Data Replication Manager HSG80 ACS Version 8.5P Operations Guide for Novell NetWare Version 5.1 First Edition (April 2001) Part Number: EK-DRMNN-OA. A01 Compaq Computer Corporation 2001 Compaq Computer Corporation. Com paq, the Compaq logo, and StorageWorks Registered in U.S. Patent and Trademark Office. SANworks is a trademark of Compaq Information Technologies Group, L.P. in the United States and other countries. Windows and Windows NT are trademarks of Microsoft Corporation in the United States and other countries. NetWare is a trademark of Novell Corporation in the United States and other countries. All other product names mentioned herein may be trademarks of their respective companies. Confidential computer software. Valid license from Compaq required for possession, use or copying. Consistent with FAR 12.211 and 12.212, Commercial Computer Software, Computer Software Documentation, and Technical Data for Commercial Items are licensed to the U.S. Government under vendor's standard commercial license. Com paq shall not be liable for technical or editorial errors or omissions contained herein. The information in this document is provided "as is" without warranty of any kind and is subject to change without notice. The warranties for Compaq products are set forth in the express limited warranty statements accompanying such products. Nothing herein should be construed as constituting an additional warranty. Com paq service tool software, including associated documentation, is the property of and contains confidential technology of Compaq Computer Corporation. Service customer is hereby licensed to use the software only for activities directly relating to the delivery of, and only during the term of, the applicable services delivered by Compaq or its authorized service provider. Customer may not modify or reverse engineer, remove, or transfer the software or make the software or any resultant diagnosis or system management data available to other parties without Compaq's or its authorized service provider's consent. Upon termination of the services, customer will, at Compaq's or its service provider's option, destroy or return the software and associated documentation in its possession. Printed in the U.S.A. Data Replication Manager HSG80 ACS Version 8.5P Operations Guide for Novell NetWare Version 5.1 First Edition (April 2001) Part Number: EK-DRMNN-OA. A01 Contents About This Guide Getting Help. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xiii Compaq Website . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xiii Compaq Technical Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xiii Precautions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xiv Electrostatic Discharge Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xiv Component Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xiv Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xv Special Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xv Text Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xvi Related Publications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xvii Data Replication Manager Solution Kit for Novell NetWare . . . . . . . . . . . . . . . . . . . . . . . . . . . xviii Revision History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xviii Chapter 1 Introduction to Data Replication Manager Data Replication Manager Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Peer-to-Peer Remote Copy Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Hardware Redundancy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Hardware Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Cabinet Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 ESA12000 Storage Cabinet. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 EMA12000 Modular Storage Cabinet. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Fibre Channel Gigabit Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Gigabit Interface Converters (GBIC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Power Distribution Unit (PDU). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110 Fully-Redundant Power (Optional) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110 Host Bus Adapters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111 Hardware Configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111 iv Data Replication Manager HSG80 ACS Version 8.5P Operations Guide for Novell NetWare Version 5.1 Software Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114 Array Controller Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114 StorageWorks Command Console (Optional) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114 Required Hardware and Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114 Chapter 2 Remote Copy Set Features Remote Copy. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Remote Copy Sets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Non-Remote Copy Sets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Operation Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Synchronous Operation Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Asynchronous Operation Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Operation Mode Considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Outstan ding_IO Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Synchronous . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Asynchronous . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Outstanding Write Operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 High Outstanding I/O Values . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Low Outstanding I/O Values . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Suspend/Resume . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Error Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Association Sets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Association Set Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 FAIL_ALL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Write History Logging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Mini-merge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Fast-Failback . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Log Unit Restrictions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Log Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 210 ORDER_ALL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 210 Failover . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 211 Planned Failover . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 211 Unplanned Failover. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 211 Failback . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 211 Chapter 3 Getting Started Site, Host, and Solution Preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 Host Bus Adapter Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Setting Up the Fibre Channel Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 v Setting Up the Fiber Optic Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 Host-to-Switch Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 Switch-to-Controller Connections. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 Chapter 4 Configuring a Data Replication Manager Solution Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 Restrictions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 Configuration Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 Configuration Procedures Outline . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 Target Site . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 Initiator Site. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 Configure the Controllers at the Target Site . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 Example Display 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 Example Display 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 Example Display 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 410 Example Display 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 411 Example Display 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 412 Example Display 6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 412 Example Display 7 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 413 Example Display 8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 414 Configure Storage at the Target Site . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 414 Devices and StorageSets. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 414 Creating Storage Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 415 Example Display 9 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 415 Cabling the Target Site . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 416 Connect Fiber Optic Cables Between the Controllers and Fiber Channel Switches . . . . . 416 Connect the Target Site to the External Fiber Link . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 417 Long Wave GBICs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 418 Other Transport Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 418 Configure the Host at the Target Site . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 419 Install the Host Bus Adapters and Drivers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 419 Install Secure Path . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 419 Install SWCC (Optional) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 420 Connect Fiber Optic Cables Between the Hosts and the Switches . . . . . . . . . . . . . . . . . . 420 Connecting the Fiber Optic Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 420 Example Display 10 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 421 Rename the Host Connections at the Target Site . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 422 Example Display 11 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 423 Configure the Controllers at the Initiator Site . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 423 Controller Configuration Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 423 vi Data Replication Manager HSG80 ACS Version 8.5P Operations Guide for Novell NetWare Version 5.1 Example Display 12 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 424 Example Display 13 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 426 Example Display 14 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 426 Example Display 15 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 427 Example Display 16 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 429 Example Display 17 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 430 Example Display 18 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 430 Example Display 19 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 431 Configure Storage at the Initiator Site. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 432 Devices and StorageSets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 432 Creating Storage Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 432 Example Display 20 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 433 Cabling the Initiator Site . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 434 Connect Fiber Optic Cables Between the Controllers and Fibre Channel Switches . . . . . . 434 Connect the Initiator Site to the External Fiber Link. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 435 Long Wave GBICs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 435 Other Transport Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 435 Create Remote Copy Sets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 436 Prepare the Initiator Site . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 436 Create Connections From the Target Site . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 437 Create RCS from the Initiator Site . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 437 Example Display 21 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 438 Set Failsafe at the Initiator Site (Optional) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 439 Creating Log Units and Association Sets (Optional) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 439 Creating a Log Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 439 Example Display 22 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 440 Example Display 23 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 440 Creating Association Sets and Assigning a Log Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 441 Example Display 24 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 441 Example Display 25 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 442 Configure the Host at the Initiator Site . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 443 Install the Host Bus Adapters and Drivers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 443 Install Secure Path . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 443 Install SWCC (Optional) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 444 Connecting Fiber Optic Cables Between the Hosts and the Switches . . . . . . . . . . . . . . . . . 444 Connecting the Fiber Optic Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 444 Example Display 26 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 446 Rename the Host Connections at the Initiator Site . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 447 Example Display 27 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 448 Enable Access to the Hosts at the Initiator Site . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 449 Install NetWare Cluster Services (NWCS) Version 1.01 (Optional) . . . . . . . . . . . . . . . . . . . . . 450 Document Your Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 450 vii Terminal Emulator Session . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 450 SHOW Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 450 Example Display 28 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 451 Example Display 29 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 452 Example Display 30 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 453 Example Display 31 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 454 Example Display 32 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 454 Chapter 5 Managing Site Failover and Failback Procedures Power Up Data Replication Manager Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 Target Site Powerup Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 Initiator Site Powerup Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 Power Down Data Replication Manager Systems. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 Initiator Site Power Down Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 Target Site Power Down Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 Site Failover Basic Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 Failback Procedure Choices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55 Data Replication Manager Configuration Basics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56 Planning Considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 Planned Failover Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58 Initiator Site Preparation Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58 Target Site Failover Procedure. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 510 Target Host Setup Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 511 Simple Failback Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 512 Initiator Site Failback Preparation Procedure. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 512 Target Site Simple Failback Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 513 Initiator Site Cleanup Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 514 Unplanned Failover . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 516 Target Site Failover Procedure. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 516 Full Failback Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 518 Initiator Site Preparation Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 518 Target Site Preparation Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 520 Initiator Site Connections Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 521 Target Site Copy Data Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 521 Initiator Site Return Control Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 522 Target Site Restore Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 522 Initiator Site Restoration of Target Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 523 New Hardware Failback Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 525 Initiator Site Preparation Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 525 Target Site Preparation Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 527 viii Data Replication Manager HSG80 ACS Version 8.5P Operations Guide for Novell NetWare Version 5.1 Initiator Site Connections Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 528 Target Site Copy Data Procedure. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 528 Initiator Site Return Control Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 529 Target Site Restore Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 529 Initiator Site Restoration of Target Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 530 Chapter 6 Troubleshooting HSG80 Array Controller Operating Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62 Forced Errors Detected During Copy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62 Read Errors Detected During Full Copy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62 Dual Redundancy During Failback . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62 Failsafe Lock Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63 Link Failure Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63 Remote Copy Set Member Failures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63 Remote Copy Set Worldwide LUN ID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64 Write History Logging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64 Component Failures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64 Failure Notification. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64 HSG80 Array Controller Failure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65 SWCC Failure. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65 Failure of One Member in a Dual Redundant Controller Pair . . . . . . . . . . . . . . . . . . . . 65 Failure of Both Fiber Optic Cables or Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66 Failure Modes of a DT System In Normal Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66 Failure at Target Site after Failover . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68 Chapter 7 Configuration Variations Cascaded Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72 Hopping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72 Cascaded Switches Configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73 Multiple Intersite Links . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75 DataSafe Solutions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76 DataSafe Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77 DataSafe Configuration Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77 Switch Zoning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79 SAN Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79 Zone Membership . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79 Resource Partitioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 710 Data Security. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 710 Homogeneous Environment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 711 ix Zoning Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 712 Planning Considerations for Homogeneous Configurations That Require Zoning. . . . . . . . . . 713 Windows 2000 Using Secure Path . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 713 More than 64 Host Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 713 Prevent Host Bus Adaptor (HBA) from Seeing All Active Host Ports . . . . . . . . . . . . . . . 714 Zoning A DRM Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 714 Zoning the Green Zone_Top and Green Zone_Bottom (Example) . . . . . . . . . . . . . . . . . . 718 Zoning the Blue Zone_Top and Blue Zone_Bottom (Example) . . . . . . . . . . . . . . . . . . . . 721 Zoning the Red Zone_Top and Red Zone_Bottom (Example) . . . . . . . . . . . . . . . . . . . . . 724 Create the Zone Names . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 726 Create the Configuration Name. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 727 SHOW Command Examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 728 switchShow command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 728 fabricShow command. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 730 uRouteShow command. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 731 topologyShow command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 731 nsShow command. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 732 nsAllShow command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 733 errShow command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 734 Appendix A Status Comparison Target Site Terminal Emulator Session . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A1 Issuing SHOW Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A2 Example Display 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A3 Example Display 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A4 Example Display 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A4 Example Display 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A5 Example Display 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A5 Appendix B Replicating Storage Units Cloning Data for Backup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B3 Snapshot . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B7 Snapshot Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B8 Glossary Index x DataData Replication Manager HSG80 ACS Version 8.5P Operations Guide for Novell NetWare Version 5.1 Figures Figure 11. ESA12000 storage building block . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Figure 12. Additional components for ESA12000 Data Replication Manager . . . . . . . . . . . . . 16 Figure 13. Components for EMA12000 modular storage Data Replication Manager. . . . . . . . 18 Figure 14. Fibre Channel SAN Switch 16 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Figure 15. Fibre Channel SAN Switch 8-EL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Figure 16. Fibre Channel-based, ESA12000 DT storage subsystem (with fully-redundant power). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111 Figure 17. Fibre Channel-based, EMA12000 DT modular storage subsystem (with fully-redundant power). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112 Figure 21. Remote copy set operation modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Figure 22. Location of association sets on the initiator controller pair . . . . . . . . . . . . . . . . . . . 27 Figure 31. Locations and names of components for connecting fiber optic lines . . . . . . . . . . . 34 Figure 41. Data Replication Manager basic configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 Figure 42. Switch port locations on a Fibre Channel switch . . . . . . . . . . . . . . . . . . . . . . . . . . 417 Figure 43. Cabling between the controllers and switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . 418 Figure 44. Cabling from the target site to the initiator site . . . . . . . . . . . . . . . . . . . . . . . . . . . 419 Figure 45. Cabling between the hosts and the switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 422 Figure 46. Host renaming worksheet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 423 Figure 47. Port locations on the Fibre Channel switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 435 Figure 48. Cabling between the controllers and Fibre Channel switches . . . . . . . . . . . . . . . . 436 Figure 49. Cabling from the initiator site to the target site . . . . . . . . . . . . . . . . . . . . . . . . . . . 437 Figure 410. Cabling between the hosts and the switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 446 Figure 411. Data Replication Manager cabling at initiator and target sites. . . . . . . . . . . . . . . 447 Figure 412. Host renaming worksheet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 449 Figure 51. Data Replication Manager basic configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56 Figure 71. Cascaded switches in DRM environment, with 0 hops from host, and 3 hops to controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74 xi Figure 72. Cascaded switches in DRM environment, with 3 hops from host, and 3 hops to controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75 Figure 73. Multiple intersite links . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76 Figure 74. DataSafe (firewall) configuration in DRM environment . . . . . . . . . . . . . . . . . . . . 78 Figure 75. Zoning in homogeneous environment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 712 Figure 76. Zoning in a DRM homogeneous environment . . . . . . . . . . . . . . . . . . . . . . . . . . . 716 Figure 77. Blank zoning input form (template) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 717 Figure 78. Zoning a DRM example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 718 Figure 79. Green Zone_Top and Green Zone_Bottom input form. . . . . . . . . . . . . . . . . . . . . 719 Figure 710. Blue Zone_Top and Blue Zone_Bottom input form . . . . . . . . . . . . . . . . . . . . . . 722 Figure 711. Red Zone_Top and Red Zone_Bottom input form . . . . . . . . . . . . . . . . . . . . . . . 725 Figure B1. Steps the CLONE utility follows for duplicating unit members . . . . . . . . . . . . . . B4 Figure B2. Snapshot unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B7 xii Data Replication Manager HSG80 ACS Version 8.5P Operations Guide for Novell NetWare Version 5.1 Tables Table 11 ESA12000 Storage Cabinet Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Table 12 EMA12000 Modular Storage Cabinet Components . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Table 21 Data Replication Manager Switch Settings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 215 Table 31 Overview of Required Connections. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 Table 41 Restrictions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 Table 51 Failover Scenarios . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 Table 61 Failure Modes of a DT System with Normal Operation . . . . . . . . . . . . . . . . . . . . . . . 66 Table 62 Target Site DT Failure Modes After Failover. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68 Table 71 DRM Hop Rules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73 Table 72 Multiple Intersite Link Restrictions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76 Table 73 Zoning Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 713 Table 74 Zoning Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 713 Table B1 Cloning and Snapshot Comparison . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B2 About This Guide This guide describes the Data Replication Manager and how to use it during a failover/failback situation running on the HSG80 Array Controller. See the documentation that accompanied the subsystem for detailed information about subsystem enclosures and their components. Getting Help If you have a problem and cannot find the information you need to resolve it in this guide, you can get further information and other help in the following locations: Compaq Website The Compaq website has information on this product as well as the latest drivers and Flash ROM images. You can access the Compaq website by logging on to the Internet at: http://www.compaq.com/storage Compaq Technical Support Use the following to connect with Compaq technical support: s United States and Canada, call 1-800-652-6672 s Outside the United States and Canada, visit the Compaq website at: http://www.compaq.com/storage xiv Data Replication Manager HSG80 ACS Version 8.5P Operations Guide for Novell NetWare Version 5.1 Precautions Follow the precautions listed in the sections "Electrostatic Discharge Precautions" and "Component Precautions" when carrying out the procedures outlined in this guide. Electrostatic Discharge Precautions Static electricity collects on all nonconducting material, such as paper, cloth, and plastic. An electrostatic discharge (ESD) can easily damage a controller or other subsystem component, even though you may not see or feel the discharge. Follow these precautions whenever you're servicing a subsystem or one of its components: s Always use an ESD wrist strap when servicing the controller or other components in the subsystem. Make sure that the strap contacts bare skin and fits snugly, and that its grounding lead is attached to a bus that is a verified earth ground. s Before touching any circuit board or component, always touch a verifiable earth ground to discharge any static electricity that may be present in your clothing. s Always keep circuit boards and components away from nonconducting material. s Always keep clothing away from circuit boards and components. s Always use antistatic bags and grounding mats for storing circuit boards or components during replacement procedures. s Always keep the ESD cover over the program card when the card is in the controller. If you remove the card, put it in its original carrying case. Never touch the contacts or twist or bend the card while you're handling it. s Never touch the connector pins of a cable when it is attached to a component or host. Component Precautions System components referenced in this guide comply with regulatory standards and the use of other components in their place may violate country standards, negate regulatory compliance, or invalidate the warranty on your product. About This Guide xv Conventions To help you find what you are looking for, this book uses the special notices and typographical conventions described in the following sections. Special Notices This book does not contain detailed descriptions of standard safety procedures; however, it does contain warnings for procedures that could cause personal injury, and cautions for procedures that could damage the controller or its related components. Look for these symbols when you are carrying out the procedures in this book: WARNING: Text set off in this manner indicates that failure to follow directions in the warning could result in bodily harm or loss of life. CAUTION: Text set off in this manner indicates that failure to follow directions could result in damage to equipment or loss of information. IMPORTANT: Text set off in this manner presents clarifying information or specific instructions. NOTE: Text set off in this manner presents commentary, sidelights, or interesting points of information. xvi Data Replication Manager HSG80 ACS Version 8.5P Operations Guide for Novell NetWare Version 5.1 Text Conventions Convention Meaning ALLCAPS Command syntax that must be entered exactly as shown, for example: SET FAILOVER COPY=OTHER Command syntax that is discussed within text, for example: ALLCAPS "Use the SHOW SPARESET command to show the contents of the spareset." Monospaced Screen displays are in monospaced font. Sans serif italic Command variables or numeric values that you supply, for example: Sans serif italic SHOW RAIDset-name or SET THIS_CONTROLLER PORT_1_SCS_NODENAME=xxxxxx References to other books, for example: Serif italic "See the Compaq StorageWorks HSJ80 Array Controller Configuration Guide for details." . Indicates that a portion of an example or figure has been omitted. About This Guide xv ii Related Publications The following table lists some of the documents that you will need to refer to when connecting, configuring, and operating your DRM solution. Document Title Part Number Compaq StorageWorks HSG80 Array Controller ACS V8.5 Configuration Guide EK-HSG85-CG. B01 Compaq StorageWorks HSG80 Array Controller ACS V8.5 CLI Reference Guide EK-HSG85-RG. A01 Compaq StorageWorks HSG80 Array Controller ACS V8.5 Maintenance and EK-HSG84-SV. C01 Service Guide Compaq StorageWorks Fibre Channel Storage Switch Service Guide AA-RHBZA-TE Compaq StorageWorks Fibre Channel Storage Switch User's Guide AA-RHBYA-TE Compaq StorageWorks Fibre Channel SAN Switch Management Guide AA-RMMJA-TE Compaq StorageWorks RA8000/ESA12000 and MA8000/EMA12000 Solution AA-RFB9D-TE Software V8.5c for Novell NetWare Installation Reference Guide Compaq StorageWorks Secure Path Version 3.0 for Novell NetWare 165993-B21 Compaq SANWorks Secure Path Version 3.0 for Novell Netware Installation and AA-RN72A-TE Reference Guide Compaq StorageWorks 64-Bit/66-MHz Fibre Channel Host Bus Adapter 122833-001 Installation Guide Compaq StorageWorks Ultra SCSI RAID Enclosure (DS-BA370-Series) User's EKBA370UG Guide Compaq StorageWorks Command Console Version 2.2 (HSG80) for AA-RFA2D-TE RA8000/ESA12000 User's Guide Compaq StorageWorks Command Console Version 2.3 User Guide AA-RFA2F-TE Compaq StorageWorks Model 2100 and 2200 Ultra SCSI Controller Enclosure EK-SE2C8-UA. B01 User Guide Compaq StorageWorks Enclosure 4200 Family LVD Disk Enclosure User Guide EK-SW2ZS-UA. B01 Compaq SANworks SAN Switch Zoning Reference Guide EK-P20ZG-GA. A01 xviii Data Replication Manager HSG80 ACS Version 8.5P Operations Guide for Novell NetWare Version 5.1 Data Replication Manager Solution Kit for Novell NetWare The Data Replication Manager (DRM) Solution kit part number for DRM operating on this operating system is: s Novell NetWare Solution Kit Part Number = 231844-B21 / QB-6BTAH-SA The following components are included in the DRM Solution kit: DRM Solution CD s Compaq SANworks Data Replication Manager HSG80 ACS Version 8.5P Operations Guide for Novell NetWare Version 5.1 s Compaq SANworks Data Replication Manager HSG80 ACS Version 8.5P Release Notes for Novell NetWare Version 5.1 s Compaq SANworks Application Note: Data Replication Manager over an ATM Link Supporting OSG Version 2.2.5 s Compaq SANworks Application Note: Data Replication Manager over a WDM-enabled Intersite Link s Compaq SANworks Application Note: DRM Using Very Long Distance GBICs Additional components not included in the DRM Solution kit that are required to run the Data Replication Manager solution are available from other kits: s Secure Path Version 3.0 for Novell NetWare Version 5.1 s HSG80 Solution Novell NetWare Version 5.1 Platform Kit Revision History Revision Level Date Revision A, EK-DRMNN-OA. A01 April 2001 1 Chapter Introduction to Data Replication Manager This chapter introduces Data Replication Manager and describes the required hardware and software components. This chapter covers the following topics: s "Data Replication Manager Overview" on page 11 "Peer-to-Peer Remote Copy Function" on page 12 "Hardware Redundancy" on page 12 "Hardware Components" on page 12 "Hardware Configurations" on page 111 "Software Components" on page 113 s "Additional Resources for Required Components and Software" on page 114 Data Replication Manager Overview Data Replication Manager (DRM) provides a disaster-tolerant (DT) storage solution through the use of hardware redundancy and data replication across multiple sites separated by some distance. A Data Replication Manager configuration consists of two sites. The initiator site carries out primary data processing. Target sites are used for data replication. Since data processing occurs at the initiator site, the data is replicated or mirrored to the target sites. If a significant failure happens to the initiator site, data processing can be resumed at the target sites, where the data is intact. 12 Data Replication Manager HSG80 ACS Version 8.5P Operations Guide for Novell NetWare Version 5.1 The DRM sites are connected over some distance via fiber optic cable or ATM. Data Replication Manager uses Fibre Channel switches to send the data between the sites. If sites are too distant to communicate via Fibre Channel, other hardware may be inserted between the sites. Peer-to-Peer Remote Copy Function Data Replication Manager uses the peer-to-peer remote copy function of the HSG80 controller to achieve data replication. HSG80 controller pairs at the initiator site are connected to their partner HSG80 controller pairs at the target site. Remote copy sets are created from units at the initiator and target sites. These remote copy sets are mirrors of each other. As data is written to a unit at the initiator, it is mirrored to its remote copy set partner unit at the target site. The HSG80 controllers provide failover and failback capabilities in case of failures. Failover makes the data available at the target site after a failure. Failback is used to move data operations back to the initiator once it has been brought back on-line. Hardware Redundancy Data Replication Manager provides hardware redundancy. In the face of single component failures at a site, Data Replication Manager will failover to a redundant component at that site to allow continued operations. For example, if one of the dual-redundant Fibre Channel links between the sites were to fail, Data Replication Manager would switch to the other link. Hardware Components Data Replication Manager uses a minimum of two HSG80 array controller pairs: one at the initiator site and one at the target site. Each site must have one or more ESA12000 cabinets or EMA12000 modular storage cabinets: s RA8000/ESA12000 cabinets are equipped with one or more BA370 enclosures and disk Storage Building Blocks (SBBs). Each BA370 enclosure holds 24 disks. s MA8000/EMA12000 modular storage cabinets are equipped with one or more controllers and modular disk SBBs. Introduction to Data Replication Manager 1 3 The hosts at the initiator and target sites are connected to a pair of dual redundant HSG80 array controllers, which are located inside of these enclosures. For complete details on this equipment, refer to the Compaq StorageWorks RA8000/ESA12000 and MA8000/EMA12000 Fibre Channel Solution Software V8.5c for Novell NetWare Installation Reference Guide. NOTE: While this documentation addresses ESA12000 storage cabinets as a primary unit for Data Replication Manager configurations, The Compaq DT solution will function in any equivalent cabinet that houses a BA370 enclosure. For the EMA12000 modular storage cabinets, the Compaq DT solution will function in any equivalent cabinet that houses the same number of controllers and an equivalent drive configuration. Additionally, cabinet configurations may be combined between the ESA12000 cabinets and EMA12000 modular storage cabinets. For example, if the configurations are equivalent, an ESA12000 cabinet may be used at one site (initiator or target) and an EMA12000 modular storage cabinet may be used at the associated site (target or initiator). Connections between the controllers and hosts are made at each site with two Fibre Channel switches and two host bus adapters. Short-wave Gigabit Interface Converters (GBICs) connect the host HBA and controllers to the switches at each site. Extended GBICs or ATM connect the initiator and target switches together if they are more than 500 meters apart. Cabinet Components Tables and figures throughout this chapter show hardware that is necessary or optional to complete a modular Data Replication Manager solution for each of two types of cabinet configurations, the ESA12000 cabinet and the EMA12000 modular storage cabinet. For detailed information about these components, refer to the following documents: s Compaq StorageWorks HSG80 Array Controller ACS V8.5 Configuration Guide s Compaq StorageWorks HSG80 Array Controller ACS V8.5 CLI Reference Guide s Compaq StorageWorks HSG80 Array Controller ACS V8.5 Maintenance and Service Guide. 14 Data Replication Manager HSG80 ACS Version 8.5P Operations Guide for Novell NetWare Version 5.1 ESA12000 Storage Cabinet The ESA12000 storage building block cabinet houses the BA370 enclosures, which contain the components listed in Table 11. Table 11 ESA12000 Storage Cabinet Components Two HSG80 Fibre Channel RAID array controllers One Environmental Monitoring Unit (EMU) One or two AC input power controllers Up to 24 disk drive storage building blocks (SBBs) per BA370 enclosure Five to eight 180-watt power supplies Dual external cache batteries (ECBs) Eight cooling fans Six single-ended I/O Ultra SCSI modules One Power Verification and Addressing (PVA) module Two cache modules (512 MB each required) for each HSG80 Introduction to Data Replication Manager 1 5 Figure 11 shows the initial storage building block parts inside the ESA12000 cabinet with a 24 disk drive capacity. Throughout this chapter, figures and text outline additional hardware that is necessary or optional to complete a Data Replication Manager solution. CXO6843A Figure 11. ESA12000 storage building block 16 Data Replication Manager HSG80 ACS Version 8.5P Operations Guide for Novell NetWare Version 5.1 Figure 12 shows additional components that must be added to the ESA12000 building block to support a Data Replication Manager solution, including Fibre Channel switches. The optional redundant power distribution unit is also shown. 1. Top Fibre Channel switch, 8- or 16-port 2. Bottom Fibre Channel switch, 8- or 16- port 3. Redundant power distribution unit (optional) 1 2 3 CXO6844A Figure 12. Additional components for ESA12000 Data Replication Manager Introduction to Data Replication Manager 1 7 EMA12000 Modular Storage Cabinet The EMA12000 modular storage building block cabinets include power distribution units, are pre-cabled, and contain the components listed in Table 12. Table 12 EMA12000 Modular Storage Cabinet Components Two HSG80 Fibre Channel RAID array controllers Two Environmental Monitoring Units (EMUs) Two AC input power controllers Modular disk drive storage building blocks (SBBs): D14 - Up to 42 drives per controller subsystem S14 - Up to 72 drives per controller subsystem Blue - Up to 42 drives per controller subsystem Dual power supplies, per shelf Dual external cache batteries (ECBs) Dual Cooling fans, per shelf Six single-ended I/O Ultra SCSI modules Two cache modules (512 MB each required) 18 Data Replication Manager HSG80 ACS Version 8.5P Operations Guide for Novell NetWare Version 5.1 Figure 13 shows an EMA12000 modular building block that supports a Data Replication Manager solution. The modular storage building block consists of the controller enclosure and the disk enclosure. The redundant power distribution unit is also shown. 1. Controller enclosure component of modular storage building block 2. Disk enclosure component of modular storage building block 1 3. Redundant power distribution unit 2 3 CXO7343A Figure 13. Components for EMA12000 modular storage Data Replication Manager Switches are placed in a different cabinet in this configuration of the EMA12000 D14 high performance modular storage cabinet. A command center cabinet can be used to contain the switches. Throughout this chapter, figures and text outline additional hardware that is necessary or optional to complete a modular Data Replication Manager solution. Introduction to Data Replication Manager 1 9 Fibre Channel Switches The Fibre Channel switches shown in Figure 14 and Figure 15 are two types of SAN switches used to connect the controllers to the hosts and to link the initiator and target sites together. The figures illustrate, respectively, the Fibre Channel SAN Switch 16 and the Fibre Channel SAN Switch 8-EL. The ports hold short-wave, long-wave, or very long distance Gigabit Interface Converters, which are described in the next section. Refer to the Compaq StorageWorks Fibre Channel Storage Switch User's Guide for an in-depth look at the features and functions of the Fibre Channel switches. Refer to the Compaq StorageWorks Fibre Channel SAN Switch Management Guide for additional detail on SAN switches. CXO7085A Figure 14. Fibre Channel SAN Switch 16 CXO7337A Figure 15. Fibre Channel SAN Switch 8-EL Gigabit Interface Converter (GBIC) GBICs are the converters that are inserted into the ports of the Fibre Channel switch and serve as the interface between the fiber optic cables and the switch. Short-wave GBICs are used with a 50-micron multi-mode fiber optic cable (SC-terminated) to connect the components at the initiator and target sites (host-to-switch; controller-to-switch). The maximum distance that short-wave GBICs support is 500 meters. Long-wave GBICs are used with 9-micron single-mode fiber optic cables (SC-terminated) to link the initiator and target sites. Standard long-wave GBICs connect switches that are up to 10 kilometers apart. 110 Data Replication Manager HSG80 ACS Version 8.5P Operations Guide for Novell NetWare Version 5.1 Power Distribution Unit (PDU) The PDU component is included with the ESA12000 and EMA12000 cabinets: s For the RA8000/ESA12000 cabinets, the PDU is used to distribute power to the BA370s and switches. You can order a second PDU to support a fully-redundant RA8000/ESA12000 power configuration. s For the MA8000/EMA12000 cabinets, the PDU is used to distribute power to the modular configurations of controllers and switches. PDU redundancy is included with MA8000/EMA12000 modular configurations. For more detailed information, refer to theCompaq StorageWorks RA8000/ESA12000 and MA8000/EMA12000 Fibre Channel Solution Software V8.5c for Novell NetWare
| 122833-001 165993-B21 231844-B21 AA-RFA2D-TE AA-RFA2F-TE AA-RFB9D-TE AA-RHBYA-TE AA-RHBZA-TE AA-RMMJA-TE AA-RN72A-TE DS-BA370-Se EK-DRMNN-OA EK-HSG84-SV EK-HSG85-CG EK-HSG85-RG EK-P20ZG-GA EK-SE2C8-UA EK-SW2ZS-UA QB-6BTAH-SA |