Product Details

ProLiant DL320 Setup and Installation Guide
First Edition (September 2000)
Part Number 203836-001
Compaq Computer Corporation
Compaq Confidential Need to Know Required
Writer: GSaldivar Project: Compaq ProLiant DL320 Setup and Installation Guide Comments:
Part Number: 203836-001 File Name: a-frnt.doc Last Saved On: 8/23/00 4:50 PM
Notice
2000 Compaq Computer Corporation.
Compaq, ProLiant, Fastart, Compaq Insight Manager, ProLiant, ROMPaq, QVision, SmartStart,
NetFlex, QuickFind, PaqFax, ProSignia, registered United States Patent and Trademark Office.
Netelligent, SoftPaq, QuickBlank, QuickLock are trademarks and/or service marks of Compaq
Computer Corporation.
Microsoft, MS-DOS, Windows, and Windows NT are registered trademarks of Microsoft Corporation.
Pentium and Intel are registered trademarks of Intel Corporation.
All other product names mentioned herein may be trademarks or registered trademarks of their
respective companies.
Compaq shall not be liable for technical or editorial errors or omissions contained herein. The
information in this document is subject to change without notice.
The information in this publication is provided "AS IS" WITHOUT WARRANTY OF
ANY KIND. THE ENTIRE RISK ARISING OUT OF THE USE OF THIS
INFORMATION REMAINS WITH RECIPIENT. IN NO EVENT SHALL
COMPAQ BE LIABLE FOR ANY DIRECT, CONSEQUENTIAL, INCIDENTAL,
SPECIAL, PUNITIVE OR OTHER DAMAGES WHATSOEVER (INCLUDING
WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS PROFITS,
BUSINESS INTERRUPTION OR LOSS OF BUSINESS INFORMATION), EVEN
IF COMPAQ HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH
DAMAGES. THE FOREGOING SHALL APPLY REGARDLESS OF THE
NEGLIGENCE OR OTHER FAULT OF EITHER PARTY AND REGARDLESS
OF WHETHER SUCH LIABILITY SOUNDS IN CONTRACT, NEGLIGENCE,
TORT, OR ANY OTHER THEORY OF LEGAL LIABILITY, AND
NOTWITHSTANDING ANY FAILURE OF ESSENTIAL PURPOSE OF ANY
LIMITED REMEDY.
The limited warranties for Compaq products are exclusively set forth in the documentation
accompanying such products. Nothing herein should be construed as constituting a further or additional
warranty.
Compaq ProLiant DL320 Setup and Installation Guide
First Edition (September 2000)
Part Number 203836-001
Compaq Confidential Need to Know Required
Writer: GSaldivar Project: Compaq ProLiant DL320 Setup and Installation Guide Comments:
Part Number: 203836-001 File Name: a-frnt.doc Last Saved On: 8/23/00 4:50 PM
Contents
About This Guide
Text Conventions.........................................................................................................x
Symbols in Text..........................................................................................................xi
Symbols on Equipment...............................................................................................xi
Important Safety Information ....................................................................................xii
Getting Help ..............................................................................................................xii
Compaq Technical Support ................................................................................xii
Compaq Website............................................................................................... xiii
Compaq Authorized Reseller............................................................................ xiii
Chapter 1
Server Features
ProLiant DL320 Server............................................................................................ 1-1
Industry Support ...................................................................................................... 1-3
Standard Features..................................................................................................... 1-3
Processors ......................................................................................................... 1-3
System Memory................................................................................................ 1-3
Expansion Slot.................................................................................................. 1-4
Integrated Network Interface Controllers ......................................................... 1-4
Internal Storage Devices................................................................................... 1-5
Standard Interfaces ........................................................................................... 1-6
Video ................................................................................................................ 1-6
ROM ................................................................................................................. 1-6
Power Supply.................................................................................................... 1-7
Optional Rack Deployment Solutions .............................................................. 1-7
Desktop/Stackable Chassis Option ................................................................. 1-10
Compaq Remote Insight Lights-Out Edition (Optional)................................. 1-10
Warranties....................................................................................................... 1-10
Compaq Confidential Need to Know Required
Writer: GSaldivar Project: Compaq ProLiant DL320 Setup and Installation Guide Comments:
Part Number: 203836-001 File Name: a-frnt.doc Last Saved On: 8/23/00 4:50 PM
iv Compaq ProLiant DL320 Setup and Installation Guide
Server Features
continued
Server Configuration and Management ................................................................. 1-11
ROM-Based Setup Utility (RBSU)................................................................. 1-11
Compaq SmartStart......................................................................................... 1-11
Compaq Insight Manager................................................................................ 1-12
Automatic Server Recovery (ASR)................................................................. 1-12
Unit Identification Switches (Front and Rear) ................................................ 1-12
LED Indicators................................................................................................ 1-13
Compaq Remote Insight Lights-Out Edition (Optional)................................. 1-13
Diagnostic Features................................................................................................ 1-14
Security Features.................................................................................................... 1-14
Chapter 2
Planning the Server Installation
The Optimum Environment ..................................................................................... 2-2
Space Requirements.......................................................................................... 2-2
Power Requirements ......................................................................................... 2-2
Grounding Requirements .................................................................................. 2-3
Temperature Requirements............................................................................... 2-3
Airflow Requirements....................................................................................... 2-4
Additional Resource Information on Rack Installations .......................................... 2-5
Rack Warnings and Precautions............................................................................... 2-6
Server Warnings and Precautions ............................................................................ 2-7
Unpacking the ProLiant DL320 Server.................................................................... 2-8
Installing Expansion Boards and Other Major Hardware Options........................... 2-9
Chapter 3
Installing Hardware Options
Hardware Option Procedures ................................................................................... 3-2
Other Options........................................................................................................... 3-3
Preparing the Server................................................................................................. 3-3
Powering Down the Server ............................................................................... 3-3
Removing the Access Panel.............................................................................. 3-5
Removing the Shipping/Ejector Key ................................................................ 3-7
Removing the PCI Riser Board Assembly........................................................ 3-8
Removing the Center Wall................................................................................ 3-9
Identifying System Board Components .......................................................... 3-11
Installing the Center Wall ............................................................................... 3-13
Installing the Access Panel ............................................................................. 3-14
Installing Additional Memory................................................................................ 3-15
Compaq Confidential Need to Know Required
Writer: GSaldivar Project: Compaq ProLiant DL320 Setup and Installation Guide Comments:
Part Number: 203836-001 File Name: a-frnt.doc Last Saved On: 8/23/00 4:50 PM
Contents v
Installing Hardware Options
continued
Installing an Expansion Board............................................................................... 3-18
Identifying the Expansion Slot ....................................................................... 3-18
Removing the Expansion Slot Cover.............................................................. 3-19
Installing the Expansion Board....................................................................... 3-20
Installing the Compaq Remote Insight Lights-Out Edition (Optional).................. 3-23
Installing a CD-ROM/Diskette Drive Assembly (Optional).................................. 3-28
Removing a CD-ROM/Diskette Drive Assembly (Optional) ................................ 3-30
Guidelines for Installing Hard Drives.................................................................... 3-31
Guidelines for ATA Hard Drives.................................................................... 3-32
Guidelines for SCSI Hard Drives ................................................................... 3-32
Hard Drive Identification Numbers ................................................................ 3-33
Installing External Storage Devices................................................................ 3-34
Installing ATA Hard Drives .................................................................................. 3-34
Installing SCSI Hard Drives .................................................................................. 3-38
Installing a Compaq Smart Array Controller (SCSI Drives Internal) .................... 3-42
Installing a Compaq Smart Array Controller in a System with ATA Drives......... 3-47
Chapter 4
Installing the Server
Server Installation Overview ................................................................................... 4-1
Server Installation Procedures ................................................................................. 4-3
Measuring with the Template ........................................................................... 4-3
Attaching the Fixed Rack Rails to the Rack ..................................................... 4-6
Attaching the Fixed Cable Tray........................................................................ 4-8
Installing the Cable Support Bracket on the Server.......................................... 4-9
Inserting the Server into the Rack .................................................................. 4-10
Connecting the Power Cord and Peripheral Devices ............................................. 4-12
Securing the Cables in the Fixed Cable Tray......................................................... 4-14
Powering Up the Server......................................................................................... 4-15
Installation Sequence ............................................................................................. 4-17
Operating System Purchased Separately ........................................................ 4-17
Preconfigured Operating System .................................................................... 4-18
Registering Your Server ........................................................................................ 4-19
Routine Maintenance ............................................................................................. 4-19
Removing the Server from the Rack...................................................................... 4-20
Optional Installation Service ................................................................................. 4-24
Compaq Confidential Need to Know Required
Writer: GSaldivar Project: Compaq ProLiant DL320 Setup and Installation Guide Comments:
Part Number: 203836-001 File Name: a-frnt.doc Last Saved On: 8/23/00 4:50 PM
vi Compaq ProLiant DL320 Setup and Installation Guide
Chapter 5
Cabling Guidelines
Internal Cabling ....................................................................................................... 5-1
Internal Cabling for Storage Devices................................................................ 5-2
Internal Cabling for ProLiant DL320 Server Options....................................... 5-6
External Cabling ...................................................................................................... 5-6
Connecting the Power Cord and Peripheral Devices ........................................ 5-6
Routing the Power Cord and Peripheral Device Cables ................................... 5-7
External Mass Storage Cabling......................................................................... 5-7
ProLiant DL320 Maximum External Storage Cabling ..................................... 5-8
Chapter 6
Server Configuration and Utilities
ROM-Based Setup Utility (RBSU) .......................................................................... 6-2
Navigating the ROM-Based Setup Utility ........................................................ 6-2
Using the ROM-Based Setup Utility ................................................................ 6-3
ROMPaq .................................................................................................................. 6-6
SmartStart and Support Software CD ...................................................................... 6-7
Compaq Insight Manager......................................................................................... 6-8
SmartStart Diskette Builder ..................................................................................... 6-9
Compaq Survey Utility ............................................................................................ 6-9
Installing Survey ............................................................................................. 6-10
Running Survey .............................................................................................. 6-10
Compaq Diagnostic Utility .................................................................................... 6-10
Automatic Server Recovery (ASR)........................................................................ 6-11
Reapplying the System ROMPaq........................................................................... 6-11
Installing the Operating System ............................................................................. 6-11
Processor Operating Support .......................................................................... 6-11
Loading Compaq Device Drivers ................................................................... 6-12
Microsoft Windows NT Device Drivers from Compaq .................................. 6-12
Linux Device Drivers from Compaq .............................................................. 6-14
Controller Driver Naming Conventions................................................................. 6-14
Compaq Diagnostic Utility .................................................................................... 6-14
Chapter 7
Integrated Management Log
Viewing the Log ...................................................................................................... 7-1
Compaq Insight Manager.................................................................................. 7-2
Compaq Survey Utility ..................................................................................... 7-3
List of Events ........................................................................................................... 7-3
Compaq Confidential Need to Know Required
Writer: GSaldivar Project: Compaq ProLiant DL320 Setup and Installation Guide Comments:
Part Number: 203836-001 File Name: a-frnt.doc Last Saved On: 8/23/00 4:50 PM
Contents vii
Appendix A
Regulatory Compliance Notices
Regulatory Compliance Identification Numbers .....................................................A-1
Federal Communications Commission Notice ........................................................A-1
Class A Equipment ...........................................................................................A-2
Class B Equipment ...........................................................................................A-2
Declaration of Conformity for Products Marked with the FCC Logo
United States Only............................................................................................A-3
Modifications ....................................................................................................A-3
Cables ...............................................................................................................A-3
Canadian Notice (Avis Canadien) ...........................................................................A-4
Class A Equipment ...........................................................................................A-4
Class B Equipment ...........................................................................................A-4
European Union Notice ...........................................................................................A-4
Japanese Notice .......................................................................................................A-5
Taiwanese Notice.....................................................................................................A-5
Laser Devices...........................................................................................................A-5
Laser Safety Warnings......................................................................................A-6
Compliance with CDRH Regulations...............................................................A-6
Compliance with International Regulations......................................................A-6
Laser Product Label..........................................................................................A-6
Laser Information .............................................................................................A-7
Battery Replacement................................................................................................A-7
Power Cords ............................................................................................................A-8
Mouse Compliance Statement .................................................................................A-8
Appendix B
Electrostatic Discharge
Preventing Electrostatic Damage.............................................................................B-1
Grounding Methods ................................................................................................. B-2
Appendix C
Server Error Messages
POST Error Messages..............................................................................................C-1
ADU Error Messages.............................................................................................C-10
Compaq Confidential Need to Know Required
Writer: GSaldivar Project: Compaq ProLiant DL320 Setup and Installation Guide Comments:
Part Number: 203836-001 File Name: a-frnt.doc Last Saved On: 8/23/00 4:50 PM
viii Compaq ProLiant DL320 Setup and Installation Guide
Appendix D
Status Indicators and Switches
Status Indicators...................................................................................................... D-1
Front Panel LED Indicators ............................................................................. D-1
Rear Panel LED Indicators .............................................................................. D-3
Internal LED Indicators ................................................................................... D-4
Switches and Jumpers ............................................................................................. D-4
System Switch (SW2) ...................................................................................... D-6
System Configuration Switch (SW3)............................................................... D-7
Clearing and Resetting System Password Settings .......................................... D-8
Clearing and Resetting System Configuration Settings ................................... D-9
Enabling ROMPaq Disaster Recovery Mode .................................................. D-9
Setting the NIC Operating Mode ................................................................... D-10
Setting Hard Drive Jumpers........................................................................... D-10
Appendix E
Troubleshooting
When the Server Does Not Start .............................................................................. E-2
Diagnosis Steps........................................................................................................E-3
Server Operation Problems ...................................................................................... E-8
Appendix F
Server Specifications and Connector Interfaces
Compaq ProLiant DL320 Specifications ................................................................. F-1
Compaq ProLiant DL320 Connectors...................................................................... F-3
Rear Panel Connectors...................................................................................... F-3
Relevant System Board Connectors.................................................................. F-4
Appendix G
System Battery
System Battery Replacement .................................................................................. G-1
Index
Compaq Confidential Need to Know Required
Writer: GSaldivar Project: Compaq ProLiant DL320 Setup and Installation Guide Comments:
Part Number: 203836-001 File Name: a-frnt.doc Last Saved On: 8/23/00 4:50 PM
About This Guide
This guide is designed to be used as step-by-step instructions for installation
and as a reference for operation, troubleshooting, and future upgrades. The
chapters are written in a logical sequence to expedite first-time installation. An
overview of the chapters follows.
The ProLiant DL320 server contains unique features and options, as well as
software to enhance configuration and operation. To appreciate the server's
capabilities, see Chapter 1, "Server Features."
Before beginning the server installation, you must choose an appropriate
location in which to install your ProLiant DL320 server and install your
internal options. See Chapter 2, "Planning the Server Installation," and
Chapter 3, "Installing Hardware Options."
Installing your ProLiant DL320 server into a Compaq rack with standard rack
management hardware requires the installation of the cable support bracket.
See Chapter 4, "Installing the Server."
In Chapter 5, "Cabling Guidelines," you can identify all of the standard
cabling configurations and learn about optional internal and external cabling
configurations for the ProLiant DL320.
Configuring your ProLiant DL320 server for the first time is made easier with
utilities on the Compaq SmartStart and Support Software CD. The SmartStart
utility can assist you by installing drivers for hardware and operating systems.
See Chapter 6, "Server Configuration and Utilities."
Compaq's standard management software includes the Integrated Management
Log (IML) that records diagnostic information. Review the capabilities and
functions of this software feature in Chapter 7, "Integrated Management Log."
Compaq Confidential Need to Know Required
Writer: GSaldivar Project: Compaq ProLiant DL320 Setup and Installation Guide Comments:
Part Number: 203836-001 File Name: a-frnt.doc Last Saved On: 8/23/00 4:50 PM
x Compaq ProLiant DL320 Setup and Installation Guide
To prevent hardware damage and loss of data, the ProLiant DL320 server is
designed to operate only when all components are functioning properly. The
server generates event messages and/or suspends operation if a component
becomes degraded from wear or becomes unseated from its connection.
Appendix E, "Troubleshooting," helps you determine the source of the error
and suggests steps to remedy the situation.
The appendices at the end of this guide provide supplementary and reference
information, such as regulatory notices, guidelines for preventing electrostatic
damage to components, server-specific error messages you may encounter
when operating this server, explanations of LED indicators and switches,
troubleshooting techniques for easily pinpointing any problems encountered
during operation, operating specfiications, and battery replacement for the
ProLiant DL320 server.
Text Conventions
This document uses the following conventions to distinguish elements of text:
Keys Keys appear in boldface. A plus sign (+) between
two keys indicates that they should be pressed
simultaneously.
USER INPUT User input appears in a different typeface and in
uppercase.
FILENAMES File names appear in uppercase italics.
Menu Options, These elements appear in initial capital letters.
Command Names,
Dialog Box Names
COMMANDS, These elements appear in uppercase.
DIRECTORY NAMES,
and DRIVE NAMES
Type When you are instructed to type information, type
the information without pressing Enter.
Enter When you are instructed to enter information, type
the information and then press Enter.
Compaq Confidential Need to Know Required
Writer: GSaldivar Project: Compaq ProLiant DL320 Setup and Installation Guide Comments:
Part Number: 203836-001 File Name: a-frnt.doc Last Saved On: 8/23/00 4:50 PM
About This Guide xi
Symbols in Text
These symbols may be found in the text of this guide. They have the following
meanings.
WARNING: Text set off in this manner indicates that failure to follow directions
in the warning could result in bodily harm or loss of life.
CAUTION: Text set off in this manner indicates that failure to follow directions
could result in damage to equipment or loss of information.
IMPORTANT: Text set off in this manner presents clarifying information or specific
instructions.
NOTE: Text set off in this manner presents commentary, sidelights, or interesting points
of information.
Symbols on Equipment
These symbols are located on equipment in areas where hazardous conditions
may exist.
This symbol in conjunction with any of the following symbols indicates the
presence of a potential hazard. The potential for injury exists if warnings
are not observed. Consult your documentation for specific details.
This symbol indicates the presence of hazardous energy circuits or
electric shock hazards. Refer all servicing to qualified personnel.
WARNING: To reduce the risk of injury from electric shock hazards, do
not open this enclosure. Refer all maintenance, upgrades, and
servicing to qualified personnel.
This symbol indicates the presence of electric shock hazards. The area
contains no user or field serviceable parts. Do not open for any reason.
WARNING: To reduce the risk of injury from electric shock hazards,
do not open this enclosure.
Compaq Confidential Need to Know Required
Writer: GSaldivar Project: Compaq ProLiant DL320 Setup and Installation Guide Comments:
Part Number: 203836-001 File Name: a-frnt.doc Last Saved On: 8/23/00 4:50 PM
xii Compaq ProLiant DL320 Setup and Installation Guide
This symbol on an RJ-45 receptacle indicates a Network Interface
Connection.
WARNING: To reduce the risk of electric shock, fire, or damage to the
equipment, do not plug telephone or telecommunications connectors
into this receptacle.
This symbol indicates the presence of a hot surface or hot component.
If this surface is contacted, the potential for injury exists.
WARNING: To reduce the risk of injury from a hot component, allow
the surface to cool before touching.
This symbol indicates that the component exceeds the
recommended weight for one individual to handle safely.
Weight kg WARNING: To reduce the risk of personal injury or damage to the
equipment, observe local occupational health and safety
Weight lb
requirements and guidelines for manual material handling.
Important Safety Information
Before installing this product, read the Important Safety Information document
provided.
Getting Help
If you have a problem and have exhausted the information in this guide, you
can get further information and help in the following locations.
Compaq Technical Support
In North America, call the Compaq Technical Phone Support Center at
1
1-800-OK-COMPAQ . This service is available 24 hours a day, 7 days a week.
1
For continuous quality improvement, calls may be recorded or monitored.
Compaq Confidential Need to Know Required
Writer: GSaldivar Project: Compaq ProLiant DL320 Setup and Installation Guide Comments:
Part Number: 203836-001 File Name: a-frnt.doc Last Saved On: 8/23/00 4:50 PM
About This Guide xiii
Outside North America, call the nearest Compaq Technical Support Phone
Center. Telephone numbers for worldwide Technical Support Centers are
listed on the Compaq website. Access the Compaq website by logging on to
the Internet:
http://www.compaq.com
Be sure to have the following information available before you call Compaq:
I Technical support registration number (if applicable)
I Product serial numbers
I Product model names and numbers
I Applicable error messages
I Add-on boards or hardware
I Third-party hardware or software
I Operating system type and revision level
I Detailed, specific questions
Compaq Website
The Compaq website has information on this product as well as the latest
drivers and Flash ROM images. You can access the Compaq website by
logging on to the Internet:
http://www.compaq.com
Compaq Authorized Reseller
For the name of your nearest Compaq Authorized Reseller:
I In the United States, call 1-800-345-1518.
I In Canada, call 1-800-263-5868.
I Elsewhere, see the Compaq website for locations and telephone
numbers.
Compaq Confidential Need to Know Required
Writer: GSaldivar Project: Compaq ProLiant DL320 Setup and Installation Guide Comments:
Part Number: 203836-001 File Name: a-frnt.doc Last Saved On: 8/23/00 4:50 PM
1
Chapter
Server Features
The Compaq ProLiant DL320 ultra-dense, one-way rack server delivers
performance and scalability in a flexible, easy to manage design. Optimized
for quick, high-volume deployment, the ProLiant DL320 server is an excellent
platform for front-end Internet services and data center environments.
ProLiant DL320 Server
The following features are standard on the ProLiant DL320 server, unless
otherwise noted:
I Intel Pentium III processor, with 256-KB L2 cache and 133-MHz
front-side system bus
I Single processor capability
I Support for up to 2GB of PC133-MHz ECC registered, SDRAM
DIMMs
I Two embedded Compaq NC3163 Fast Ethernet network interface
controllers (NICs) with 10/100 Wake on LAN (WOL) support
I Integrated ATI Rage XL Video Controller with 4-MB video memory
I Integrated Single Channel Wide Ultra2 SCSI Controller Module (SCSI
models only)
I Ultra ATA/100 Controller Module (ATA models only)
I Capacity for two 1-inch ATA or SCSI non-hot-plug hard drives
I One full-length 64-bit PCI slot operating at 33 MHz
Compaq Confidential Need to Know Required
Writer: Gilbert Saldivar Project: Compaq ProLiant DL320 Setup and Installation Guide Comments:
Part Number: 203836-001 File Name: b-ch1 Server Features.doc Last Saved On: 8/23/00 3:45 PM
1-2 Compaq ProLiant DL320 Setup and Installation Guide
I Front panel status LED indicators
I Two Universal Serial Bus (USB) ports
I Optional CD-ROM/diskette drive assembly
ProLiant DL320 servers also support tool-free in-rack accessibility to major
components.
Among its standard features, the ProLiant DL320 server has minimized
cabling, an integrated processor power module, and a unit identification switch
that simplifies the logistics of service procedures. The ProLiant DL320 server
also supports numerous optional features, including memory upgrades, a
CD-ROM/diskette drive assembly, full-graphic remote management
capability, and additional connectivity for enhanced array control of internal
and external storage devices via an optional PCI expansion board. In-rack
serviceability is possible with an optional rack management solution that
contains ball-bearing slide rails and a cable management system.
This combination of features, performance, form factor, and Compaq
manageability enables the ProLiant DL320 server to support Web and
application hosting and infrastructure applications while providing maximum
density in rack configurations.
Figure 1-1. Compaq ProLiant DL320 server
Compaq Confidential Need to Know Required
Writer: Gilbert Saldivar Project: Compaq ProLiant DL320 Setup and Installation Guide Comments:
Part Number: 203836-001 File Name: b-ch1 Server Features.doc Last Saved On: 8/23/00 3:45 PM
Server Features 1-3
Industry Support
Compaq delivers extensive testing and support for major server operating
systems. Because Compaq provides an industry standard bus for expansion,
you have access to thousands of high-performance PCI expansion boards, as
well as support for ATA or SCSI devices.
Standard Features
The features described in the following sections are standard on all Compaq
ProLiant DL320 servers, unless otherwise specified.
Processors
ProLiant DL320 servers support the following advanced processor features:
I Integrated Level 2 cache
I Integrated processor power module (PPM)
I Processor configurations and models for an Intel processor with
133-MHz front-side bus (FSB) operation
System Memory
ProLiant DL320 servers support the following memory features:
I 133-MHz registered SDRAM memory (Synchronous DRAM)
I Error checking and correcting (ECC) memory for detecting and
correcting single-bit memory errors
I System memory expandable to 2 GB (four DIMM sockets)
I Support for installing a single DIMM module at a time
Compaq Confidential Need to Know Required
Writer: Gilbert Saldivar Project: Compaq ProLiant DL320 Setup and Installation Guide Comments:
Part Number: 203836-001 File Name: b-ch1 Server Features.doc Last Saved On: 8/23/00 3:45 PM
1-4 Compaq ProLiant DL320 Setup and Installation Guide
Expansion Slot
ProLiant DL320 servers provide support for peripheral components. The
expansion slot on the PCI riser board assembly is a 64-bit PCI expansion slot
that provides data transfer at up to 267 MB/s.
The PCI bus provides peripheral transactions at a system clock speed
of 33 MHz.
Integrated Network Interface Controllers
The standard network interface controllers (NICs) provided with your
ProLiant DL320 server have the following features:
I Two embedded Compaq NC3163 Fast Ethernet NICs 10/100 WOL with
Unshielded Twisted Pair (UTP) support
I Preboot Execution Environment (PXE) support on NIC 1 for
downloading a complete operating system configuration from your
network
I Autosensing LAN capable of 10 or 100 Mbit/s
I Full-duplex Ethernet for two-way transmission
I Wake On LAN (WOL) support
I Two RJ-45 connectors for 10-BaseT or 100TX Ethernet
For more information about the integrated NICs, refer to the Documentation
CD shipped with your server.
Compaq Confidential Need to Know Required
Writer: Gilbert Saldivar Project: Compaq ProLiant DL320 Setup and Installation Guide Comments:
Part Number: 203836-001 File Name: b-ch1 Server Features.doc Last Saved On: 8/23/00 3:45 PM
Server Features 1-5
Internal Storage Devices
The ProLiant DL320 server can house up to four storage devices:
I Up to two 1-inch height Compaq ATA or SCSI non-hot-plug hard
drives
I A removable CD-ROM/diskette drive assembly including the

following:
G Low-profile 3.5-inch diskette drive
G Low-profile CD-ROM drive
2
1
Figure 1-2. ProLiant DL320 server drive positions (front view)
Compaq Confidential Need to Know Required
Writer: Gilbert Saldivar Project: Compaq ProLiant DL320 Setup and Installation Guide Comments:
Part Number: 203836-001 File Name: b-ch1 Server Features.doc Last Saved On: 8/23/00 3:45 PM
1-6 Compaq ProLiant DL320 Setup and Installation Guide
Standard Interfaces
The ProLiant DL320 server is equipped with the following standard interfaces:
I Serial (teal)
I Video (blue)
I Keyboard (purple)
I Mouse (green)
I Two embedded Compaq NC3163 Fast Ethernet NICs 10/100 WOL with
Unshielded Twisted Pair (UTP) support
I IDE/diskette interface for the CD-ROM/diskette drive assembly
I Interface cable connector for the Remote Insight Lights-Out Edition
option
I Two Universal Serial Bus (USB) connectors
Video
Standard video integration in ProLiant DL320 servers includes the following:
I Integrated video controller with maximum resolution of 1280 1024
noninterlaced resolution at 16.7 million colors
I Support for SVGA and VGA graphics resolution
I 4-MB video memory
ROM
Compaq ROM features include the following:
I Compaq ROMPaqTM Utility for BIOS firmware upgrade
I ROM-Based Setup Utility (RBSU) for system configuration
Compaq Confidential Need to Know Required
Writer: Gilbert Saldivar Project: Compaq ProLiant DL320 Setup and Installation Guide Comments:
Part Number: 203836-001 File Name: b-ch1 Server Features.doc Last Saved On: 8/23/00 3:45 PM
Server Features 1-7
Power Supply
The ProLiant DL320 server's standard power supply includes the following:
I 180-watt power supply
I Auxiliary power supply output for Compaq Remote Insight Lights-Out
Edition PCI board and WOL network interface controllers
Optional Rack Deployment Solutions
The ProLiant DL320 server ships standard with fixed rails and supports
several rack deployment options.
Sliding Rail and Cable Management System
Option
The sliding rail and cable management system option allows you to mount the
ProLiant DL320 server on ball-bearing rails that support in-rack serviceability.
The cable management system provides a clean, effective way to route server
cables.
The following figure shows the server extending from the rack on ball-bearing
slide rails.
1
1
2
Figure 1-3. Extending the server on sliding rails
Compaq Confidential Need to Know Required
Writer: Gilbert Saldivar Project: Compaq ProLiant DL320 Setup and Installation Guide Comments:
Part Number: 203836-001 File Name: b-ch1 Server Features.doc Last Saved On: 8/23/00 3:45 PM
1-8 Compaq ProLiant DL320 Setup and Installation Guide
The cable management system channels the server cables along the back of the
server to connection points on the rack.
Figure 1-4. Cables routed at the rear of the server (top view of rear of server)
Telco Rack Option
The Telco rack option contains a set of variable-depth rack brackets that
support installation of the ProLiant DL320 server into a Telco rack. These
brackets adjust to fit several types of Telco racks. The kit contains the
necessary mounting screws, brackets, and installation instructions.
Figure 1-5. Server mounted in Telco rack
Compaq Confidential Need to Know Required
Writer: Gilbert Saldivar Project: Compaq ProLiant DL320 Setup and Installation Guide Comments:
Part Number: 203836-001 File Name: b-ch1 Server Features.doc Last Saved On: 8/23/00 3:45 PM
Server Features 1-9
Third-Party Cabinet Rack Option
Compaq provides a third-party cabinet rack option that allows you to mount
the ProLiant DL320 server in a third-party rack. The variable-depth rack rails
support server installation in racks with depths of 28 to 33 inches (711 to
838 mm) with the cable management tray or depths of 22 to 33 inches (559 to
838 mm) without the cable management tray.
Figure 1-6. Installing the server into a third-party rack
The following figure shows the third-party cabinet rack option.
Figure 1-7. Cable tray for the third-party rack option (cables removed for
clarity)
Compaq Confidential Need to Know Required
Writer: Gilbert Saldivar Project: Compaq ProLiant DL320 Setup and Installation Guide Comments:
Part Number: 203836-001 File Name: b-ch1 Server Features.doc Last Saved On: 8/23/00 3:45 PM
1-10 Compaq ProLiant DL320 Setup and Installation Guide
Desktop/Stackable Chassis Option
The desktop/stackable chassis option consists of a slide-on sheet metal chassis
that converts the rack model ProLiant DL320 server for desktop use. When
installed in the desktop chassis, the server can be deployed for nonrack use.
Figure 1-8. Server mounted in the desktop/stackable chassis
Compaq Remote Insight Lights-Out Edition
(Optional)
The ProLiant DL320 server has standard features that support the Remote
Insight Lights-Out Edition option:
I Power supply support for Remote Insight Lights-Out Edition
I Interface cable connector on the system board
NOTE: The interface cable for the Remote Insight Lights-Out Edition ships with the
Remote Insight Lights-Out Edition option kit.
Warranties
The ProLiant DL320 server is equipped with several standard warranties. For
more information, refer to the Important Warranty Information card shipped
with your server.
Compaq Confidential Need to Know Required
Writer: Gilbert Saldivar Project: Compaq ProLiant DL320 Setup and Installation Guide Comments:
Part Number: 203836-001 File Name: b-ch1 Server Features.doc Last Saved On: 8/23/00 3:45 PM
Server Features 1-11
Server Configuration and Management
The ProLiant DL320 server offers an extensive set of features and optional
tools that support effective server management and configuration, including:
I ROM-Based Setup Utility (RBSU)
I Compaq SmartStartTM
I Compaq Insight ManagerTM
I Automatic Server Recovery (ASR)
I Unit Identification Switches
I LED Indicators
I Compaq Remote Insight Lights-Out Edition (Optional)
ROM-Based Setup Utility (RBSU)
The ROM-Based Setup Utility (RBSU) (or F9 setup) performs a wide range of
configuration activities, including the following:
I Viewing system information
I Selecting the operating system
I Configuring system devices and installed options
I Selecting the primary boot controller
I Managing storage options
Compaq SmartStart
SmartStart, located on the SmartStart and Support Software CD, is the
intelligent way to set up your Compaq server. SmartStart includes:
I ROMPaq Utility
I Driver updates
I Assisted operating system installations
For information concerning SmartStart, refer to the Server Setup and
Management pack included in the shipping box.
Compaq Confidential Need to Know Required
Writer: Gilbert Saldivar Project: Compaq ProLiant DL320 Setup and Installation Guide Comments:
Part Number: 203836-001 File Name: b-ch1 Server Features.doc Last Saved On: 8/23/00 3:45 PM
1-12 Compaq ProLiant DL320 Setup and Installation Guide
Compaq Insight Manager
Compaq Insight Manager, which is loaded from the Compaq Management CD,
is an easy-to-use software utility for collecting server information. Compaq
Insight Manager performs the following functions:
I Forwards server alerts and fault conditions
I Monitors fault conditions and server performance
I Controls server security and configuration
I Remotely controls the server
I Initiates rapid recovery services
Automatic Server Recovery (ASR)
Automatic Server Recovery (ASR) enables the server to boot automatically
from either the operating system or the Compaq Utilities. If a critical system
failure occurs, ASR automatically restarts the server and pages a designated
system administrator.
For additional information on the ASR feature, refer to the Documentation CD
that shipped with your server.
Unit Identification Switches (Front and Rear)
Each ProLiant DL320 server has two unit identification switches, one on the
front of the server and one on the back of the server. When activated from
either the front or the rear of the server, the unit identification switches
illuminate both the front and rear unit identification LEDs to provide a visual
reference for service personnel.
When moving between the front and rear of a rack filled with ProLiant DL320
servers, you can use the unit identification switches to quickly identify one or
more ProLiant DL320 servers that require service or maintenance.
Compaq Confidential Need to Know Required
Writer: Gilbert Saldivar Project: Compaq ProLiant DL320 Setup and Installation Guide Comments:
Part Number: 203836-001 File Name: b-ch1 Server Features.doc Last Saved On: 8/23/00 3:45 PM
Server Features 1-13
Figure 1-9 shows the locations of the following items:
I Front unit identification switch and front unit identification LED

I Rear unit identification LED switch
2
1 3
Figure 1-9. Locating the front (left) and rear (right) unit identification switches
and LED indicators
LED Indicators
The ProLiant DL320 server contains several sets of LEDs that indicate the
status of hardware components and settings. For a detailed explanation of LED
status and locations, see Appendix D, "Status Indicators and Switches."
NOTE: The unit identification LED indicators illuminate blue.
Compaq Remote Insight Lights-Out Edition
(Optional)
The Compaq Remote Insight Lights-Out Edition option is a PCI-based board
that provides remote server management, regardless of the state of the host
server operating system or the host CPU.
A built-in Intel i960 processor allows the Remote Insight Lights-Out Edition
module to work independently of the host server operating system.
Compaq Confidential Need to Know Required
Writer: Gilbert Saldivar Project: Compaq ProLiant DL320 Setup and Installation Guide Comments:
Part Number: 203836-001 File Name: b-ch1 Server Features.doc Last Saved On: 8/23/00 3:45 PM
1-14 Compaq ProLiant DL320 Setup and Installation Guide
This module provides remote access and video, sends alerts, and performs
other functions, even if the host server operating system is not responding.
For installation and features information, refer to the documentation that ships
with your Remote Insight Lights-Out Edition and see "Installing the Remote
Insight Lights-Out Edition (Optional)" in Chapter 3, "Installing Hardware
Options."
Diagnostic Features
The software and firmware diagnostic features available for your use include:
I Power-On Self-Test (POST)
I Diagnostics (DIAGS)
I ROMPaq utilities to upgrade flash BIOS
I Automatic Server Recovery (ASR)
Security Features
Security features include:
I Setup Password
I Power-up Password
I Diskette Drive Control
I Diskette Write Control
I Diskette Boot Override
I Serial Interface Control
I CD Boot Override
Most security features are established through the RBSU. For information
concerning server security features, refer to the SmartStart and Support
Software CD included in the shipping box.
Compaq Confidential Need to Know Required
Writer: Gilbert Saldivar Project: Compaq ProLiant DL320 Setup and Installation Guide Comments:
Part Number: 203836-001 File Name: b-ch1 Server Features.doc Last Saved On: 8/23/00 3:45 PM
2
Chapter
Planning the Server Installation
This chapter provides information and instructions for planning the installation
of your new Compaq ProLiant DL320 server.
Figure 2-1. ProLiant DL320 servers installed in the rack
You can choose the optional installation service from Compaq to install your
rack products. Refer to the "Optional Installation Service" at the end of
Chapter 4, "Installing the Server" for additional information.
If you intend to deploy and configure multiple ProLiant DL320 servers in a
single rack, consult the Compaq ProLiant DL320 Ultra-Dense Server
Deployment in Compaq Racks white paper on the Compaq website:
http://www.compaq.com/
Compaq Confidential Need to Know Required
Writer: Gilbert Saldivar Project: Compaq ProLiant DL320 Setup and Installation Guide Comments:
Part Number: 203836-001 File Name: c-ch2 Planning the Server Installation.doc Last Saved On: 8/23/00 3:47 PM
2-2 Compaq ProLiant DL320 Setup and Installation Guide
The Optimum Environment
When installing your Compaq ProLiant DL320 server in a rack, select a
location that meets the environmental standards described in the following
paragraphs.
Space Requirements
Consider the following spatial requirements when deciding where to install
your rack:
I Leave a minimum clearance of 25 inches in front of the rack to allow the
front door to open all the way and to allow for adequate airflow.
I Leave a minimum clearance of 30 inches in the back of the rack to allow
for servicing and adequate airflow.
Power Requirements
WARNING: To reduce the risk of personal injury, fire, or damage to the
equipment, do not overload the AC supply branch circuit that provides power to
the rack. Consult the electrical authority having jurisdiction over your facility's
wiring and installation requirements.
The installation of this equipment shall be in accordance with local/regional
electrical regulations governing the installation of information technology
equipment by licensed electricians. This equipment is designed to operate in
installations covered by NFPA 70-1999 (National Electric Code) and
NFPA-75, 1992 (code for Protection of Electronic Computer/Data Processing
Equipment). For electrical power ratings on options, refer to the product's
rating label or the user documentation supplied with that option.
When installing more than one server, you may need to use additional power
distribution devices to safely provide power to all devices.
I The power load must be balanced between available AC supply branch
circuits.
I The overall system AC current load must not exceed 80 percent of the
branch circuit AC current rating.
Compaq Confidential Need to Know Required
Writer: Gilbert Saldivar Project: Compaq ProLiant DL320 Setup and Installation Guide Comments:
Part Number: 203836-001 File Name: c-ch2 Planning the Server Installation.doc Last Saved On: 8/23/00 3:47 PM
Planning the Server Installation 2-3
Grounding Requirements
For proper operation and safety, the server must be properly grounded. In the
United States, you must install the equipment in accordance with
NFPA 70-1999 (National Electric Code) Article 250 as well as any local and
regional building codes. In Canada, the equipment must be installed in
accordance with Canadian Standards Association, CSA C22.1, Canadian
Electrical Code. In all other countries, the installation must follow any
regional or national electrical wiring codes, such as the International
Electrotechnical Commission (IEC) 364, parts 1 through 7. Furthermore, you
must ensure that all power distribution devices used in the installation--such
as branch wiring and receptacles--are listed or certified grounding-type
devices.
Because of the high ground leakage currents associated with multiple servers
connected to the same power source, Compaq recommends the use of a power
distribution unit (PDU) that is either permanently wired to the building's
branch circuit or includes a nondetachable cord that is wired to an industrial-
style plug. NEMA locking-style plugs or those complying with IEC 60309 are
considered suitable for this purpose. Compaq does not recommend using
common power outlet strips for this equipment.
Temperature Requirements
To ensure continued safe and reliable equipment operation, install or locate the
system in a well-ventilated, climate controlled environment.
The Compaq Maximum Recommended Ambient Operating Temperature
(TMRA) for most server products is 35C (95F). The temperature in the room
where the rack is located should not exceed 35C (95F).
Compaq Confidential Need to Know Required
Writer: Gilbert Saldivar Project: Compaq ProLiant DL320 Setup and Installation Guide Comments:
Part Number: 203836-001 File Name: c-ch2 Planning the Server Installation.doc Last Saved On: 8/23/00 3:47 PM
2-4 Compaq ProLiant DL320 Setup and Installation Guide
Airflow Requirements
CAUTION: When using a Compaq Series 7000 rack, you must install the high
air flow rack door insert to provide proper front-to-back airflow and cooling.
Compaq ProLiant DL320 servers draw cool air in through the front door and
exhaust warm air out the rear. Therefore, the front door of the rack must be
adequately ventilated to allow ambient room air to enter the cabinet, and the
rear door must be adequately ventilated to allow the warm air to escape from
the cabinet. Do not block the ventilation openings.
Blanking Panels
CAUTION: Always use blanking panels to fill empty vertical spaces in the rack.
This arrangement ensures proper airflow. Using a rack without blanking panels
results in improper cooling that can lead to thermal damage.
If any of the vertical space in the rack is not filled by components, the gaps
between the components will cause changes in airflow through the rack and
across the components. Cover these gaps with blanking panels to maintain
proper airflow.
CAUTION: Avoid thermal events that could cause damage to your system by
ensuring that there are at least 19.75 square inches (50.16 sq cm) of open
space in the front and back rack door for each ProLiant DL320 server. If this
amount of space is not available, remove the doors to allow proper ventilation.
Compaq Confidential Need to Know Required
Writer: Gilbert Saldivar Project: Compaq ProLiant DL320 Setup and Installation Guide Comments:
Part Number: 203836-001 File Name: c-ch2 Planning the Server Installation.doc Last Saved On: 8/23/00 3:47 PM
Planning the Server Installation 2-5
Additional Resource Information on Rack
Installations
The following resource information is available on rack designs and products.
The Rack Builder Pro Configuration Tool and Rack Products Documentation
information can be found on the Compaq website:
http://www.compaq.com
The entire Rack Resource CD Kit ships with all Compaq racks. A summary of
the content of each CD follows:
I Rack Builder Pro Configuration Tool
This information allows you to simulate potential Compaq rack
configurations based on your input. Rack Builder Pro provides the
following information:
G Graphical preview of properly configured racks
G Site planning data, including power requirements, cooling mandates,
and physical specifications
G Ordering information, including required components, part numbers,
and appropriate quantities
I Installing Rack Products video
This video provides a visual overview of operations required for
configuring a Compaq rack with rack-mountable components. It also
provides the following key configuration steps:
G Site planning
G Installing rack servers and rack options
G Cabling
G Coupling multiple racks together
I Rack Products Documentation CD
The resource information on this CD allows you to view, search, and
print documentation for Compaq racks and rack options. It also helps
you set up and optimize your new Compaq rack in a manner that best
fits your environment.
Compaq Confidential Need to Know Required
Writer: Gilbert Saldivar Project: Compaq ProLiant DL320 Setup and Installation Guide Comments:
Part Number: 203836-001 File Name: c-ch2 Planning the Server Installation.doc Last Saved On: 8/23/00 3:47 PM
2-6 Compaq ProLiant DL320 Setup and Installation Guide
Rack Warnings and Precautions
Before beginning these procedures, make sure you understand the following
warnings and cautions:
WARNING: To reduce the risk of personal injury or equipment damage, always
ensure that the rack is adequately stabilized before extending a component
outside the rack. A rack may become unstable if more than one component is
extended for any reason. Extend only one component at a time.
WARNING: To reduce the risk of personal injury or equipment damage, be sure
that:
I The leveling jacks are extended to the floor.
I The full weight of the rack rests on the leveling jacks.
I The stabilizers are attached to the rack for single-rack installation.
I The racks are coupled together in multiple-rack installations.
WARNING: When installing the server in a Telco rack, make certain that the
rack frame is adequately secured to the top and bottom of the building
structure.
WARNING: To reduce the risk of personal injury or equipment damage, at least
two people are needed to safely unload the rack from the pallet. An empty 42U
rack can weigh as much as 253 lb (115 kg), can stand more than 7 ft (2.1 m)
tall, and may become unstable when being moved on its casters.
Never stand in front of the rack when it is rolling down the ramp from the pallet;
always handle the rack from both sides.
Compaq Confidential Need to Know Required
Writer: Gilbert Saldivar Project: Compaq ProLiant DL320 Setup and Installation Guide Comments:
Part Number: 203836-001 File Name: c-ch2 Planning the Server Installation.doc Last Saved On: 8/23/00 3:47 PM
Planning the Server Installation 2-7
Server Warnings and Precautions
Before beginning these procedures, make sure you understand the following
warnings and cautions:
WARNING: To reduce the risk of personal injury from hot surfaces, allow the
drives and the internal system components to cool before touching them.
WARNING: To reduce the risk of electric shock or damage to the equipment:
I Do not disable the power cord grounding plug. The grounding plug is an
important safety feature.
I Plug the power cord into a grounded (earthed) electrical outlet that is
easily accessible at all times.
I Unplug the power cord from the power supply to disconnect power to the
equipment.
CAUTION: Protect the server from power fluctuations and temporary
interruptions with a regulating uninterruptible power supply (UPS). This device
protects the hardware from damage caused by power surges and voltage spikes
and keeps the system in operation during a power failure.
CAUTION: Always operate the Compaq ProLiant DL320 server with the system
access panel closed. The server cannot be properly cooled when the system
128276-B21
128277-B21
128278-B21
128279-B21
179322-001
203836-001
on-fault-to
Page 1 - Page 2 - Page 3 - Page 4 - Page 5 - Page 6 -

3prime solutions for all your HP requirements

     
 