Diagnostic Tools Utility Overview These utilities were developed to assist in diagnosing problems, testing the hardware, and monitoring and managing Compaq server hardware. Table 3-1 Diagnostic Tools Tool What it is How to run it Compaq Diagnostics Utility to assist testing and/or verifying Diagnostics and utilities are located on Program operation of Compaq hardware. If Compaq system partition on hard drive problems are found, Compaq and must be accessed when a system Diagnostics isolates failure(s) down to configuration error is detected during replaceable parts, whenever possible. Power-On Self-Test (POST). Compaq Diagnostics software is also available on the Compaq SmartStart and Support Software CD. A diagnostics diskette can be created from SmartStart and Support Software CD, and Diagnostics run from diskette. Compaq Inspect The Inspect utility provides a report The Inspect utility can be run from either Utility detailing system information. the main menu of the System Configuration Utility or the Compaq Diagnostics Program. Compaq Insight A client/server application used to For more information, refer to the Manager remotely manage Compaq hardware in Compaq Management CD and the a network environment. Reports Compaq Insight Manager User Guide. hardware fault conditions (both failure More information on viewing and printing and prefailure) and collects data for the event list can be found in the Compaq reporting and graphing. Insight Manager section of this chapter. Compaq Survey An online information gathering agent Install Survey from SmartStart, Compaq Utility that runs on servers, gathering critical Integration Maintenance Utility, or from hardware and software information Compaq Management CD. from various sources. A utility for servers running Windows NT or NetWare. If a significant change occurs between data-gathering intervals, previous information is marked, and the survey text file is overwritten to reflect the latest configuration and changes since last configuration. This allows a historical record of change events for server hardware and software. continued Diagnostics and Troubleshooting 3-3 Table 3-1 Diagnostic Tools continued Tool What it is How to run it Array Diagnostics A Windows-based tool designed to run Use the information provided in Array Utility (ADU) on all Compaq systems that support Diagnostics Utility (ADU) later in this Compaq array controllers. Two main chapter. functions of ADU are to collect all possible information about the array controllers in the system, and generate a list of detected problems. This tool is available for all Compaq servers covered by this guide. Drive Array The predecessor to ADU, DAAD is a For a list of Compaq servers still Advanced DOS-based tool for Compaq servers supported by this tool, visit the Compaq Diagnostics (DAAD) with Smart Array Controllers. DAAD website collects information about the array http://www.compaq.com controllers in the system and offers a list of detected problems. Integrated A log of system events, such as system The Integrated Management Log requires Management Log failures or nonfatal error conditions. Compaq operating system-dependent View events in the Integrated drivers. Refer to Compaq Support Management Log: Software CD for instructions on installing the appropriate drivers. On the Integrated Management
Display From within Compaq Insight
Manager From within Compaq Survey Utility
System Utility to easily configure the hardware If the server has bootable CD-ROM drive, Configuration Utility installed in or connected to the server. run Compaq System Configuration Utility Specifically, it can: directly from Support Software CD supplied with SMART Controller Option Resolve resource conflicts in areas Kit, or SmartStart and Support such as memory, port addresses, Software CD supplied with server. Use and interrupts (IRQs) the CD supplied for latest version supporting SMART Controller. Configure PCI boards automatically
If the server does not have a bootable Provide switch and jumper settings
CD-ROM drive, create diskettes with Manage installation of memory, latest version of the System processor upgrades, and mass Configuration Utility from Support storage devices such as hard Software CD, or SmartStart and Support drives, tape drives, and diskette Software CD. drives Store configuration information in
nonvolatile memory Assist in installation of an operating
system Assist in running diagnostic tools
such as TEST and INSPECT 3-4 Compaq ProLiant DL380 Maintenance and Service Guide Default Configuration When the system is first turned on, the system ROM detects the unconfigured state of the hardware and provides default configuration settings for most devices. By providing this initialization, the system can run Diagnostics and other software applications before running the normal SmartStart and System Configuration programs. Default Configuration Messages IMPORTANT: If you chose to format and partition the boot drive before running SmartStart and the System Configuration programs, this may prohibit creating a Compaq system partition and the off-line remote management features that it provides. If you insert a System Configuration, Diagnostics, or SmartStart and Support Software CD into the CD-ROM drive prior to powering on the Server, the system ROM boots to that utility. If the system ROM does not detect one of those CDs, you will be prompted for the intended operating system. The system reboots if any operating system-dependent configurations have changed with the new operating system selection. If the selected operating system-dependent configurations are the same as the current configurations, the system starts normally. If you enter a wrong choice, on subsequent restarts you may change the operating system. Inspect Utility The Inspect Utility provides configuration information such as the contents of the operating system startup files, the current memory configuration, the ROM version, and Integrated Management Log information. It operates with MS-DOS emulation mode of OS/2. Running the Inspect Utility 1. Turn the server off, then back on, then press F10 when the cursor appears in the upper right corner of the screen. 2. At the main menu, select Diagnostics and Utilities. 3. Press Enter. 4. Select Inspect Computer and press Enter. NOTE: If Diagnostics is not installed on the hard drive, System Configuration prompts you to insert the Diagnostics diskette in drive A. 5. Follow the instructions. Printing the Inspect Listing Select Print on the Inspect screen to print a copy of the Inspect listing. Keep a copy of the listing with each server for later reference. Diagnostics and Troubleshooting 3-5 Utilities Access The Compaq SmartStart and Support Software CD contains the SmartStart program and many of the Compaq utilities needed to maintain the system, including: System Configuration Utility
Array Configuration Utility
Array Diagnostic Utility
ROMPaq Firmware Upgrade Utilities
Compaq Diagnostics
CAUTION: Do not select the Erase Utility when running the SmartStart and Support Software CD. This will result in data loss to the entire system. Running Compaq Utilities There are three ways to access Compaq utilities: Running the Utilities on the Compaq System Partition If the system was installed using SmartStart, the Compaq utilities will automatically be available on the Compaq system partition. The Compaq system partition could also have been created during a manual system installation. To run the utilities on the Compaq system partition, start the system and press F10 when you see: Press F10 for Compaq system partition utilities. Then select the desired utility from the menu: The System Configuration Utility is available under the System Configuration menu.
The Array Configuration Utility is available under the System Configuration menu.
Compaq Diagnostics (Test and Inspect) are available under the Diagnostics and Utilities
menu. The ROMPaq Firmware Upgrade Utility is available under the Diagnostics and Utilities
menu. 3-6 Compaq ProLiant DL380 Maintenance and Service Guide Running the Utilities from Diskette Run the utilities from their individual diskettes. If you have a utility diskette newer than
the version on the SmartStart and Support Software CD, use that diskette. Create a diskette version of the utility from the SmartStart and Support Software CD.
To create diskette versions of the utilities from the CD: 1. Start the Compaq SmartStart and Support Software CD. 2. From the Compaq System Utilities screen, select Create Support Software Disks, then Next. 3. Select the diskette you would like to create from the list, then follow the instructions on the screen. Running the Utilities from the Compaq SmartStart and Support Software CD IMPORTANT: Only the System Configuration Utility and the Array Configuration Utility and the Array Diagnostic Utility can be executed from the Compaq SmartStart and Support Software CD. All other utilities must be executed from the Compaq system partition or from the diskette. To run these utilities directly from the Compaq SmartStart and Support Software CD: 1. Start the Compaq SmartStart and Support Software CD. 2. From the Compaq System Utilities screen, select the utility you wish to run, then select Next. G To execute the System Configuration Utility, select Run System Configuration Utility. G To execute the Array Configuration Utility, select Run Array Configuration Utility. G To execute the Array Diagnostic Utility, select Run Array Diagnostic Utility. Diagnostics and Troubleshooting 3-7 Power-On Self-Test (POST) POST is a series of diagnostic tests that run automatically on Compaq computers when the system is turned on. POST checks the following assemblies to ensure that the computer system is functioning properly: System ROM
Keyboard
Power supply
System board
Memory
Memory expansion boards
Controllers
Diskette drives
Hard drives
Processor Power Modules
Fans
POST Error Messages If POST finds an error in the system, an error condition is indicated by an audible and/or visual message. If an error code displays on the screen during POST or after resetting the system, use the instructions in the POST Error Messages table. NOTE: Many of the actions listed require you to run Diagnostics or the Compaq System Configuration Utility. Steps for running these utilities are provided following the POST Error Messages tables. The Recommended Action column lists the steps necessary to correct the problem. After completing each step, run the Diagnostics program to verify whether the error condition has been corrected. If the error code reappears, perform the next step, then run the Diagnostics program again. Follow this procedure until Diagnostics no longer detects an error condition. 3-8 Compaq ProLiant DL380 Maintenance and Service Guide Table 3-2 POST Error Messages Error Code Audible Beeps Probable Source of Problem Recommended Action A Critical Error None A catastrophic system error, Run Diagnostics. Replace failed assembly as indicated. occurred prior to this which caused the server to power-up crash, has been logged. Check documentation for Unsupported 1 long, 1 short Processor not supported by supported processors, and if Processor Detected current system ROM. supported, remove the System Halted processor and update the system to latest ROM. FATAL ROM ERROR: 1 long, 1 short ROM programmed in factory Replace the physical ROM part. The System ROM is incorrectly. not properly programmed 101-ROM Error 1 long, 1 short System ROM checksum Run Diagnostics. Replace failed assembly as indicated. 101-I/O ROM Error None Options ROM checksum Run Diagnostics. Replace failed assembly as indicated. None DMA, timers, and so on Replace the system board. Run 102-System Board the Compaq System Failure Configuration Utility. None System board failure Run Diagnostics. Replace failed 104-ASR-2 Timer assembly as indicated. Failure 162-System Options 2 short Configuration incorrect Run the System Configuration Not Set Utility and correct. 163-Time & Date Not 2 short Invalid time or date in Run the System Configuration Set configuration memory Utility and correct. 172-Configuration None Nonvolatile configuration corrupt Run the System Configuration Nonvolatile Memory or jumper installed Utility and correct. Invalid 177-Configuration None Incomplete system configuration Run the System Configuration Not Complete Utility and correct. continued Diagnostics and Troubleshooting 3-9 Table 3-2 POST Error Messages continued Error Code Audible Beeps Probable Source of Problem Recommended Action 178-Processor None Processor type or step does not Run the System Configuration Configuration Invalid match configuration memory. Utility and correct. 180-Log Reinitialized None N/A N/A 201-Memory Error None RAM failure Run Diagnostics. Replace failed assembly as indicated. 203-Memory None RAM failure Run Diagnostics. Replace failed Address Error assembly as indicated. 207-Invalid Memory None Memory module installed Verify placement of memory Configuration - incorrectly. modules. Check DIMM [SIMM] Installation 208-Invalid Memory The speed of the memory 1 long, 1 short The speed of the memory is too Speed - Check DIMM modules must be 60 ns. Verify slow: [SIMM] Installation the speed of the memory xx00 = expansion board modules installed and replace if SIMMs are too slow slower than 60 ns. 00yy = system board SIMMs
are too slow. xx and yy have a
corresponding bit set. 209-Memory 1 long, 1 short Unable to size memory Check DIMM installation and if Detection Failure. error persists, call Compaq Check Memory service provider. Installation 211-Cache Switch None Switch not set properly during Verify switch settings. Set Incorrectly installation or upgrade. 212-System 1 short Processor in slot x failed. Run Diagnostics and replace Processor Failed/ failed processor. Mapped out 214-DC-DC None PowerSafe Module (DC-DC Run Diagnostics. Replace failed Converter Failed Converter) failed. assembly as indicated. 214-Processor PPM None Indicated PPM (DC-DC Converter) Replace failed assembly as Failed Module X failed. indicated. continued 3-10 Compaq ProLiant DL380 Maintenance and Service Guide Table 3-2 POST Error Messages continued Error Code Audible Beeps Probable Source of Problem Recommended Action 215-Processor Power None PPM (DC-DC Converter) has lost Run Diagnostics. Replace failed Module has lost redundancy. assembly as indicated. Redundancy in Socket x 215-Nonfunctioning None PPM (DC-DC Converter) has Run Diagnostics. Replace failed Voltage Regulator failed or lost redundancy. assembly as indicated. Module for Processors 216-Voltage None Redundancy failed in PPM. To restore redundancy, replace Regulator Module for the PPM. Processor X no longer redundant 216-Processor PPM None Indicated PPM (DC-DC Converter) Replace failed assembly as has lost Redundancy, has lost redundancy. indicated. Module X 218-Cache None Cache Accelerators not installed Check Cache Accelerator Accelerators Not or improperly installed. installation. Installed. System Halted. 219-Tag Update None Catastrophic chipset failure. Call Compaq service provider. Rules SRAM Failure. System Halted 219-Snoop Rules None Catastrophic chipset failure. Call Compaq service provider. SRAM Failure. System Halted. 220-Cache None Cache Accelerator in slot x Check Cache Accelerator Accelerator Slot x improperly installed or bad. installation and if properly Initialization Failed. installed, replace. System Halted. 221-Power Fault On None A PPM on indicated bus is in a Run Diagnostics. Replace failed Processor Bus X failed state. assembly as indicated. 301-Keyboard Error None Keyboard failure Turn off the computer, then reconnect the keyboard. 301-Keyboard Error None Keyboard failure Replace the keyboard. or Test Fixture Installed ZZ-301-Keyboard None Keyboard failure. (ZZ represents 1. A key is stuck. Try to Error the Keyboard Scan Code.) free it. 2. Replace the keyboard. continued Diagnostics and Troubleshooting 3-11 Table 3-2 POST Error Messages continued Error Code Audible Beeps Probable Source of Problem Recommended Action 303-Keyboard None System board, keyboard, or 1. Run Diagnostics. Controller Error mouse controller failure 2. Replace failed assembly as indicated. 304-Keyboard or None Keyboard, keyboard cable, or 1. Make sure the keyboard is System Unit Error system board failure attached. 2. Run Diagnostics to determine which is in error. 3. Replace the part indicated. 40X-Parallel Port X 2 short Both external and internal ports Run the System Configuration Address Assignment are assigned to parallel port X. Utility and correct. Conflict 601-Diskette None Diskette controller circuitry 1. Make sure the diskette Controller Error failure drive cables are attached. 2. Replace the diskette drive and/or cable. 3. Replace the system board. 605-Diskette Drive 2 short Mismatch in drive type Run the System Configuration Type Error Utility to set diskette type correctly. 1151-Com Port 1 2 short Both external and internal serial Run the System Configuration Address Assignment ports are assigned to COM1. Utility and correct. Conflict 1152-Com Port 2, 3, 2 short Both external and internal serial Run the System Configuration or 4 Address ports are assigned to COM2, Utility and correct. Assignment Conflict COM3 or COM4. 1610-Temperature 2 short Ambient system temperature Check fan in system violation detected. too hot environment. Waiting for system to cool 1611-Fan failure 2 short Required fan not installed or Check fans. detected spinning. 1611-I/O Fan (Fan X) 2 short I/O fan has failed. Replace the failed fan. failure detected continued 3-12 Compaq ProLiant DL380 Maintenance and Service Guide Table 3-2 POST Error Messages continued Error Code Audible Beeps Probable Source of Problem Recommended Action 1611-CPU Fan 2 short CPU fan has failed. Replace the failed fan. (Fan X) failure detected 1612-Primary power 2 short Primary power supply has failed. Replace power supply as soon supply failure as possible. 1613-Low System None Real time clock system battery is Run Diagnostics. Replace failed Battery running low on power. assembly as indicated. 1615-Power Supply None A power supply has failed. Replace or check specified Failure, Power power supply. Supply Unplugged, or Power Supply Fan Failure in Bay X 1617-Fan controller 2 short Fan controller failure Check and replace failed not responding controller assembly. 1617-I/O Fan 2 short I/O fan controller failure Check and replace failed controller not controller assembly. responding 1617-CPU Fan 2 short CPU fan controller failure Check and replace failed controller not controller assembly. responding 1618-PCI slots None PCI hot plug enabler is missing or Check and replace missing or powered down. failed. failed assembly. Check PCI hot plug enabler connectors. 1620-Locked SCSI None SCSI bus failure Run Diagnostics. Replace failed Bus Detected. Verify assembly as indicated. SCSI bus cabling. System halted. 1621-Current SCSI None Improper SCSI bus cabling Check documentation for proper bus cable SCSI bus cabling. configuration is not recommended 1622-Internal SCSI None The system has detected that the Install the array enabler board. Jumper Board Not array enabler board is not Installed installed. 1703-SCSI cable None Incorrect cabling Ensure that the integrated SCSI error detected. controller has SCSI termination Internal SCSI cable attached. not attached to system board connector. System halted. continued Diagnostics and Troubleshooting 3-13 Table 3-2 POST Error Messages continued Error Code Audible Beeps Probable Source of Problem Recommended Action 1720-Slot x Drive None Indicated drive has reported a If drive is part of a Array SMART Drive SMART predictive-failure nonfault-tolerant configuration, Detects Imminent condition and may fail at some back up all data before Failure SCSI: Port y: time in the future. replacing drive and restore all SCSI ID x data afterward. If drive is part of a fault-tolerant configuration do not replace drive unless all other drives in array are online. Press F1 to resume. 1721-Slot x Drive None Monitor and performance Replace the drive when it is Array-Drive threshold exceeded condition. reasonable. The drive has not parameter tracking failed, but Compaq predicts imminent recommends you replace the failure. The following drive. devices should be replaced when conditions permit. Do not replace the drive unless all other drives in the array are online. Back up data before replacing drive(s) if using RAID 0. * 1724-Slot x Drive None Logical drive configuration has Press F1 to resume. Array Physical been updated automatically Drive Position following physical drive position Change(s) Detected changes. Logical drive configuration has automatically been updated * 1726-Slot x Drive None Indicates array accelerator Press F1 to resume. Array Array configuration has been updated Accelerator Memory automatically due to replacement Size Change of array accelerator (or controller) Detected with one having different memory size. continued 3-14 Compaq ProLiant DL380 Maintenance and Service Guide Table 3-2 POST Error Messages continued Error Code Audible Beeps Probable Source of Problem Recommended Action * 1727-Slot x Drive None Controller has detected an Press F1 to resume. Array New Logical additional array of drives that Drive(s) Attachment was attached when the power Detected. If more was off. The logical drive than 32 logical configuration information has drives, this message been updated to add the new will be followed by: logical drives. The maximum Auto-configuration number of logical drives failed: Too many supported is 32. Additional logical drives. logical drives will not be added to the configuration. 1729-Disk None This message is normal consistency following the initial initialization in configuration of RAID 4 or progress RAID 4/5 RAID 5 logical drives. This POST performance may be message will go away and lower until Auto performance of the controller Reliability Monitoring will improve after the parity data has completed has been initialized by ARM (an automatic parity automatic process that runs in consistency the back ground on the initialization. controller.) 1730-Fixed Disk 0 None Hard drive error Run the System Configuration does not support Utility and correct. DMA Mode. 1731-Fixed Disk 1 None Hard drive error Run the System Configuration does not support Utility and correct. DMA Mode. 1740-Fixed Disk 0 None Hard drive error Run the System Configuration failed Set Block Utility and correct. Mode command 1741-Fixed Disk 1 None Hard drive error Run the System Configuration failed Set Block Utility and correct. Mode command 1750-Fixed Disk 0 None Hard drive error Run the System Configuration failed Identify Utility and correct. command 1751-Fixed Disk 1 None Hard drive error Run the System Configuration failed Identify Utility and correct. command 1760-Fixed Disk 0 None Hard drive error Run the System Configuration does not support Utility and correct. Block Mode 1761-Fixed Disk 1 None Hard drive error Run the System Configuration does not support Utility and correct. Block Mode continued Diagnostics and Troubleshooting 3-15 Table 3-2 POST Error Messages continued Error Code Audible Beeps Probable Source of Problem Recommended Action 1764-Slot x Drive Array - Capacity Expansion Process is temporarily disabled Reattach or replace array (followed by one of the following): accelerator, wait until the array accelerator batteries have Expansion will resume when Array Accelerator has been reattached. charged, or for Automatic Data Recovery to complete, as Expansion will resume when Array Accelerator has been replaced.
indicated. Expansion will resume when Array Accelerator RAM allocation is successful.
Expansion will resume when Array Accelerator battery reaches full charge.
Expansion will resume when automatic data recovery has been completed.
1767-Slot x Drive Array Option ROM is Not Programmed Correctly or may Conflict Remove or reconfigure with the Memory Address Range of an ISA Card. Check the Memory Address conflicting ISA cards, especially Configuration of installed ISA Card(s) or run Options ROMPaq Utility to attempt any cards that are not SMART-2/E Option ROM Reprogramming. recognized by the System Configuration Utility. Try reprogramming the ROM on the SMART-2/E Controller using the latest Options ROMPaq (version 2.29 or higher). 1768-Slot x Drive None SMART-2 Controller error No action required. Appears Array-Resuming whenever a controller reset or logical drive power cycle occurs while array expansion process. expansion is in progress. 1769-Slot x Drive None SMART-2 Controller error. Data Press F2 to accept the data loss Array - Drive(s) has been lost while expanding and re-enable the logical drives. disabled due to the array; therefore, the drives Restore data from backup. failure during have been temporarily disabled. expand. Select F1 to continue with logical drives disabled. Select F2 to accept data loss and to re-enable logical drives. 1770-Slot x drive None Needs firmware update The indicated drives are running array critical drive firmware that is known to cause firmware problem intermittent problems. Please detected. Please use the Compaq Options upgrade firmware on ROMPaq utility to upgrade the following drive(s) firmware on all drives to the using Options latest revision. Press F1 or F2 to ROMPaq (available resume. from www.compaq.com); SCSI port (y) SCSI ID (x) (RESUME=F1 or F2 KEY) continued 3-16 Compaq ProLiant DL380 Maintenance and Service Guide Table 3-2 POST Error Messages continued Error Code Audible Beeps Probable Source of Problem Recommended Action 1771-Primary Disk None Internal and external hard drive Run the System Configuration Port Address controllers are both assigned to Utility and correct. Assignment Conflict the primary address. 1771-Primary Disk None Internal and external hard drive Run the System Configuration Port Address controllers are both assigned to Utility and correct. Assignment Conflict the primary address. 1772-Secondary None Address Assignment Conflict. Run the System Configuration Disk Port Address Internal and external hard drive Utility and correct. Assignment Conflict controllers are both assigned to the secondary address. 1773-Primary Fixed None Fixed disk drive error Run the System Configuration Disk Port Assignment Utility and correct. Conflict 1774-Slot x Drive None SMART-2 Controller error Data found in array accelerator Array - Obsolete data is older than data found on found in Array drives. Press F1 to discard the Accelerator. older data in the array Select F1 to discard accelerator and retain the contents of Array newer data on the drives. Accelerator. Select F2 to write contents of Array Accelerator to drives. 1775-Slot x Drive None Storage system problem Turn off power to system. Array - ProLiant Check external ProLiant power Storage System Not switch external drives must all Responding SCSI be powered up before or at the Port (y): Check same time as the main system. storage system Check cables. If retry does not power switch and help, try replacing the cable, cables. Turn the ProLiant firmware, ProLiant system power off backplane, or the Smart Array while checking the Controller. ProLiant power and Press F1 to resume. cable connections, then turn the system power back on to retry. 1776-Slot x Drive None External and internal SCSI drives The internal and external Array- SCSI Bus are both configured Port 1. connectors of the specified SCSI Termination port(s) are both attached to Error-internal and drives. The SCSI bus is not external drive cannot properly terminated when both be attached to internal and external drives are the same SCSI port. attached concurrently to the SCSI port (y). Check SCSI bus. The indicated SCSI cables. bus is disabled until this problem is resolved. Turn off the server power and check the cabling to the specified SCSI port. Press F1 to resume. continued Diagnostics and Troubleshooting 3-17 Table 3-2 POST Error Messages continued Error Code Audible Beeps Probable Source of Problem Recommended Action 1777-Slot x Drive None Cooling fan failure, internal Check cooling fan operation by Array ProLiant drive temperature alert or open side placing hand over fan. Check storage enclosure panel internal plenum cooling fan in problem detected tower servers or storage (followed by one or systems. If fan is not operating, more of the check for obstructions and following ) check all internal connectors. Replace unit side panel if SCSI Port (y) Colling removed. fan malfunction detected If the ProLiant Storage System power LED is amber instead of SCSI port (y) green this indicates a redundant Overheated condition power supply failure. detected Check SCSI cables. If the SCSI port (y) Side message indicates that the SCSI panel must be closed cables should be checked, to prevent please verify the cabling with overheating the diagrams in the Integrated Smart Array Controller SCSI port (y) Installation Guide. If the routing Redundant power is correct, replace the cables on supply malfunction the specified port until the POST detected. message is eliminated. SCSI port (y) Wide Press F1 to resume. SCSI transfer failed SCSI port (y) Interrupt signal inoperative 1778-Drive Array None This message appears whenever No action necessary. resuming Automatic a controller reset or power cycle Data Recovery occurs while Automatic Data process Recovery is in progress. 1779-Drive Array None Intermittent drive failure and/or If this message appears and Controller detects possible loss of data. drive x has not been replaced, replacement drives this indicates an intermittent drive failure. This message also Port (y) SCSI ID (x); appears once immediately Restore data from following drive replacement backup if whenever data must be restored replacement drive x from backup. has been installed. 1780-Disk 0 Failure None Hard drive/format error Run Diagnostics. Replace failed assembly as indicated. continued 3-18 Compaq ProLiant DL380 Maintenance and Service Guide Table 3-2 POST Error Messages continued Error Code Audible Beeps Probable Source of Problem Recommended Action 1781-Disk 1 Failure None Hard drive/format error Run Diagnostics. Replace failed assembly as indicated. 1782-Disk Controller None Hard disk drive circuitry error Run Diagnostics. Replace failed Failure assembly as indicated. 1783-Slot x Drive None ROM installation problem or array Check to see if: Array Controller accelerator board problem. If this The array accelerator board
Failure message appears immediately is attached properly. following a ROM installation, the ROM is defective or not installed The array controller is
properly. firmly inserted in its slot. If error recurs, upgrade the System ROMs. Otherwise, replace the Smart Array Controller. 1784-Drive Array None Defective drive and/or cables Check for loose cables. Replace Drive Failure The defective drive X and/or following SCSI cable(s). drive(s) should be replaced; SCSI port (y) SCSI ID (x) 1785-Drive Array not None Configuration error See actions below. Configured (followed Run the Compaq Array by one of the Configuration Utility. following) Turn off the system and check Run Compaq Array the SCSI cable connections to Configuration Utility make sure the drives are attached properly. No drives detected. Run Array Diagnostic Utility if previous positions are unknown. Drive positions Then turn system power Off and appear to have move drives to their original changed. positions. Drive positions To avoid data loss turn system appear to have power Off and reattach drives to changed. the original controller firmware to the version on the original Configuration controller using Option ROMPaq. information indicates Select F1 to resume. drive positions beyond the capability of this controller. This may be due to drive movement from a controller that supports more drives than the current controller. continued Diagnostics and Troubleshooting 3-19 Table 3-2 POST Error Messages continued Error Code Audible Beeps Probable Source of Problem Recommended Action 1786-Drive Array None Interim Data Recovery mode. Press F1 to start the Automatic Recovery Needed Data has not been recovered yet. Data Recovery to begin. Data will automatically be restored to The following drive(s) drive X now that the drive has need Automatic Data been replaced or now seems to Recovery: SCSI be working. port 1, SCSI ID O Or Select F1 to continue automatic data Press F2 and the system will recovery to drive. continue to operate in the Select F2 to continue Interim Data Recovery mode. without starting The previously aborted version automatic data of the 1786 POST message will recovery data to appear if the previous rebuild drive. attempt was aborted for any Or reason. Run Drive Array Advanced Diagnostics (DAAD) Slot 1 Drive Array for more information. If the Recovery needed. replacement drive was failed, Automatic data try using another replacement recovery previously drive. If rebuild was aborted due aborted. The to a read error from another following SCSI physical drive in the array, back drive(s) need up all readable data on the automatic data array. Run Diagnostics Surface recovery; SCSI Analysis to restore your data. port 1; SCSI ID 0. Select F1 to retry Automatic Data Recovery to drive. Select F2 to continue without starting Automatic Data Recovery to drive. 1787-Slot x Drive None Hard drive X failed or cable is 1. Replace drive X as soon as Array Operating in loose or defective. Following a possible. Interim Recovery system restart, this message 2. Check loose cables. Mode. The following reminds you that drive X is SCSI drive(s) should defective and fault tolerance is 3. Replace defective cables. be replaced: SCSI being used. port (y): SCSI ID (x) continued 3-20 Compaq ProLiant DL380 Maintenance and Service Guide Table 3-2 POST Error Messages continued Error Code Audible Beeps Probable Source of Problem Recommended Action * 1788-Slot x drive None Drives are not installed in their Reinstall the drives correctly as array reports original positions, so the drives indicated. incorrect drive have been disabled. See note Press F1 to restart the computer replacement. The below. with the drive array disabled. following SCSI drive(s) should have -Or- been replaced: SCSI Press F2 to use the drives as port (y), SCSI ID (x). configured and lose all the data The following SCSI on them. drive(s) were incorrectly replaced; SCSI port (y), SCSI ID (z). Select F1 to continue-drive array will remain disabled. Select F2 to reset configuration-all data will be lost. 1788-Slot x drive None Drives are not installed in their Reinstall the drives correctly as array reports original positions, so the drives indicated. incorrect drive have been disabled. See note Press F1 to restart the computer replacement. The below. with the drive array disabled. following SCSI drive(s) should have -Or- been replaced: SCSI Press F2 to use the drives as port (y), SCSI ID (x). configured and lose all the data The following SCSI on them. drive(s) were incorrectly replaced; SCSI port (y), SCSI ID (z). Select F1 to continue-drive array will remain disabled. Select F2 to reset configuration-all data will be lost. * The 1788 error message might display inadvertently due to a bad power cable connection to the drive or by noise on the data cable. If this message was due to a bad power cable connection, but not because of an incorrect drive replacement, repair the connection and press F2. -Or- If this message was not due to a bad power cable connection, and no drive replacement took place, this could indicate noise on the data cable. Check cable for proper routing. -Or- If this message is due to a defective SCSI cable, replace the cable. continued Diagnostics and Troubleshooting 3-21 Table 3-2 POST Error Messages continued Error Code Audible Beeps Probable Source of Problem Recommended Action 1789-Slot x Drive None Cable or hard drive failure 1. Check the cable array SCSI physical connections. drive(s) Not 2. Replace the cables. Responding. Check the cables or replace 3. Replace the drive. If you the following drives: do not want to replace the SCSI port (x), SCSI drive now, press F2. ID (x). Select F1 to continue - drive array will remain disabled. Select F2 to fail drive(s) that are not responding -Interim Recovery Mode will be enabled if configured for fault tolerance. 1790-Disk 0 None Hard drive error or wrong drive Run the System Configuration Configuration Error type Utility and Diagnostics and correct. 1791-Disk 1 Error None Hard drive error or wrong drive Run the System Configuration type Utility and Diagnostics and correct. 1792-Drive Array None This indicates that while the No action necessary; no data Reports Valid Data system was in use, power was has been lost. Perform orderly Found in Array interrupted while data was in the system shutdowns to avoid data Accelerator. array accelerator memory. Power remaining in the array was then restored within 8 to accelerator. Data will 10 days, and the data in the automatically be array accelerator was flushed to written to drive array. the drive array. 1793-Drive Array - None This indicates that while the Perform orderly system Array Accelerator system was in use, power was shutdowns to avoid data Battery Depleted - interrupted while data was in the remaining in the array Data Lost array accelerator memory. Array accelerator. accelerator batteries failed. (Error message 1794 Power was not restored within also displays.) 8 to 10 days. Data in array accelerator has been lost. 1794-Drive Array - None This is a warning that the battery Replace the array accelerator Array Accelerator charge is below 75%. board if batteries do not Battery Charge Low. Posted-writes are disabled. recharge within 36 power-on Array Accelerator is hours. temporarily disabled. Array Accelerator will be re-enabled when battery reaches full charge. continued 3-22 Compaq ProLiant DL380 Maintenance and Service Guide Table 3-2 POST Error Messages continued Error Code Audible Beeps Probable Source of Problem Recommended Action 1795-Drive Array - None This indicates that while the Match the array accelerator to Array Accelerator system was in use, power was the correct drive array, or run Configuration Error. interrupted while data was in the the System Configuration Utility array accelerator memory. to clear the data in the array Data does not accelerator. correspond to this The data stored in the array drive array. Array accelerator does not correspond Accelerator is to this drive array. temporarily disabled. 1796-Drive Array - None Array accelerator is defective or 1. Check that the array Array Accelerator Not has been removed. accelerator is properly Responding. seated. Array Accelerator is 2. Run the System temporarily disabled. Configuration Utility to reconfigure the Compaq IDA-2 without the array accelerator. 1797-Drive Array - None Hard parity error while reading Enable array accelerator. Array Accelerator data from posted-writes Read Error Occurred. memory. Data in Array Accelerator has been lost. Array Accelerator is disabled. 1798-Drive Array - None Hard parity error while writing Enable array accelerator. Array Accelerator data to posted-writes memory. Write Error Occurred. Array Accelerator is disabled. 1799-Drive Array - None Volume failed due to loss of data Press F1 to continue with Drive(s) Disabled due in posted-writes memory. logical drives disabled or F2 to to Array Accelerator accept data loss and re-enable Data Loss. Select F1 logical drive. to continue with logical drives disabled. Select F2 to accept data loss and to re-enable logical drives. Beeps only: 2 Long 2 long No valid memory is present in Replace failed memory with the system. valid memory. Beeps only: 2 Long + 2 long, 2 short Power is cycled. Temperature too Check fans. 2 Short hot. Processor fan not installed or spinning. (Run System None A configuration error occurred Press F10 to run System Configuration Utility - during POST. Configuration Utility. F10 key) (RESUME - F1 key) None As indicated to continue Press F1. Diagnostics and Troubleshooting 3-23 Diagnostics Software Test Error Codes Tables include all test error codes generated by Compaq products. Each code has a corresponding description and recommended action(s). Each system generates only those codes that apply to its configuration and options. When you select Diagnostics and Utilities from the System Configuration Utility main menu, the utility prompts you to test, inspect, upgrade, and diagnose the server. Diagnostics and Utilities are located on the Compaq system partition on the hard drive and must be accessed when a system configuration error is detected during the Power-On Self-Test (POST). Compaq Diagnostics software is also available on the Compaq SmartStart and Support Software CD. You can create a Diagnostics diskette from the SmartStart and Support Software CD and run Diagnostics from diskette. See procedure in the "Running Compaq Utilities" section earlier in this chapter. The following options are available from the Diagnostics and Utilities menu: Test Computer
Inspect Computer
Upgrade Firmware
Remote Utilities
Diagnose Drive Array
Diagnostic error codes are generated when the Diagnostics software recognizes a problem. These error codes help identify possible defective subassemblies. Steps for Diagnostics In each case, the Recommended Action column lists the steps necessary to correct the problem. After completing each step, run the Diagnostics utility to verify that the error condition has been corrected. If the error code reappears: 1. Perform the next step listed in the table. 2. Run the Diagnostics program again. 3. Follow this procedure until the Diagnostics program no longer detects an error condition. 3-24 Compaq ProLiant DL380 Maintenance and Service Guide 100 199, Primary Processor Test Error Codes The 100 series of diagnostic error codes identifies failures with processor and system board functions. Table 3-3 Primary Processor Test Error Codes Error Code Description Recommended Action 101-xx CPU test failed. Replace the processor board and retest. 103-xx DMA page registers test failed. Replace the processor board and retest. 104-xx Interrupt controller master test failed. 105-xx Port 61 error. 106-xx Keyboard controller self-test failed. 107-xx CMOS RAM test failed. 1. Replace the battery/clock module and retest. 2. Replace the system board and retest. 108-xx CMOS interrupt test failed. 109-xx CMOS clock load data test failed. Replace the processor board and retest. 110-xx Programmable timer load data test failed. 111-xx Refresh detect test failed. 112-xx Speed test slow mode out of range 113-xx Protected mode test failed. 114-xx Speaker test failed. 1. Verify the speaker connection and retest. 2. Replace the speaker and retest. 3. Replace the system board and retest. 116-xx Cache test failed. Replace the system board and retest. 1. Check the system configuration and retest. 122-xx Multiprocessor dispatch test failed. 2. Replace the processor board and retest. 123-xx Interprocessor communication test
| 122759-001 136363-005 143920-001 144086-001 144087-001 157824-001 157825-001 158855-001 159124-001 159125-001 159127-001 159128-001 159129-001 159137-001 159203-001 159225-001 159226-001 159227-001 159304-001 159542-001 163327-001 163902-001 166108-001 166109-001 173907-001 179161-001 179322-001 187781-001 187782-001 196628-001 212943-001 216394-001 216472-001 218257-001 221536-001 323332-001 327310-001 327313-001 327319-001 327322-001 327322-002 327919-001 333112-001 338482-001 340855-001 387090-001 400546-001 401859-001 |