Product Details

ProLiant Clusters for SCO UnixWare 7 U/CL380 Quick Install Guide
First Edition (August 2000)
Part Number 189020-001
Compaq Computer Corporation
Compaq Confidential Need to Know Required
Writer: Hilary Stead Project: Compaq ProLiant Clusters for SCO UnixWare 7 U/CL380 Quick Install Guide Comments:
Part Number: 189020-001 File Name: a-frnt.doc Last Saved On: 7/27/00 1:06 PM
Notice
2000 Compaq Computer Corporation.
Compaq, NonStop, ProLiant, ROMPaq, SmartStart, Compaq Insight Manager, and the Compaq logo
Registered in U. S. Patent and Trademark Office. Microsoft, MS-DOS, Windows, and Windows NT are
trademarks of Microsoft Corporation. Intel and Pentium are trademarks of Intel Corporation. UNIX is a
trademark of The Open Group. All other product names mentioned herein may be trademarks of their
respective companies.
THE INFORMATION IN THIS PUBLICATION IS PROVIDED "AS IS" WITHOUT WARRANTY
OF ANY KIND. THE ENTIRE RISK ARISING OUT OF THE USE OF THIS INFORMATION
REMAINS WITH RECIPIENT. IN NO EVENT SHALL COMPAQ BE LIABLE FOR ANY DIRECT,
CONSEQUENTIAL, INCIDENTAL, SPECIAL, PUNITIVE OR OTHER DAMAGES
WHATSOEVER (INCLUDING WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS
PROFITS, BUSINESS INTERRUPTION OR LOSS OF BUSINESS INFORMATION), EVEN IF
COMPAQ HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES AND WHETHER
IN AN ACTION OF CONTRACT OR TORT, INCLUDING NEGLIGENCE.
The limited warranties for Compaq products are exclusively set forth in the documentation
accompanying such products. Nothing herein should be construed as constituting a further or
additional warranty.
Compaq ProLiant Clusters for SCO UnixWare 7 U/CL380 Quick Install Guide
First Edition (August 2000)
Part Number 189020-001
Compaq Confidential Need to Know Required
Writer: Hilary Stead Project: Compaq ProLiant Clusters for SCO UnixWare 7 U/CL380 Quick Install Guide Comments:
Part Number: 189020-001 File Name: a-frnt.doc Last Saved On: 7/27/00 1:06 PM
Contents
About This Guide
Text Conventions.......................................................................................................vii
Symbols in Text....................................................................................................... viii
Symbols on Equipment............................................................................................ viii
Getting Help ................................................................................................................ x
Compaq Technical Support .................................................................................. x
Compaq Website...................................................................................................x
Compaq Authorized Reseller...............................................................................xi
Chapter 1
Introducing Compaq ProLiant Clusters for SCO UnixWare 7 U/CL380
Overview of Compaq ProLiant Clusters for UnixWare 7........................................ 1-1
Cluster Configuration .............................................................................................. 1-2
Compaq ProLiant CL380......................................................................................... 1-3
Cluster Integrity Serial Cable .................................................................................. 1-4
Cluster Interconnect................................................................................................. 1-5
Local Area Network Connection ............................................................................. 1-5
SCO UnixWare Software......................................................................................... 1-6
Compaq Software .................................................................................................... 1-6
Compaq ProLiant Clusters for SCO UnixWare 7 Quick Install CDs ............... 1-7
Compaq SmartStart and Support Software CD ................................................ 1-8
Compaq Management CD ................................................................................ 1-8
Resources for Application Installation..................................................................... 1-9
Compaq Confidential Need to Know Required
Writer: Hilary Stead Project: Compaq ProLiant Clusters for SCO UnixWare 7 U/CL380 Quick Install Guide Comments:
Part Number: 189020-001 File Name: a-frnt.doc Last Saved On: 7/27/00 1:06 PM
iv Compaq ProLiant Clusters for SCO UnixWare 7 U/CL380 Quick Install Guide
Chapter 2
Setting Up Hardware for the Compaq ProLiant Clusters for SCO UnixWare 7
U/CL380
Setting Up Components ........................................................................................... 2-1
Setting Up the Nodes ........................................................................................ 2-2
Setting Up the Shared Storage .......................................................................... 2-2
Cabling the Components.......................................................................................... 2-2
Using Labeling Standards ................................................................................. 2-3
Connecting the Cluster Integrity Serial Cable .................................................. 2-3
Cabling the Keyboard, Monitor, and Mouse..................................................... 2-3
Chapter 3
Installing Software Using the Compaq ProLiant Clusters for SCO UnixWare 7
U/CL380 Quick Install CDs
Preinstallation Tasks and Considerations................................................................. 3-2
Obtaining UnixWare 7 Licenses .............................................................................. 3-2
Configuring the Servers with SmartStart ................................................................. 3-3
Installing the Cluster with Quick Install .................................................................. 3-5
Installing the First Node.................................................................................... 3-6
Installing the Second Node ............................................................................... 3-8
Verifying Cluster Assembly and Installation ........................................................... 3-8
Registering the Compaq ProLiant Cluster for SCO UnixWare 7............................. 3-9
Chapter 4
Managing Compaq ProLiant Clusters for SCO UnixWare 7 U/CL380
TM
SCO UnixWare 7 NonStop Clusters Management Software ................................ 4-2
Clusterized SCOadmin...................................................................................... 4-2
Event Processing Subsystem............................................................................. 4-3
TM
NonStop Cluster Management Suite.............................................................. 4-3
SCO Clusterized Commands ............................................................................ 4-4
Compaq ProLiant Cluster Management Software for SCO UnixWare 7
TM
NonStop Clusters .................................................................................................. 4-6
Compaq Insight Manager Support .................................................................... 4-6
Compaq Insight Manager XE Support.............................................................. 4-7
UPS-Initiated Shutdown, Configuration, and Setup ......................................... 4-8
Compaq Confidential Need to Know Required
Writer: Hilary Stead Project: Compaq ProLiant Clusters for SCO UnixWare 7 U/CL380 Quick Install Guide Comments:
Part Number: 189020-001 File Name: a-frnt.doc Last Saved On: 7/27/00 1:06 PM
Contents v
Chapter 5
Troubleshooting Compaq ProLiant Clusters for SCO UnixWare 7 U/CL380
Installation Problems ............................................................................................... 5-2
Quick Install Error Messages............................................................................ 5-3
Node-to-Node Communication Problems ........................................................ 5-4
Client-to-Cluster Connectivity Problems.......................................................... 5-5
Cluster Resource Problems............................................................................... 5-6
Appendix A
Software Versions
Appendix B
Quick Install Planning Worksheets
Glossary
Index
Compaq Confidential Need to Know Required
Writer: Hilary Stead Project: Compaq ProLiant Clusters for SCO UnixWare 7 U/CL380 Quick Install Guide Comments:
Part Number: 189020-001 File Name: a-frnt.doc Last Saved On: 7/27/00 1:06 PM
About This Guide
This guide is designed to be used as step-by-step instructions for installation
and as a reference for operation and troubleshooting.
Text Conventions
This document uses the following conventions to distinguish elements of text:
Keys Keys appear in boldface. A plus sign (+) between
two keys indicates that they should be pressed
simultaneously.
User Input, Commands, User input, commands, and menu options appear in
and Menu options a different typeface.
File names, directory File names, directory names, and drive names
names, and drive names appear in lowercase.
Dialog Box Names These elements appear in initial capital letters.
Type When you are instructed to type information, type
the information without pressing the Enter key.
Enter When you are instructed to enter information, type
the information and then press the Enter key.
Compaq Confidential Need to Know Required
Writer: Hilary Stead Project: Compaq ProLiant Clusters for SCO UnixWare 7 U/CL380 Quick Install Guide Comments:
File Name: a-frnt.doc Last Saved On: 7/27/00 1:06 PM
viii Compaq ProLiant Clusters for SCO UnixWare 7 U/CL380 Quick Install Guide
Symbols in Text
These symbols may be found in the text of this guide. They have the following
meanings.
WARNING: Text set off in this manner indicates that failure to follow directions
in the warning could result in bodily harm or loss of life.
CAUTION: Text set off in this manner indicates that failure to follow directions
could result in damage to equipment or loss of information.
IMPORTANT: Text set off in this manner presents clarifying information or specific
instructions.
NOTE: Text set off in this manner presents commentary, sidelights, or interesting points
of information.
Symbols on Equipment
These symbols may be located on equipment in areas where hazardous
conditions may exist.
This symbol in conjunction with any of the following symbols indicates
the presence of a potential hazard. The potential for injury exists if
warnings are not observed. Consult your documentation for specific
details.
This symbol indicates the presence of hazardous energy circuits or
electric shock hazards. Refer all servicing to qualified personnel.
WARNING: To reduce the risk of injury from electric shock hazards, do
not open this enclosure. Refer all maintenance, upgrades, and
servicing to qualified personnel.
This symbol indicates the presence of electric shock hazards. The area
contains no user or field serviceable parts. Do not open for any reason.
WARNING: To reduce the risk of injury from electric shock hazards,
do not open this enclosure.
Compaq Confidential Need to Know Required
Writer: Hilary Stead Project: Compaq ProLiant Clusters for SCO UnixWare 7 U/CL380 Quick Install Guide Comments:
Part Number: 189020-001 File Name: a-frnt.doc Last Saved On: 7/27/00 1:06 PM
About This Guide ix
This symbol on an RJ-45 receptacle indicates a Network Interface
Connection.
WARNING: To reduce the risk of electric shock, fire, or damage to the
equipment, do not plug telephone or telecommunications connectors
into this receptacle.
This symbol indicates the presence of a hot surface or hot component.
If this surface is contacted, the potential for injury exists.
WARNING: To reduce the risk of injury from a hot component, allow
the surface to cool before touching.
These symbols on power supplies or systems indicate that the
equipment is supplied by multiple sources of power.
WARNING: To reduce the risk of injury from electric shock,
remove all power cords to completely disconnect power from
the system.
This symbol indicates that the component exceeds the
recommended weight for one individual to handle safely.
WARNING: To reduce the risk of personal injury or damage to the
equipment, observe local occupational health and safety
requirements and guidelines for manual material handling.
Compaq Confidential Need to Know Required
Writer: Hilary Stead Project: Compaq ProLiant Clusters for SCO UnixWare 7 U/CL380 Quick Install Guide Comments:
Part Number: 189020-001 File Name: a-frnt.doc Last Saved On: 7/27/00 1:06 PM
x Compaq ProLiant Clusters for SCO UnixWare 7 U/CL380 Quick Install Guide
Getting Help
If you have a problem that is not explained in this guide, you can get further
information and other help in the following locations.
Compaq Technical Support
In North America, call the Compaq Technical Phone Support Center at
1-800-OK-COMPAQ. This service is available 24 hours a day, 7 days a week.
For continuous quality improvement, calls may be recorded or monitored.
Outside North America, call the nearest Compaq Technical Support Phone
Center. Telephone numbers for worldwide Technical Support Centers are
listed on the Compaq website. Access the Compaq website by logging on to
the Internet at
http://www.compaq.com
Be sure to have the following information available before you call Compaq:
I Technical support registration number (if applicable)
I Product serial number
I Product model name and number
I Applicable error messages
I Add-on boards or hardware
I Third-party hardware or software
I Operating system type and revision level
Compaq Website
The Compaq website has information on this product and the latest drivers and
Flash ROM images. You can access the Compaq website by logging on to the
Internet at
http://www.compaq.com
Compaq Confidential Need to Know Required
Writer: Hilary Stead Project: Compaq ProLiant Clusters for SCO UnixWare 7 U/CL380 Quick Install Guide Comments:
Part Number: 189020-001 File Name: a-frnt.doc Last Saved On: 7/27/00 1:06 PM
About This Guide xi
Compaq Authorized Reseller
For the name of your nearest Compaq authorized reseller:
I In the United States, call 1-800-345-1518.
I In Canada, call 1-800-263-5868.
I Elsewhere, see the Compaq website for locations and telephone
numbers.
Compaq Confidential Need to Know Required
Writer: Hilary Stead Project: Compaq ProLiant Clusters for SCO UnixWare 7 U/CL380 Quick Install Guide Comments:
Part Number: 189020-001 File Name: a-frnt.doc Last Saved On: 7/27/00 1:06 PM
1
Chapter
Introducing Compaq ProLiant Clusters
for SCO UnixWare 7 U/CL380
This chapter introduces the Compaq ProLiant Clusters for SCO UnixWare 7
U/CL380 Quick Install. This chapter also identifies the components that make
up the cluster configuration.
Overview of Compaq ProLiant Clusters
for UnixWare 7
A cluster is a collection of servers and storage hardware and operating system
and management software, allowing independent servers and storage to act as
a single system. The cluster presents a single-system image to clients; provides
protection against hardware, operating system, middleware, and application
failures; and provides configuration options for load balancing.
Clustering is an established technology that provides benefits such as:
I Availability
I Scalability
I Manageability
I Investment protection
I Operational efficiency
Compaq Confidential Need to Know Required
Writer: Hilary Stead Project: Compaq ProLiant Clusters for SCO UnixWare 7 U/CL380 Quick Install Guide Comments:
Part Number: 189020-001 File Name: b-ch1 Architecture of Compaq ProLiant Clusters for SCO UnixWare 7.doc Last Saved On: 7/27/00 1:09 PM
1-2 Compaq ProLiant Clusters for SCO UnixWare 7 U/CL380 Quick Install Guide
TM
The reliability of the SCO UnixWare 7 NonStop Clusters technology
protects applications and data from multiple error conditions. For more details
on Compaq ProLiant Clusters for SCO UnixWare 7, see the Compaq High
Availability website at
http://www.compaq.com/highavailability
Cluster Configuration
The Compaq ProLiant Clusters for SCO UnixWare 7 U/CL380 Quick Install
cluster configuration requires various hardware and software components.
Hardware components include:
I One Compaq ProLiant CL380
I At least one internal 9.1-GB or greater hard drive per server node
I One Cluster Integrity (CI) serial cable (provided in the cluster kit)
I At least two 9.1-GB or greater hard drives installed in the shared
storage area
Software components include:
I SCO UnixWare 7.1.1 Media Kit (provided in the cluster kit)
TM
I SCO UnixWare 7 NonStop Clusters 7.1.1+IP Media Kit (provided in
the cluster kit)
I Compaq ProLiant Clusters for SCO UnixWare 7 Quick Install CDs
(provided in the cluster kit)
TM
I Compaq SmartStart and Support Software CD (provided with the
Compaq ProLiant CL380)
I Compaq Management CD (provided with the Compaq ProLiant CL380)
TM
NOTE: SCO UnixWare 7 and UnixWare 7 NonStop Clusters software licenses must be
purchased separately through a SCO reseller or distributor. To locate a convenient SCO
reseller or distributor in order to purchase licenses, see the SCO website at
http://www.sco.com.
Compaq Confidential Need to Know Required
Writer: Hilary Stead Project: Compaq ProLiant Clusters for SCO UnixWare 7 U/CL380 Quick Install Guide Comments:
Part Number: 189020-001 File Name: b-ch1 Architecture of Compaq ProLiant Clusters for SCO UnixWare 7.doc Last Saved On: 7/27/00 1:09 PM
Introducing Compaq ProLiant Clusters for SCO UnixWare 7 U/CL380 1-3
The Compaq ProLiant Clusters for SCO UnixWare 7 U/CL380 Kit
configuration supports one Compaq ProLiant CL380. Figure 1-1 illustrates the
configuration.
Shared
Storage
Area SERVER NODE 1
SERVER NODE 2
Node 1 CI Serial Cable
B
ACT / LINK
A
Node 2 B
ACT / LINK
A
Figure 1-1. Hardware components
Refer to the sections "Cluster Interconnect" and "Local Area Network
Connection" later in this chapter for more information on the cluster Ethernet
IP connections.
Compaq ProLiant CL380
The Compaq ProLiant CL380 consists of two Compaq server nodes and
shared storage prepackaged in a cabinet. The ProLiant CL380 contains the
latest Intel Pentium III processors and more than 200 GB of internal storage. It
TM
integrates with standard Compaq software, such as Compaq Insight Manager
and SmartStart for ease of installation and monitoring.
Standard features include:
I One processor and integrated 512-KB level 2 cache and one Processor
Power Module per server node
I 128 MB of memory per server node
I One 32-bit and three 64-bit expansion slots per server node
I Disk controllers
One Shared Storage RAID Controller CR3500 in the shared
storage area
One Dual-Channel Wide Ultra2 SCSI adapter in each server node
Compaq Confidential Need to Know Required
Writer: Hilary Stead Project: Compaq ProLiant Clusters for SCO UnixWare 7 U/CL380 Quick Install Guide Comments:
Part Number: 189020-001 File Name: b-ch1 Architecture of Compaq ProLiant Clusters for SCO UnixWare 7.doc Last Saved On: 7/27/00 1:09 PM
1-4 Compaq ProLiant Clusters for SCO UnixWare 7 U/CL380 Quick Install Guide
I One Compaq NC3163 embedded Fast Ethernet WOL on the PCI local
bus, and one Compaq NC3123 Fast Ethernet NIC PCI 10/100 WOL
controller in each server node
I Mass storage
System shared storage drive cage area supports up to six 1-inch
Wide Ultra2 SCSI drives.
Each server node supports up to six drives.
See the documentation that came with the Compaq ProLiant CL380 for more
information and a complete list of features.
Cluster Integrity Serial Cable
The CI serial cable is required to prevent a split-brain condition. Split-brain
occurs when both nodes in a two-node cluster try to operate as the root node.
Since the active root node mounts the root file system and runs several critical
cluster-wide functions, having two nodes trying to behave as the root node is
undesirable.
NOTE: The CI serial cable may be referred to as the split-brain avoidance (SBA) serial
cable in UnixWare software and documentation.
Compaq Confidential Need to Know Required
Writer: Hilary Stead Project: Compaq ProLiant Clusters for SCO UnixWare 7 U/CL380 Quick Install Guide Comments:
Part Number: 189020-001 File Name: b-ch1 Architecture of Compaq ProLiant Clusters for SCO UnixWare 7.doc Last Saved On: 7/27/00 1:09 PM
Introducing Compaq ProLiant Clusters for SCO UnixWare 7 U/CL380 1-5
Cluster Interconnect
A Compaq NC3163 Fast Ethernet WOL NIC is embedded in the motherboard
of each server node in the Compaq ProLiant CL380. This NIC enables the
cluster interconnect, which is precabled in the ProLiant CL380.
NOTE: The cluster interconnect may be referred to as the cluster heartbeat cable in
ProLiant CL380 documentation.
The cluster nodes use the cluster interconnect to support the single-system
image capabilities of the cluster, including:
I Cluster-wide file system
I Cluster-wide process management, migration, and load balancing
I Cluster-wide networking and Cluster Virtual IP (CVIP)
I Cluster-wide system administration and management
Refer to the documentation that came with the Compaq ProLiant CL380 for
more information on the cluster interconnect.
Local Area Network Connection
A Compaq NC3123 Fast Ethernet NIC PCI 10/100 WOL NIC comes
preinstalled in slot 1 of each server node in the Compaq ProLiant CL380.
These NICs enable the cluster to access a public local area network (LAN) and
must be on a subnet different from the embedded Ethernet cluster interconnect.
Multiple public LAN controllers can be installed after Quick Install is
complete. For a list of certified NICs, see the Compaq High Availability
website at
http://www.compaq.com/highavailability
Refer to the documentation that came with the Compaq ProLiant CL380 for
more information on LAN connections.
Compaq Confidential Need to Know Required
Writer: Hilary Stead Project: Compaq ProLiant Clusters for SCO UnixWare 7 U/CL380 Quick Install Guide Comments:
Part Number: 189020-001 File Name: b-ch1 Architecture of Compaq ProLiant Clusters for SCO UnixWare 7.doc Last Saved On: 7/27/00 1:09 PM
1-6 Compaq ProLiant Clusters for SCO UnixWare 7 U/CL380 Quick Install Guide
SCO UnixWare Software
TM
SCO UnixWare 7 and the SCO UnixWare 7 NonStop Clusters software
provide the operating environment for the Compaq ProLiant Clusters for
TM
SCO UnixWare 7. The UnixWare 7 NonStop Clusters software provides the
technology to:
I Perform single-system-image operations
I Perform failover
I Define and modify cluster members
I Manually control and administer the cluster
I View the current state of the cluster
The SCO UnixWare software is included in the Compaq ProLiant Clusters for
SCO UnixWare 7 U/CL380 Kit.
TM
NOTE: SCO UnixWare 7.1.1+IP NonStop Clusters software only runs on
SCO UnixWare 7.1.1. Earlier versions of UnixWare are not supported.
TM
NOTE: SCO UnixWare 7 and UnixWare 7 NonStop Clusters software licenses must be
purchased separately through a SCO reseller or distributor. To locate a SCO reseller or
distributor, see the SCO website at http://www.sco.com.
Compaq Software
Compaq offers a set of features and optional tools to support the configuration
and management of Compaq ProLiant Clusters for SCO UnixWare 7:
I Compaq ProLiant Clusters for SCO UnixWare 7 Quick Install
Image CDs
I Compaq SmartStart and Support Software CD
I Compaq Management CD
Compaq Confidential Need to Know Required
Writer: Hilary Stead Project: Compaq ProLiant Clusters for SCO UnixWare 7 U/CL380 Quick Install Guide Comments:
Part Number: 189020-001 File Name: b-ch1 Architecture of Compaq ProLiant Clusters for SCO UnixWare 7.doc Last Saved On: 7/27/00 1:09 PM
Introducing Compaq ProLiant Clusters for SCO UnixWare 7 U/CL380 1-7
Compaq ProLiant Clusters for SCO UnixWare 7
Quick Install CDs
The Compaq ProLiant Clusters for SCO UnixWare 7 Quick Install CDs
provide rapid and simplified cluster installation. These CDs contain the
necessary software configured for immediate cluster boot. An installation
wizard allows you to enter parameters and licenses specific to your
configuration.
TM
The Quick Install CDs also include the NonStop Cluster Verification Utility
(NSCVU) and the UPS-initiated shutdown software (NSCUPS).
NonStopTM Cluster Verification Utility
The NSCVU installs automatically during the cluster Quick Install. NSCVU
validates several key aspects of the Compaq ProLiant Clusters for SCO
UnixWare 7 and their components.
NSCVU is run from any node of a fully installed Compaq ProLiant Cluster for
SCO UnixWare 7. NSCVU conducts system software tests to verify that
TM
SCO UnixWare 7 and UnixWare 7 NonStop Clusters are correctly installed.
Refer to the nscvu(1M) manual page for more information on running NSCVU.
This manual page is viewable with the man(1M) command from the command
line or from within the SCOhelp online documentation set.
UPS-Initiated Shutdown Software
NSCUPS installs automatically during the cluster Quick Install. NSCUPS
provides a graceful shutdown of the cluster when a specified amount of battery
backup time is left.
Compaq Confidential Need to Know Required
Writer: Hilary Stead Project: Compaq ProLiant Clusters for SCO UnixWare 7 U/CL380 Quick Install Guide Comments:
Part Number: 189020-001 File Name: b-ch1 Architecture of Compaq ProLiant Clusters for SCO UnixWare 7.doc Last Saved On: 7/27/00 1:09 PM
1-8 Compaq ProLiant Clusters for SCO UnixWare 7 U/CL380 Quick Install Guide
Compaq SmartStart and Support Software CD
Compaq SmartStart is located on the SmartStart and Support Software CD
shipped with Compaq ProLiant servers. Use the SmartStart step-by-step
process to configure the servers before using the Quick Install CDs. For
information concerning SmartStart, refer to the Compaq Server Setup and
Management pack that came with your server.
Options ROMPaq Utility
TM
The SmartStart and Support Software CD contains the Options ROMPaq
utility. Options ROMPaq updates the firmware on the hard drives.
Compaq Management CD
Compaq Insight Manager is located on the Compaq Management CD shipped
with Compaq ProLiant servers. Compaq Insight Manager is an easy-to-use,
console-based software utility for collecting server and cluster information.
Compaq Insight Manager performs the following functions:
I Monitors fault conditions and system status
I Monitors shared storage and interconnect adapters
I Forwards server alert fault conditions
I Remotely controls servers
In Compaq servers, each hardware subsystem, such as disk storage, system
memory, and system processor, has a robust set of management capabilities.
Compaq Insight Manager notifies the system administrator of impending fault
conditions and keeps the server up and running in the unlikely event of a
hardware failure.
The Compaq Management Agents are automatically installed during the
Quick Install.
Refer to the Compaq Server Setup and Management package for more
information about Compaq Insight Manager.
Compaq Confidential Need to Know Required
Writer: Hilary Stead Project: Compaq ProLiant Clusters for SCO UnixWare 7 U/CL380 Quick Install Guide Comments:
Part Number: 189020-001 File Name: b-ch1 Architecture of Compaq ProLiant Clusters for SCO UnixWare 7.doc Last Saved On: 7/27/00 1:09 PM
Introducing Compaq ProLiant Clusters for SCO UnixWare 7 U/CL380 1-9
Resources for Application Installation
The client/server software applications are among the key components of any
cluster. Compaq is working with its key software partners to ensure that
cluster-aware applications are available and that the applications work
seamlessly on Compaq ProLiant Clusters for SCO UnixWare 7.
Compaq white papers provide information about installing applications in
Compaq ProLiant Clusters for SCO UnixWare 7. Visit the Compaq High
Availability website to download cluster-related white papers and other
technical documents at
http://www.compaq.com/highavailability
IMPORTANT: Some software applications may need to be updated to take full advantage
of clustering. Contact the software vendors to check whether their software supports SCO
TM
UnixWare 7 NonStop Clusters and to ask whether any patches or updates are available
TM
for SCO UnixWare 7 NonStop Clusters operation.
Compaq Confidential Need to Know Required
Writer: Hilary Stead Project: Compaq ProLiant Clusters for SCO UnixWare 7 U/CL380 Quick Install Guide Comments:
Part Number: 189020-001 File Name: b-ch1 Architecture of Compaq ProLiant Clusters for SCO UnixWare 7.doc Last Saved On: 7/27/00 1:09 PM
2
Chapter
Setting Up Hardware for the
Compaq ProLiant Clusters for
SCO UnixWare 7 U/CL380
Use the following sections to set up the cluster hardware:
I Setting Up Components
I Cabling the Components
For specific information about individual components, see the documentation
that came with the component. For information on steps and procedures for
setting up cluster hardware, refer to the documentation that came with the
hardware.
Setting Up Components
The first step in setting up a cluster is to prepare the hardware components of
the cluster, including the servers used as nodes in the cluster.
Compaq Confidential Need to Know Required
Writer: Hilary Stead Project: Compaq ProLiant Clusters for SCO UnixWare 7 U/CL380 Quick Install Guide Comments:
Part Number: 189020-001 File Name: c-ch2 Setting Up Compaq ProLiant Clusters for SCO UnixWare 7.doc Last Saved On: 7/27/00 1:10 PM
2-2 Compaq ProLiant Clusters for SCO UnixWare 7 U/CL380 Quick Install Guide
Setting Up the Nodes
Setting up the cluster nodes includes installing processors, memory, and disk
drives. Node setup also includes installing any other approved NICs.
To install processors, memory, disk drives, tape drives, and other NICs, refer
to the Compaq documentation that came with these devices and the
documentation that came with the Compaq ProLiant CL380. For a list of
certified options, see the Compaq High Availability website at
http://www.compaq.com/highavailability
When setting up the nodes, keep in mind:
I A 9.1-GB or greater hard drive must be installed in slot 0 of each server
node.
I The two nodes must be identical in terms of server model, NICs,
processor type and speed, and system memory.
I Additional options, such as tape drives, other NICs, and Remote Insight
Boards, must be installed after cluster Quick Install.
Setting Up the Shared Storage
Setting up the shared storage includes installing disk drives and an optional,
redundant CR3500 RAID controller. To install these items, refer to the
Compaq documentation that came with these devices and the documentation
that came with the Compaq ProLiant CL380. For a full list of certified storage
options, see the Compaq High Availability website at
http://www.compaq.com/highavailability
When setting up the shared storage, keep in mind that at least two 9.1-GB or
greater hard drives must be installed.
Cabling the Components
Proper cabling can simplify service and assembly of the cluster. Following
appropriate cabling standards is vital to a successful cluster setup.
Compaq Confidential Need to Know Required
Writer: Hilary Stead Project: Compaq ProLiant Clusters for SCO UnixWare 7 U/CL380 Quick Install Guide Comments:
Part Number: 189020-001 File Name: c-ch2 Setting Up Compaq ProLiant Clusters for SCO UnixWare 7.doc Last Saved On: 7/27/00 1:10 PM
Setting Up Hardware for the Compaq ProLiant Clusters for SCO UnixWare 7 U/CL380 2-3
Using Labeling Standards
Proper labeling can prevent improper connections and simplify cluster
assembly and service. Make sure to label each server with the correct node
labels that are provided.
Also label both ends of the following cables:
I Cluster Integrity (CI) serial cable
I Keyboard, monitor, and mouse cables
I Server power cables
Each label should identify the server node to which the cable connects.
Connecting the Cluster Integrity Serial Cable
To cable the CI serial cable, connect one end of the CI serial cable to serial
port connector B on node 1. Connect the other end of the CI serial cable to
serial port connector B on node 2. Figure 2-1 illustrates proper cabling.
SERVER NODE 1
SERVER NODE 2
CI Serial Cable
B
ACT / LINK
A
B
ACT / LINK
A
Figure 2-1. Connecting the CI serial cable
Cabling the Keyboard, Monitor, and Mouse
To cable the keyboard, monitor, and mouse, refer to the documentation that
came with these devices.
Compaq Confidential Need to Know Required
Writer: Hilary Stead Project: Compaq ProLiant Clusters for SCO UnixWare 7 U/CL380 Quick Install Guide Comments:
Part Number: 189020-001 File Name: c-ch2 Setting Up Compaq ProLiant Clusters for SCO UnixWare 7.doc Last Saved On: 7/27/00 1:10 PM
3
Chapter
Installing Software Using the
Compaq ProLiant Clusters for
SCO UnixWare 7 U/CL380
Quick Install CDs
TM
Installing the SCO UnixWare 7 NonStop Clusters Quick Install on a
Compaq ProLiant Cluster includes several tasks. Use the following guidelines
for installation:
I Preinstallation Tasks and Considerations
I Obtaining UnixWare 7 Licenses
I Configuring the Server Nodes with SmartStart
I Installing the Cluster with Quick Install
I Verifying Cluster Assembly and Installation
I Registering the Compaq ProLiant Cluster for SCO UnixWare 7
For specific information about individual software components, see the
documentation that came with the component.
Compaq Confidential Need to Know Required
Writer: Hilary Stead Project: Compaq ProLiant Clusters for SCO UnixWare 7 U/CL380 Quick Install Guide Comments:
Part Number: 189020-001 File Name: d-ch3 Installing Quick Reference on Compaq ProLiant Clusters for SCO UnixWare 7.doc Last Saved
On: 7/27/00 1:10 PM
3-2 Compaq ProLiant Clusters for SCO UnixWare 7 U/CL380 Quick Install Guide
Preinstallation Tasks and Considerations
Before beginning the software installation:
I Assemble the hardware for the cluster.
I Fill out the Quick Install planning worksheets in Appendix B of this
guide.
I Have one formatted diskette on hand.
I Read through this chapter to become familiar with the installation
procedures.
Table 3-1 lists the default settings used during the Quick Install. You can
modify these parameters after Quick Install is complete by running the
International Settings Manager in the System folder of SCOadmin.
Table 3-1
Quick Install Default Settings
Parameter Default
Locale C Standard
Keyboard United States C
Code Set C
Time Zone Configurable to any US time zone
Use SCOadmin to configure name servers for the cluster's domain name after
Quick Install is complete.
Obtaining UnixWare 7 Licenses
TM
Before loading and installing the SCO UnixWare 7 NonStop Cluster, obtain
a UnixWare 7 license. To locate a convenient SCO reseller or distributor in
order to purchase licenses, see the SCO website at
http://www.sco.com
Compaq Confidential Need to Know Required
Writer: Hilary Stead Project: Compaq ProLiant Clusters for SCO UnixWare 7 U/CL380 Quick Install Guide Comments:
Part Number: 189020-001 File Name: d-ch3 Installing Quick Reference on Compaq ProLiant Clusters for SCO UnixWare 7.doc Last Saved
On: 7/27/00 1:10 PM
Installing Software Using the Compaq ProLiant Clusters for SCO UnixWare 7 U/CL380 Quick Install CDs 3-3
Configuring the Servers with SmartStart
Before cluster installation, use the SmartStart CD that came with the Compaq
ProLiant CL380 to erase the existing configuration on both server nodes,
configure the server nodes, and set the SCSI ID of the host adapter for the
shared storage.
To erase the configuration:
CAUTION: This procedure erases any information currently stored on the server
node. To prevent information loss, back up important files before attempting
installation.
NOTE: SmartStart may prompt you for the Server Profile Diskette that came with the
server. If prompted, insert the diskette and follow the on-screen instructions.
1. Power up server node 1.
2. Insert the SmartStart CD in the CD-ROM drive for node 1 and wait for
SmartStart to boot.
3. Select the language. The Regional Settings screen displays.
4. Click Next, then click Continue. The license agreement displays.
5. Accept the license agreement to continue.
6. Select the Run System Erase Utility icon and click OK.
7. Click the Yes button when the System Erase Utility window displays.
8. Click the Yes button when prompted to continue.
To configure the server nodes:
1. Insert the SmartStart CD in the CD-ROM drive for node 1.
2. Press F1 when prompted and wait for SmartStart to boot.
3. Select the correct language.
4. Select the country and keyboard type.
5. Set the date and time, select the daylight savings time adjustment if
applicable, and click Next.
6. Click Continue.
7. Read the software license, select the I Agree check box, and click OK to
continue.
Compaq Confidential Need to Know Required
Writer: Hilary Stead Project: Compaq ProLiant Clusters for SCO UnixWare 7 U/CL380 Quick Install Guide Comments:
Part Number: 189020-001 File Name: d-ch3 Installing Quick Reference on Compaq ProLiant Clusters for SCO UnixWare 7.doc Last Saved
On: 7/27/00 1:10 PM
3-4 Compaq ProLiant Clusters for SCO UnixWare 7 U/CL380 Quick Install Guide
8. Select the Manual Configuration installation path and click the Begin button.
9. Select SCO from the menu.
10. Select SCO UnixWare 7.1.1 and click Next.
11. Click Continue. Wait while the system configuration loads.
12. Select Save configuration and press Enter.
13. Select Continue with SmartStart and press Enter.
14. Select OK and press Enter. Wait while the Array Configuration Utility
loads.
15. Click Next at the Unconfigured Controller screen,
16. Select UnixWare/Linux and click Next.
17. Select RAID 0 and click Next.
18. Click Next at the Preview Configuration screen.
19. Click the Save Configuration Now button.
20. Select Controller->Exit from the menu bar and wait while the system
partition installation completes. The server reboots and the Create
Support Software window displays.
21. Click Next. The Release Notes window displays.
22. Click Continue to reboot the node from the SmartStart CD.
To set the SCSI ID of the host adapter for the shared storage:
1. Select Run System Configuration Utility and click OK. Wait while the
configuration loads.
2. Select Review or modify hardware settings and press Enter.
3. Select Step 3: View or edit details and press Enter.
4. Page down to Slot 2--Compaq 64-bit Dual Channel Wide Ultra2 SCSI Controller
(Port 1). Select SCSI ID and press Enter to modify the values.
5. Select the appropriate SCSI ID (7 for node 1, or 6 for node 2). Press F10
to continue.
6. Press F10 to exit the System Configuration Utility. Select Step 5: Save and
exit, then press Enter.
7. Select Save the configuration and restart the computer, then press Enter.
Compaq Confidential Need to Know Required
Writer: Hilary Stead Project: Compaq ProLiant Clusters for SCO UnixWare 7 U/CL380 Quick Install Guide Comments:
Part Number: 189020-001 File Name: d-ch3 Installing Quick Reference on Compaq ProLiant Clusters for SCO UnixWare 7.doc Last Saved
On: 7/27/00 1:10 PM
Installing Software Using the Compaq ProLiant Clusters for SCO UnixWare 7 U/CL380 Quick Install CDs 3-5
8. Remove the SmartStart CD from the CD-ROM drive and press Enter
when prompted.
Repeat the procedures for erasing the configuration, configuring the server
nodes, and setting the SCSI IDs for server node 2.
Installing the Cluster with Quick Install
Have the Quick Install planning worksheets in Appendix B filled out and on
hand before beginning the software installation. Have the following items
available:
I Cluster name and CVIP address
I Node 1 hostname and IP address for the public network
I Node 2 hostname and IP address for the public network
I Node 1 hostname and IP address for the cluster interconnect
I Node 2 hostname and IP address for the cluster interconnect
CAUTION: The public network IP addresses for node 1 and node 2 must be on
the same Ethernet subnet as the CVIP address. The cluster interconnect IP
addresses for node 1 and node 2 must be on a subnet different from the public
network.
TM
I UnixWare and NonStop Clusters licenses
I Passwords and system owner information
TM
I NonStop Clusters SNMP agent configuration information
I One formatted diskette
Compaq Confidential Need to Know Required
Writer: Hilary Stead Project: Compaq ProLiant Clusters for SCO UnixWare 7 U/CL380 Quick Install Guide Comments:
Part Number: 189020-001 File Name: d-ch3 Installing Quick Reference on Compaq ProLiant Clusters for SCO UnixWare 7.doc Last Saved
On: 7/27/00 1:10 PM
3-6 Compaq ProLiant Clusters for SCO UnixWare 7 U/CL380 Quick Install Guide
Installing the First Node
To install the software on the first node:
1. Power up node 1 and insert the Quick Install CD in the CD-ROM drive
of node 1. Wait while node 1 boots from the CD. A warning displays
indicating that data will be lost.
2. Press Enter to continue, or power off the system to abort the
installation.
The software begins to load and a progress bar displays indicating the
installation progress. When all the software has been loaded, several
screens display requesting necessary information.
3. Provide the necessary information for the following screens. Each
screen displays the fields and a brief description of each field as it is
selected for entry. For detailed help, press F1.
a. Screen 1: Read responses from previously saved diskette?
This screen gives the opportunity to restore responses from a
previous installation.
Enter No to save responses at a later time or if this is the first
installation. Responses can be saved later.
Enter Yes to read the answers from a diskette. The responses display
as defaults and can be changed at this time.
Enter Force to read the answers from a diskette and apply them
without modification. The responses do not display. (The date is
assumed to be correct on the system and is not modified.)
b. Screen 2: Date, Time, and Time Zone
Modify the current date, time, and time zone as necessary. Only US
time zones are available during Quick Install. Time zone information
can be changed after Quick Install by using the SCOadmin tools. For
more information, see "Preinstallation Tasks and Considerations."
c. Screen 3: Cluster name
Enter the name of the cluster.
d. Screen 4: System owner identity and passwords
Enter the full name of the system owner, the system owner login ID,
and the system owner and root passwords. (Passwords are not
displayed and must be repeated to verify that they are entered
correctly.)
Compaq Confidential Need to Know Required
Writer: Hilary Stead Project: Compaq ProLiant Clusters for SCO UnixWare 7 U/CL380 Quick Install Guide Comments:
Part Number: 189020-001 File Name: d-ch3 Installing Quick Reference on Compaq ProLiant Clusters for SCO UnixWare 7.doc Last Saved
On: 7/27/00 1:10 PM
Installing Software Using the Compaq ProLiant Clusters for SCO UnixWare 7 U/CL380 Quick Install CDs 3-7
e. Screen 5: IP interconnect
Enter the node 1 hostname and IP address for the cluster
interconnect, the node 2 hostname and IP address for the cluster
interconnect, and the netmask. The addresses must be on the same
network.
f. Screen 6: Public Network configuration
Enter the external network configuration: domain name, CVIP
address, netmask, node 1 hostname and IP address for the public
network, node 2 hostname and IP address for the public network,
and default route.
TM
g. Screen 7: NonStop Clusters SNMP agent configuration
TM
The NonStop Clusters SNMP agent configuration screen displays
the included SNMP configuration, which can be changed at this
tim e.
h. Screen 8: Save responses
Saving the responses can simplify later installations on this cluster or
similarly configured clusters. Responses can be saved, except for the
date, to a formatted diskette. Unencrypted passwords are not saved.
Remove the diskette from the diskette drive after saving the
responses.
4. A final screen displays indicating that the installation is complete.
5. Remove the Quick Install CD and press Enter to reboot node 1. The
SCOadmin license manager runs automatically.
6. Enter the node 1 UnixWare license, the node 2 UnixWare license, and
TM
the NonStop Clusters license. After this information is entered, the
node continues booting.
Compaq Confidential Need to Know Required
Writer: Hilary Stead Project: Compaq ProLiant Clusters for SCO UnixWare 7 U/CL380 Quick Install Guide Comments:
Part Number: 189020-001 File Name: d-ch3 Installing Quick Reference on Compaq ProLiant Clusters for SCO UnixWare 7.doc Last Saved
On: 7/27/00 1:10 PM
3-8 Compaq ProLiant Clusters for SCO UnixWare 7 U/CL380 Quick Install Guide
Installing the Second Node
To install the software on the second node:
IMPORTANT: Do not reboot node 2 until after the installation on node 1 is complete and
node 1 has been rebooted.
1. Power up node 2 and insert the Quick Install CD in the CD-ROM drive
of node 2. Wait while node 2 boots from the CD. A warning displays
indicating that data will be lost.
2. Press Enter to continue, or power down the system to abort the
installation.
The software begins to load and a progress bar displays indicating the
installation progress. When the software has been loaded, a screen
displays a request for the IP interconnect information.
3. Enter the IP interconnect address for node 1, the IP interconnect address
for node 2, and the netmask. The option to load or save this information
to a diskette is not available.
Wait until a message displays indicating that the installation is complete.
4. Remove the Quick Install CD and press Enter to reboot node 2.
Verifying Cluster Assembly
and Installation
After the cluster is fully assembled and installed, use the NSCVU to verify that
the cluster is assembled and installed properly. The NSCVU installs
automatically during Quick Install.
Run the nscvu command to verify that all of the cluster resources are present.
Resources include nodes, processors, memory, controllers, and storage units. If
any resources are missing or if file system failover is not operating correctly,
refer to Chapter 5 of this guide for troubleshooting help.
Compaq Confidential Need to Know Required
Writer: Hilary Stead Project: Compaq ProLiant Clusters for SCO UnixWare 7 U/CL380 Quick Install Guide Comments:
Part Number: 189020-001 File Name: d-ch3 Installing Quick Reference on Compaq ProLiant Clusters for SCO UnixWare 7.doc Last Saved
On: 7/27/00 1:10 PM
Installing Software Using the Compaq ProLiant Clusters for SCO UnixWare 7 U/CL380 Quick Install CDs 3-9
Registering the Compaq ProLiant Cluster
for SCO UnixWare 7
After the cluster is verified, go to the Compaq High Availability website to
register the cluster. Compaq sends notification to registered users as software
TM
updates and additional support for SCO UnixWare 7 NonStop Clusters is
made available. The website is located at
http://www.compaq.com/highavailability
Compaq Confidential Need to Know Required
Writer: Hilary Stead Project: Compaq ProLiant Clusters for SCO UnixWare 7 U/CL380 Quick Install Guide Comments:
Part Number: 189020-001 File Name: d-ch3 Installing Quick Reference on Compaq ProLiant Clusters for SCO UnixWare 7.doc Last Saved
On: 7/27/00 1:10 PM
4
Chapter
Managing Compaq ProLiant Clusters for
SCO UnixWare 7 U/CL380
Both Compaq and SCO provide management software to simplify the
management of Compaq ProLiant Clusters for SCO UnixWare 7. SCO cluster
management software includes:
I Clusterized SCOadmin
I Event Processor Subsystem
TM
I NonStop Cluster Management Suite
I Clusterized and cluster-specific command line utilities
Compaq provides the following management capabilities customized for use
with Compaq ProLiant Clusters for SCO UnixWare 7.
I Clusterized Compaq Insight Manager Support
I UPS-Initiated Shutdown Configuration
Compaq Confidential Need to Know Required
Writer: Hilary Stead Project: Compaq ProLiant Clusters for SCO UnixWare 7 U/CL380 Quick Install Guide Comments:
Part Number: 189020-001 File Name: e-ch4 Managing a Compaq ProLiant Cluster for SCO UnixWare 7.doc Last Saved On: 7/27/00 1:12 PM
4-2 Compaq ProLiant Clusters for SCO UnixWare 7 U/CL380 Quick Install Guide
TM
SCO UnixWare 7 NonStop Clusters
Management Software
The single-system image of the Compaq ProLiant Cluster makes managing a
cluster similar to managing a single-node non-cluster UnixWare 7 system.
Some procedures have been changed to support SCO UnixWare 7
TM
NonStop Clusters software. These changes are documented in the
TM
SCO UnixWare 7 NonStop Clusters System Administrator's Guide.
The following sections detail the management software included with Compaq
ProLiant Clusters for SCO UnixWare 7.
Clusterized SCOadmin
TM
The SCOadmin software provided with SCO UnixWare 7 NonStop Clusters
TM
has been clusterized for use in a NonStop Clusters environment. SCOadmin
is documented by help information available from within SCOadmin and by
TM
the online documentation supplied with SCO UnixWare 7 NonStop Clusters
software.
The SCOadmin software includes the following managers:
I Account Manager
I Filesystem Manager
I License Manager
I Login Session Viewer
I Mail Manager
I Netscape Server Administrator
I Print Job Manager
I Printer Setup Manager
I SCOadmin Setup Wizard
I Task Scheduler
I VERITAS Volume Manager
I Virtual Domain User Manager
Compaq Confidential Need to Know Required
Writer: Hilary Stead Project: Compaq ProLiant Clusters for SCO UnixWare 7 U/CL380 Quick Install Guide Comments:
Part Number: 189020-001 File Name: e-ch4 Managing a Compaq ProLiant Cluster for SCO UnixWare 7.doc Last Saved On: 7/27/00 1:12 PM
Managing Compaq ProLiant Clusters for SCO UnixWare 7 U/CL380 4-3
The following SCOadmin folders provide additional management tools:
I Clustering
I Compaq
I Hardware
I Networking
I Software Management
Event Processing Subsystem
The Event Processing Subsystem (EPS) is installed during cluster installation.
Use the EPS to configure actions and notifications based on system messages
TM
(syslogd). See the SCO UnixWare 7 NonStop Clusters System Administrator's
Guide for more information.
NonStopTM Cluster Management Suite
TM
The NonStop Cluster Management Suite (NCMS) is installed as part of SCO
TM
UnixWare 7 NonStop Clusters and includes:
I Keepalive Manager
I Keepalive Configuration Manager
I System Availability Monitor Viewer
I Configuration Manager
On the system, NCMS is started by entering the ncms command at a command
line prompt, or by selecting an application from the Clustering folder in the
SCOadmin management program.
Keepalive Manager
TM
The SCO UnixWare 7 NonStop Clusters Keepalive Manager provides a
graphical user interface to monitor the status of applications currently being
TM
managed by the Keepalive subsystem. See the SCO UnixWare 7 NonStop
Clusters System Administrator's Guide for more information on the Keepalive
subsystem.
Compaq Confidential Need to Know Required
Writer: Hilary Stead Project: Compaq ProLiant Clusters for SCO UnixWare 7 U/CL380 Quick Install Guide Comments:
Part Number: 189020-001 File Name: e-ch4 Managing a Compaq ProLiant Cluster for SCO UnixWare 7.doc Last Saved On: 7/27/00 1:12 PM
4-4 Compaq ProLiant Clusters for SCO UnixWare 7 U/CL380 Quick Install Guide
Keepalive Configuration Manager
TM
The SCO UnixWare 7 NonStop Clusters Keepalive Configuration Manager
provides a graphical user interface to create and manage configuration file sets
for applications to be monitored by the Keepalive subsystem. See the SCO
TM
UnixWare 7 NonStop Clusters System Administrator's Guide for more
information on the Keepalive Configuration Manager.
System Availability Monitor Viewer
TM
The SCO UnixWare 7 NonStop Clusters System Availability
Monitor (SAM) Viewer displays availability reports for the cluster and the
TM
cluster nodes. See the SCO UnixWare 7 NonStop Clusters System
Administrator's Guide for more information on the SAM Viewer.
Configuration Manager
TM
The SCO UnixWare 7 NonStop Clusters Configuration Manager provides a
graphical user interface to configure SNMP agents, the EPS, and Compaq
Insight Manager support. See the NCMS help subsystem for more information
TM
on the NonStop Clusters Configuration Manager.
SCO Clusterized Commands
TM
SCO UnixWare 7 NonStop Clusters software includes a number of
cluster-specific and clusterized commands to simplify system management in
a cluster environment. The following list identifies the key cluster-specific and
clusterized commands.
I onnode, onall--Executes a command on a specific node or on all nodes
I migrate, kill3--Sends the running process a migrate request signal
I cluster--Displays node state information and the software version
installed
I clusternode_avail--Shows node availability status
I clusternode_num--Displays the current node number
I where--Displays which node is currently serving a file, device, or
process
I spawndaemon--Registers processes for restart
I fast--Executes commands on the node with the smallest load
I fastnode--Returns the number of the node with the smallest load
Compaq Confidential Need to Know Required
Writer: Hilary Stead Project: Compaq ProLiant Clusters for SCO UnixWare 7 U/CL380 Quick Install Guide Comments:
Part Number: 189020-001 File Name: e-ch4 Managing a Compaq ProLiant Cluster for SCO UnixWare 7.doc Last Saved On: 7/27/00 1:12 PM
Managing Compaq ProLiant Clusters for SCO UnixWare 7 U/CL380 4-5
I clusternode_shutdown--Shuts down a specified node
I nodedown--Halts the specified node without processing
I dbms_guard--Runs the Data Base Management System guard
TM
I ncms--Runs the NonStop Cluster Management Suite
I ctsm--Runs the Cluster Time Sync Monitor
The SCO UnixWare commands that are clusterized in SCO UnixWare 7
TM
NonStop Clusters include:
I netstat, inetd, netcfg, rpcbind
I fuser, df, fsck, mknod, sync
I VERITAS commands, mount, umount, mountall, umountall
I init, crash, cron
I id tools, pdi commands
I pmd, brand
I SCOadmin commands
I sar, ps, ipcs, prtconf
I shutdown
The following SCO UnixWare commands interrogate the cluster node on
which they are executed. These commands can be used on any cluster node in
conjunction with the onnode command.
I nfsstat--NFS and RPC kernel interface statistics
I rtpm--Real-time performance monitor
I psradm--SMP processor administration
I psrinfo--SMP processor information
I pexbind--Exclusive processor bind operation
TM
NOTE: Refer to the SCO UnixWare 7 NonStop Clusters manual pages for more
information on SCO UnixWare commands.
Compaq Confidential Need to Know Required
Writer: Hilary Stead Project: Compaq ProLiant Clusters for SCO UnixWare 7 U/CL380 Quick Install Guide Comments:
Part Number: 189020-001 File Name: e-ch4 Managing a Compaq ProLiant Cluster for SCO UnixWare 7.doc Last Saved On: 7/27/00 1:12 PM
4-6 Compaq ProLiant Clusters for SCO UnixWare 7 U/CL380 Quick Install Guide
Compaq ProLiant Cluster Management
TM
Software for SCO UnixWare 7 NonStop
Clusters
Compaq provides the following cluster management capabilities customized
for use with Compaq ProLiant Clusters for SCO UnixWare 7:
I Compaq Insight Manager Support
I Compaq Insight Manager XE Support
I UPS-Initiated Shutdown Configuration
Compaq Insight Manager Support
Compaq Insight Manager client software runs on Win32 desktop computers
and remotely connects to the Compaq Management Agents running on a
UnixWare server or a Compaq ProLiant Cluster for SCO UnixWare 7. The
nodes within the cluster appear to Compaq Insight Manager as separate
UnixWare 7 systems.
Compaq Insight Manager Overview
Compaq Insight Manager is the Compaq console-based application for
managing networked devices. Compaq Insight Manager provides intelligent
monitoring and alerting capabilities for the critical systems in a distributed
enterprise.
Compaq Insight Manager consists of a console application and a set of server-
or client-based management data collection agents. Key subsystems are
designed to make system health, configuration, and performance data available
to the agent software. The agents act upon data by initiating SNMP alarms in
the event of faults and by providing updated management information.
Compaq Insight Manager is located on the Compaq Management CD. Install
Compaq Insight Manager on a Win32 desktop computer using the instructions
provided on the CD.
NOTE: Information on the Shared Storage RAID Controller CR3500 is only available
through the web-enabled agents used with Compaq Insight Manager XE.
Refer to the Compaq Insight Manager User Guide included on the Compaq
Management CD for more information on installing Compaq Insight Manager.
Compaq Confidential Need to Know Required
Writer: Hilary Stead Project: Compaq ProLiant Clusters for SCO UnixWare 7 U/CL380 Quick Install Guide Comments:
Part Number: 189020-001 File Name: e-ch4 Managing a Compaq ProLiant Cluster for SCO UnixWare 7.doc Last Saved On: 7/27/00 1:12 PM
Managing Compaq ProLiant Clusters for SCO UnixWare 7 U/CL380 4-7
Clusterized Compaq Management Agents
TM
Compaq Management Agents running on a SCO UnixWare 7 NonStop
Clusters system support the same client-server interface as is supported on a
single server SCO UnixWare 7 system. The client-server interface for Compaq
Insight Manager is SNMP-based, which allows ProLiant servers and clusters
to be managed by other network management client software.
The Compaq Management Agents are installed during the Quick Install and
are clusterized to allow proper operation within a Compaq ProLiant Cluster.
Each node has its own set of the clusterized agents. The agents on a specific
node are associated with the primary physical IP address of that node and
allow access to information regarding that node.
NOTE: The clusterized agents are only accessible through the primary physical IP address
for each node.
Compaq Insight Manager XE Support
Compaq Management Agent software runs on ProLiant Cluster servers and
interfaces to the Compaq Insight Manager XE management server using
SNMP and HTTP messaging. Compaq Insight Manager XE gives system
189020-001
Page 1 - Page 2 -

3prime solutions for all your HP requirements

     
 