be required to correct the interference. Any modifications to this device - unless expressly approved by the manufacturer - can void the user's authority to operate this equipment under part 15 of the FCC rules. VCCI Notice -- Class A Computing Device: This equipment is in the Class A category (information equipment to be used in commercial and/or industrial areas) and conforms to the standards set by the Voluntary Control Council for Interference by Data Processing Equipment and Electronic Office Machines aimed at preventing radio interference in commercial and/or industrial areas. Consequently, when used in a residential area or in an adjacent area thereto, radio interference may be caused to radios and TV receivers. Read the instructions for correct handling. CE Notice -- Class A Computing Device: Warning! This is a Class A product. In a domestic environment, this product may cause radio interference, in which case the user may be required to take adequate measures. Achtung! Dieses ist ein Gert der Funkstrgrenzwertklasse A. In Wohnbereichen knnen bei Betrieb dieses Gertes Rundfunkstrungen auftreten, in welchen Fllen der Benutzer fr entsprechende Gegenmanahmen verantwortlich ist. Avertissement! Cet appareil est un appareil de Classe A. Dans un environnement rsidentiel cet appareil peut provoquer des brouillages radiolectriques. Dans ce cas, il peut tre demand l'utilisateur de prendre les mesures appropries. Contents Preface Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .xv About this Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .xv Intended Audience . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .xv Organization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xvi Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xviii Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xix Part I - DIGITAL MultiSwitch Hub 612TX 1 Product Description Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 In This Chapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 Network Topology for Class II Hubs to Switches with MMIs . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2 Auto-Negotiation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3 User Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4 Technology Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5 Ethernet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5 Fast Ethernet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5 Shared Hubs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5 What Is the DIGITAL MultiSwitch 600 System? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6 DIGITAL MultiSwitch 600 System Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-8 Using DIGITAL MultiSwitch 600 System Modules in a DIGITAL MultiSwitch 900 . . . . . . . . . 1-9 What Is the DIGITAL MultiSwitch Hub 612TX? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-10 DIGITAL MultiSwitch Hub 612TX Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-11 MIB Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-12 Remote Monitoring (RMON) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-12 DIGITAL MultiSwitch Hub 612TX Front Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-13 DIGITAL MultiSwitch Hub 612TX Back Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-14 iii 2 Installing A Modular Media Interface Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1 In This Chapter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1 Installing DIGITAL MultiSwitch Hub 612TX Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2 Required Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2 Removing the Dust Cover . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3 Installing the MM-100 (Hot-Swappable) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4 3 Module Installation and Cabling Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1 In This Chapter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1 Installing a Hub 612TX in a Stack Director or Stack Station . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2 Installing the DIGITAL MultiSwitch Hub 612TX in a DIGITAL MultiSwitch 900 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4 Task 1: Compare the Power Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-5 Task 2: Seat the Module into the DIGITAL MultiSwitch 900 . . . . . . . . . . . . . . . . . . . . . . . 3-6 Task 3: Verify Initial LED Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-7 Task 4: Connect the Setup Port Cables to the DIGITAL MultiSwitch 900. . . . . . . . . . . . . . 3-8 Connecting Cables to the 100BaseTX Ports on the DIGITAL MultiSwitch Hub 612TX . . . . . 3-10 4 Module Configuration Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1 In This Chapter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1 Configuring the Module in a Stack Director or DIGITAL MultiSwitch 900 . . . . . . . . . . . . . . . . 4-3 [9] Start Redirect Mode. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-4 Using the Module's Menus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-5 [1] Restart with Factory Defaults. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-6 [2] Restart with Current Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-7 [3] Show Current Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-8 [4] Dump Error Log . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-9 Configuring the Module in a Stack Station . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-10 [1] Restart with Factory Defaults. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-11 [2] Restart with Current Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-12 [3] Show Current Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-13 [4] Dump Error Log . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-14 iv 5 Module Management Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1 In This Chapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1 What Is clearVISN? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-2 MultiChassis Manager . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-2 Stack Manager . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-2 Requirements for Managing the Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-3 DIGITAL MultiSwitch 600 System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-3 DIGITAL MultiSwitch 900 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-3 Managed Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-4 Repeater Summary Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-5 Repeater Port Summary Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-7 Repeater Port Details Window. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-8 Repeater Security Summary Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-10 Repeater Security Intrusion Log Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-11 MIBs Supported by the DIGITAL MultiSwitch Hub 612TX . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-12 6 Removing a Module and Option Cards Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-1 In This Chapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-1 Removing Modules from the DIGITAL MultiSwitch 600 System (Hot-Swappable). . . . . . . . . . 6-2 Removing Modules from the DIGITAL MultiSwitch 900 (Hot-Swappable) . . . . . . . . . . . . . . . . 6-4 Removing Cables from the 100BaseTX Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-6 Removing the MM-100 (Hot-Swappable) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-7 Replacing the Dust Cover on the DIGITAL MultiSwitch Hub 612TX . . . . . . . . . . . . . . . . . . . . . 6-9 Part II - DIGITAL MultiSwitch 600 System 7 Stack Description Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-1 In This Chapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-1 What Is the DIGITAL MultiSwitch 600 System? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-2 MultiSwitch 600 Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-3 DIGITAL MultiSwitch 600 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-6 What Is a Stack Director? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-7 v Stack Director Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-7 Supported MIBs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-8 Stack Director Front Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-9 Stack Director Back Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-11 What Is a Stack Station?. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-12 Common Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-12 Specific Feature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-12 Stack Station Front Panel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-13 Stack Station Back Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-14 8 Assembling a Stack Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-1 In This Chapter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-1 Planning the Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-2 Planning Considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-2 Cable Restrictions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-3 Building a DIGITAL MultiSwitch 600 Stack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-4 Task 1: Securing a Stack Director or Stack Station to Mounting Tray . . . . . . . . . . . . . . . . . 8-4 Securing a Stack Director to Mounting Tray . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-5 Securing a Stack Station to Mounting Tray . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-6 Task 2: Securing the Mounting Tray to the Rack Mount . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-7 Task 3: Inserting the Stack Interconnect Card and Functional Module. . . . . . . . . . . . . . . . . 8-9 Task 4: Attaching the Next Level in the Stack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-10 Task 5: Cabling the Stack Director and Stack Station . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-12 Setup Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-14 Task 6: Connecting Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-15 Task 7: Adding a Stack Level after Initial Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-17 9 Managing a Stack Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-1 In This Chapter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-1 In-Band and Out-of-Band Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-2 Connecting to a Network Management Station . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-3 SNMP Management Applications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-4 Backplane Auto Healing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-5 Installation Menu Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-6 Using the Setup Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-6 Modes of Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-6 Connecting a Terminal to the Setup Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-6 vi Installation Menu Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-7 Menu Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-8 [1] Restart with Factory Defaults. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-9 [2] Restart with Current Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-10 [3] Show Current Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-11 [4] Configure IP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-12 IP Configure Selections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-12 [1] Set SNMP Read/Write Community . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-13 [2] Add SNMP Trap Addresses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-14 [3] Delete SNMP Trap Addresses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-15 [4] Set In-Band Interface IP Address . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-16 [5] Set Out-of-Band Interface IP Address . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-17 [6] Enable/Disable BootP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-18 [5] Dump Error Log . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-19 [6] Downline Upgrade (DLU) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-20 Approximate Downline Upgrade Completion Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-20 Initial Setup Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-21 Selecting the Level to be Upgraded . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-21 Entering the Load File Name . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-22 Load Host IP Address . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-22 Choosing a Network Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-22 TFTP Load Host and Image File Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-24 Download Processing Stages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-24 Download Processing for Network Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-25 Verifying the Upgrade . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-26 [7] Configure Out-of-Band Port. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-28 Out-of-Band Port Configuration Menu Selections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-28 Set Port Speed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-29 Enable/Disable RTS Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-30 [8] Start Event Display Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-31 [9] Start Redirect Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-32 10 Removing or Replacing a Level on the Stack Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-1 In This Chapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-1 Removing or Replacing Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-2 Task 1: Removing Power Cords and Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-2 Task 2: Removing or Replacing the Levels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-4 Task 3: Removing the Stack Director and Stack Station from the Tray. . . . . . . . . . . . . . . . 10-8 vii Part III - Reference Information A Problem Solving Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1 In This Appendix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1 DIGITAL MultiSwitch Hub 612TX LED States . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-2 Stack Director LED States . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-3 Stack Station LED States . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-5 DIGITAL MultiSwitch Hub 612TX Problem Solving Using the LEDs. . . . . . . . . . . . . . . . . . . . A-6 Stack Director Problem Solving Using the LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-8 Stack Station Problem Solving Using the LEDs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-10 B Connectors and Pin Assignments Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-1 In This Appendix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-1 DIGITAL MultiSwitch Hub 612TX Connectors and Pin Assignments . . . . . . . . . . . . . . . . . . . . B-2 100BaseTX (8-pin MJ) Port Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-2 Stack Director and Stack Station Connectors and Pin Assignments. . . . . . . . . . . . . . . . . . . . . . . B-3 Setup Port and Management Access Port Connector. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-3 OBM Port (9-Pin) Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-4 10Base2 Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-5 H8225 50-Ohm Terminator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-5 Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-6 H8571-J Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-6 C Product Specifications Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-1 In This Appendix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-1 Product Specifications for the DIGITAL MultiSwitch Hub 612TX. . . . . . . . . . . . . . . . . . . . . . . C-2 Product Specifications for the Stack Director . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-3 Product Specifications for the Stack Station . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-4 Acoustical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-5 Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-7 viii D Ordering Options Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .D-1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .D-1 In This Appendix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .D-1 Ordering Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .D-2 Ordering Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .D-4 Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .D-5 E Associated Documentation Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E-1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E-1 In This Appendix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E-1 Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E-2 How to Order Additional Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E-5 Correspondence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E-6 Documentation Comments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E-6 Online Services . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E-6 F Service Information and Support Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F-1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F-1 In This Appendix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F-1 Warranty Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F-2 G Accessing and Configuring RMON Groups Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .G-1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .G-1 In This Appendix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .G-1 What Is RMON? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .G-2 Groups Supported . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .G-3 How to Access RMON Groups . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .G-4 Accessing Statistics and History. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .G-4 Accessing Alarms and Events. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .G-4 Alarm and Event Table Entries. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .G-5 How Traps Work . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .G-7 ix Glossary Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Glossary-1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Gl ossary-1 In This Glossary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Glossary-1 Terms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Glossary-2 Index x Figures Fig ures 1-1 Single Class II Hub Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2 1-2 Two Class II Hub Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3 1-3 Various Class II Hub Configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4 1-4 DIGITAL MultiSwitch 600 System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-7 1-5 DIGITAL MultiSwitch Hub 612TX. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-10 1-6 DIGITAL MultiSwitch Hub 612TX Front Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-13 1-7 DIGITAL MultiSwitch Hub 612TX Back Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-14 2-1 Dust Cover Removal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3 2-2 Installing the MM-100 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4 3-1 Attaching the Module to the Stack Director or Stack Station . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3 3-2 Module Power Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-5 3-3 Seating the Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-6 3-4 Setup Port Cabling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-9 3-5 100BaseTX Cable Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-11 6-1 Removing the Module from a DIGITAL MultiSwitch 600 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-3 6-2 Removing the Module from a DIGITAL MultiSwitch 900 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-5 6-3 100BaseTX Cable Removal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-6 6-4 Removing the MM-100 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-7 6-5 Dust Cover Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-9 7-1 Typical DIGITAL MultiSwitch 600 Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-5 7-2 Stack Director Front Panel Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 -9 7-3 Stack Director Rear Panel Component Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-11 7-4 Stack Station Front Panel Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-13 7-5 Stack Station Back Panel Components. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-14 8-1 Stack Director Mounting Tray Attachment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-5 8-2 Stack Station Mounting Tray Attachment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-6 8-3 Standard 19" Rack Mount Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-7 xi 8-4 Relay Rack Mount Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-8 8-5 Stack Interconnect Card Attachment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-9 8-6 Mounting Plug Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-10 8-7 Next Stack Station Attachment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-11 8-8 Stack Director Port Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-12 8-9 Stack Station Port Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-13 8-10 IEC Power Connector Locations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-16 10-1 Connector Locations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-3 10-2 Removing a Stack Station . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-4 10-3 Stack Interconnect Card Removal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-7 10-4 Removing Stack Director and Stack Station from Mounting Tray . . . . . . . . . . . . . . . . . . . . . . 10-8 B-1 100BaseTX (8-pin MJ) Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-2 B-2 Stack Director and Stack Station Setup Port Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-3 B-3 OBM Port (9-Pin) Connector. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-4 B-4 10Base2 Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-5 B-5 50-Ohm Terminator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-5 B-6 H8571-J Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-6 xii Tables Tables 1-1 User Support for Various Class II Hub Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4 1-2 DIGITAL MultiSwitch Hub 612TX Front Panel Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-13 1-3 DIGITAL MultiSwitch Hub 612TX Back Panel Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-14 3-1 Cabling 100BaseTX Crossover Connector on Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-10 3-2 Cabling 100BaseTX Straight-Through Connector on MM-100. . . . . . . . . . . . . . . . . . . . . . . . 3-10 7-1 Stack Director Front Panel Component Descriptions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-9 7-2 Stack Director Back Panel Components. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-11 7-3 Stack Station Front Panel Component Descriptions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-13 7-4 Stack Station Back Panel Component Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-14 9-1 Terminal Setup Parameters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-6 9-2 Download Process Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-24 A-1 DIGITAL MultiSwitch Hub 612TX LED States . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-2 A-2 Stack Director LED States . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-3 A-3 Stack Station LED States . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-5 A-4 Problem Solving using LEDs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-6 A-5 Stack Director Error Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-8 A-6 Stack Station Error Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-10 B-1 100BaseTX (8-pin MJ) Connector Pin Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-2 B-2 Stack Director and Stack Station Setup Port Connector Pin Assignments. . . . . . . . . . . . . . . . . B-3 B-3 OBM Port (9-Pin) Connector Pin Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-4 C-1 Product Specifications for the DIGITAL MultiSwitch 612TX . . . . . . . . . . . . . . . . . . . . . . . . . C-2 C-2 Product Specifications for the Stack Director . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-3 C-3 Product Specifications for the Stack Station . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-4 C-4 Acoustical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-5 C-5 German Acoustical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-6 C-6 Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-7 xiii G-1 Alarm Table Entry Fields . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . G-6 G-2 Event Table Entries. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . G-7 xiv Preface Overview About this Manual This manual describes how to install, cable, and configure the DIGITAL MultiSwitch Hub 612TX in a DIGITAL MultiSwitch 600 System, or in a DIGITAL MultiSwitch 900 (formerly DEChub 900 MultiSwitch). The DIGITAL MultiSwitch Hub 612TX is a 12-port 100 Mb/s Fast Ethernet Hub. The module has eleven 8-pin MJ ports for 100BaseTX connections. The 12th port is provided by an optional Modular Media Interface (MM-100) that is installed in the module's expansion slot. An MM-100 provides either a 100BaseFX, 100BufFX or 100BaseTX port. The DIGITAL MultiSwitch Hub 612TX can be installed in a DIGITAL MultiSwitch 600 stack, or a DIGITAL MultiSwitch 900 chassis. Intended Audience This manual is intended for use by personnel who will install, set up, cable, and configure the DIGITAL MultiSwitch Hub 612TX in a DIGITAL MultiSwitch 900, or DIGITAL MultiSwitch 600 System (with Stack Director or Stack Station). xv Organization Organization This manual is organized as follows: Chapter/ Description Appendix Part I DIGITAL MultiSwitch Hub 612TX 1 Describes the features and front and back panels of the DIGITAL MultiSwitch Hub 612TX module, and the features of the DIGITAL MultiSwitch 600 system. 2 Provides instructions for installing the MM-100 cards. 3 Provides instructions for installing and cabling the DIGITAL MultiSwitch Hub 612TX module. 4 Provides instructions for configuring the DIGITAL MultiSwitch Hub 612TX in a DIGITAL MultiSwitch 600 System and a DIGITAL MultiSwitch 900. 5 Provides instructions for using clearVISN to manage the DIGITAL MultiSwitch Hub 612TX in a DIGITAL MultiSwitch 600 System and a DIGITAL MultiSwitch 900. 6 Provides instructions for removing the DIGITAL MultiSwitch Hub 612TX from a DIGITAL MultiSwitch 600 System or a DIGITAL MultiSwitch 900. Part II DIGITAL MultiSwitch 600 System 7 Provides an overview, describes features, and describes the front and back panels of the Stack Director and Stack Station. 8 Provides instructions for assembling the DIGITAL MultiSwitch 600 Stack Director and Stack Station. 9 Provides instructions for managing the DIGITAL MultiSwitch 600 System. 10 Provides instructions for removing or replacing a level from a DIGITAL MultiSwitch 600 System. xvi Organization Chapter/ Description Appendix Part III Reference Information A Provides installation-specific troubleshooting information using the LEDs. B Provides connector and pin assignment information. C Provides product specifications. D Lists product ordering options and defines the part list for the product. E Lists associated documents and provides ordering information. F Lists service and support information for the DIGITAL MultiSwitch Hub 612TX. G Describes how to access RMON groups. Glossary Provides a glossary of terms and acronyms. Index Provides an index for the manual. xvii Conventions Conventions This book uses the following conventions. Convention Desc ript ion Bold Type Indicates user input. Indicates system output. Monospaced Type Indicates that you press the Return Key. xviii Safety Safety Any warning or caution that appears in this manual is defined as follows: WARNI NG Contains information to prevent personal injury. CAUT ION Contains information to prevent damage to equipment. VORSICHT Enthlt Informationen, die beachtet werden mssen um den Benutzer vor Schaden zu bewahren. ACHTUN G Enthlt Informationen, die beachtet werden mssen um die Gerate vor Schaden zu bewahren. DANGER Signale les informations destines prvenir les accidents corporels. ATTENTION Signale les informations destines prvenir la dtrioration du matriel. AVISO Contiene informacin para evitar daos personales. PRECA UCIN Contiene informacin para evitar daos al equipo. xix Safety The cautions and warnings that must be observed for the hardware described in this manual are listed below in English, German, French, and Spanish. CAUTION This action deletes all configured settings and replaces them with factory default values. All configuration settings will be lost. ACHTUN G Bei diesem Vorgang werden alle Konfigurationseinstellungen gelscht und die Werkseinstellungen wieder eingesetzt. Alle Konfigurationsdaten gehen verloren. ATTENTION Cette action supprime tous les paramtres de configuration et les remplace par des valeurs prdfinies. Tous les paramtres de configuration seront perdus. PRECA UCIN Esta intervencin borrar todos los parmetros de configuracin y los sustituir por valores por defecto definidos de fbrica. Se perdern todos los parmetros de configuracin. WARNI NG Some fiber optic equipment can emit laser or infrared light that can injure your eyes. Never look into an optical fiber or connector port. Always assume the cable is connected to a light source. VORSICHT Bestimmte Lichtleitergerte knnen fr die Augen gefhrliches Laser- oder Infrarotlicht abstrahlen. Vermeiden Sie es daher unter allen Umstnden, direkt in ein Lichtleiterkabel oder einen Lichtleiteranschlu zu schauen. Gehen Sie immer davon aus, da Lichtleiterkabel mit einer Lichtquelle verbunden sind. DANGER Certains quipements fibre optique peuvent mettre un rayonnement laser ou infra-rouge pouvant provoquer des troubles oculaires. Ne regardez jamais l'intrieur d'une fibre optique ou d'un port de connecteur. Considrez que le cble est connect en permanence une source lumineuse. AVISO Ciertos equipos de fibras pticas pueden emitir luz lasrica o infrarroja con riesgos de lesiones en los ojos. No se debe nunca mirar en una fibra ptica o una puerta de conexin. Siempre hay que suponer que el cable est conectado a una fuente luminosa. xx Safety CAUT ION If power is interrupted during Stage 3 of the DLU process, the firmware image can become corrupted. Do not turn off power to the unit or perform any action that can cause the unit to lose power during Stage 3 of the DLU process. ACHTUN G Solite whrend der Phase 3 des DLU-Prozesses eine Unterbrechung der Stromversorgung eintreten, kann das Firmwareprogramm zerstrt verden. Aus diesem Grunde wird dringend empfohlen, Vorkehrungen zu treffen, da whrend der Durchfhrung dieser Phase 3 die Systemeinheit weder ausgeschaltet noch die Stromversorgung unterbrochen werden kann. ATTENTION L'image du microprogramme risque d'tre corrumpue, en cas de coupure de courant au cours de l'tape 3 du processus DLU. Ne mettez pas l'unit hors tension et n'excutez aucune action risquant d'entraner une coupure d'alimentation au course de cette tape. PRECA UCIN Si se interrumpe el suministro elctrico durante la Etapa 3 del proceso DLU,. puede daarse la imagen del firmware. No se debe apagar la unidad ni realizar ninguna operacin que pueda causar una interrupcin del suministro de la unidad durante la Etapa 3 del mencionado proceso. WARNI NG Always make sure this unit is adequately grounded. Do not connect more than five Stack Stations into a single power strip unless the power strip is protected by a GFCI device. VORSICHT Stellen Sie in jedem Falle sicher, da dieses Gert vorschrift- smig geerdet ist. An einen Stromversorgungskreis drfen nur dann mehr als fnf Stack Stations angeschlossen werden, wenn der Stromkreis durch einen Schutzschalter abgesichert ist. DANGER DANGER : vrifiez toujours que cette unit est correctement relie la terre. Ne connectez pas plus de cinq stations em- pilables sur une mme lisire lectrique, sauf si la lisire est protge par un dispositif GFCI. AVIS O ADVERTENCIA - Asegrese siempre de que esta unidad est puesta a tierra adecuadamente. No conecte ms de cinco estaciones en pila en una platina de alimentacin a menos que est protegida por un dispositivo GFCI. xxi Safety CAUT ION Static electricity can damage modules and electronic components. DIGITAL recommends using a grounded antistatic wrist strap and a grounded work surface when handling any modules. ACHTUNG Module und elektronische Komponenten knnen durch elektrostatische Entladungen beschdigt werden. Benutzen Sie immer eine antistatische Gelenkmanschette und eine geerdete Arbeitsunterlage, wenn Sie am offenen Gert arbeiten. ATTENTION Les charges excessives d'lectricit statique peuvent endommager les modules et les composants lectroniques. DIGITAL conseille l'utilisation d'un bracelet de masse et d'un plan de travail mis la terre lors de la manipulation des modules. PRECAUCION La electricidad esttica puede daar los componentes electrnicos y los mdulos. DIGITAL recomienda que se utilicen cintas de pasadores y superficies de trabajo conectadas a tierra al trabajar con cualquier mdulo. xxii Part I DIGITAL MultiSwitch Hub 612TX 100BufFX-MMF 100BaseFX-MMF DEXYM-BA DEXYM-AA DEXYU-AA 100BaseTX 1 2 3 MultiSwitch Hub 612TX Fast Ethernet DEXYU-AA 100BaseTX 1 2 3 4 5 6 7 8 9 10 11 12 12 1x 2x 3x 4x 5x 6x 7x 8x 9x 10x 11x NPB-0840-97F This illustration shows the DIGITAL MultiSwitch Hub 612TX module and its supported 100 Mb/s Fast Ethernet Modular Media Interfaces (MM-100s): the 100BaseFX, 100BufFX and 100BaseTX. The DIGITAL MultiSwitch Hub 612TX is a Class II Fast Ethernet hub. It can be installed in a DIGITAL MultiSwitch 600 System or in a DIGITAL MultiSwitch 900 chassis (formerly DEChub 900 MultiSwitch). Chapte r 1 Product Description Overview Introduction This chapter contains a technological overview of the DIGITAL MultiSwitch 600 System and a description of the DIGITAL MultiSwitch Hub 612TX. For detailed information about the DIGITAL MultiSwitch 600 System, refer to Part II. For additional information about the DIGITAL MultiSwitch 900 (formerly DEChub 900 MultiSwitch), refer to the DIGITAL MultiSwitch 900 Owner's Manual. In This Chapter Topic Page Network Topology for Class II Hubs to Switches with MMIs 1-2 Technology Overview 1-5 What Is the DIGITAL MultiSwitch 600 System? 1-6 DIGITAL MultiSwitch 600 System Features 1-8 Using DIGITAL MultiSwitch 600 System Modules in a DIGITAL 1-9 MultiSwitch 900 What Is the DIGITAL MultiSwitch Hub 612TX? 1-10 DIGITAL MultiSwitch Hub 612TX Features 1-11 MIB Support 1-12 Remote Monitoring (RMON) 1-12 DIGITAL MultiSwitch Hub 612TX Front Panel 1-13 DIGITAL MultiSwitch Hub 612TX Back Panel 1-14 Product Description 1-1 Network Topology for Class II Hubs to Switches with MMIs Network Topology for Class II Hubs to Switches with MMIs This section illustrates recommended network topologies. You should use these topologies when configuring your network with 100BaseFX, 100BaseTX, or 100BufFX Fast Ethernet cards. These 100Mb/s Fast Ethernet Modular Media Interface (MMI) cards are used in the DIGITAL Class II MultiSwitch 600 Fast Ethernet Hubs. The 100BufFX Fast Ethernet card allows FX buffered support for Fast Ethernet Hubs extending the cabling distance to 2 kilometers. Figure 1-1 shows a single Class II Hub configuration with a GIGAswitchFE (1) connected to a DIGITAL MultiSwitch Hub 612TX module (2). This connection is made using 100Mb/s Fast Ethernet Modular Media Cards. The combinations for connecting these cards are as follows: 100BaseFX Connects to another 100BaseFX card at a distance of up to 208 meters in half-duplex mode 100BaseTX Connects to another 100BaseTX card at a distance of up to 100 meters in half-duplex mode. 100BufFX Connects to another 100BaseFX card at a distance of up to 2 kilometers in full-duplex mode NOTE While a hub to hub configuration using two 100BufFX cards at a distance of up to 2 km will work, we do not recommend it. Figure 1-1: Single Class II Hub Configuration 1 FX or TX FX m m Km 8 0 20 10 2 FX or TX B Fast Ethernet 2 100 m 100 m 100 m NPB-0949A-97F 1-2 Product Description Network Topology for Class II Hubs to Switches with MMIs Figure 1-2 shows a primary and redundant Class II Hub configuration with a switch (1) connected to two DIGITAL MultiSwitch Hub 612TX modules (2) and (3). In this configuration, the 100BaseFX to 100BaseFX connection is at a distance of up to 111 meters. The 100BaseTX to 100BaseTX is 100 meters. The 100BufFX to 100BaseFX connection is up to 2 kilometers. This figure also shows the two Hub modules (2) and (3) connected via two 100BaseTX fixed ports using a 5 meter Inter-Repeater Link (IRL) in half-duplex mode. Figure 1-2: Two Class II Hub Configuration 1 FX or TX FX m m Km 0 1 10 11 2 IRL 5 m TX TX FX or TX B Fast Ethernet Fast Ethernet 2 3 100 m 100 m 100 m 100 m 100 m 100 m NPB-0947A-97F Auto-Negotiation The 100BufFX has a full duplex 100BaseFX interface and as such, does not auto- negotiate. You must manually configure the switch port to full duplex 100Base FX operation. Product Description 1-3 Network Topology for Class II Hubs to Switches with MMIs User Support Figure 1-3 shows user support for two configurations using primary link (1) and redundant link controlled by a switch that is configured appropriately (2) configurations. The configurations use DIGITAL MultiSwitch Hub 612TX (3) modules. Table 1-1 describes the number of users supported with each configuration. Figure 1-3: Various Class II Hub Configurations 2 2 1 1 Fast Ethernet Fast Ethernet Fast Ethernet 3 3 3 A B NPB-0948-97F Table 1-1: User Support for Various Class II Hub Configuration Configuration Module(s) Max imum Upli nk(s) Users A One DIGITAL MultiSwitch Hub 612TX 11 1 B Two DIGITAL MultiSwitch Hub 612TX 20-21 1-2 1-4 Product Description Technology Overview Technology Overview This section describes the technology you should be familiar with to use these products effectively. Ethernet Ethernet is a 10 Mb/s network communications system developed and standardized by DIGITAL, Intel, and Xerox. It uses baseband transmission, carrier sense multiple access with collision detection (CSMA/CD) access, and logical bus topology. This industry-standard protocol is specified by ISO 802-3 ANSI/IEEE Standard 802.3. Fast Ethernet Fast Ethernet is a 100 Mb/s extension to Ethernet and is standardized by ANSI/IEEE Standard 802.3. MAC frame formats and sizes are identical to those used by 10 Mb/s Ethernet. The Fast Ethernet standard includes the following subsets, collectively known as 100BaseX: 100BaseTX. A standard that specifies baseband operation over two pairs of
| 50-24214-01 74-51632-01 74-51644-01 AA-QX86B-TK AA-QX87B-TK AA-QX88B-TK EK-DEBAM-HR EK-DEHU2-IN EK-DH2MS-OM EK-DLMR2-IN EK-DLMR2-QS EK-DLMT1-IN EK-DLMT1-QS EK-DLMWL-IN EK-DLMWL-QS EK-DLSSM-IN EK-DLSSM-QS EK-MBITM-IM EK-NETWW-CM EK-SWTCH-HR PB-0947A-97 PB-0949A-97 QC-04RAA-GZ |