DEC 3000-400 ~~~~~~~~~~~~ Configuring Environment *********************** System Electrical Specifications System Environmental Specifications ---------------------------------------------------------------------------- System Electrical Specifications Input voltage Automatically adjusting ac input for either 100-120 V ac or 220-240 V ac operation. Frequency range 47 to 63 Hz Power 420 watts input maximum, system only, power factor 0.6 minimum.
System Environmental Specifications Operating/Storage Conditions Temperature range 5C to 50C (41F to 122F) Temperature change rate 11C/hr (52F/hr) maximum Relative humidity 10% to 95% (noncondensing) Maximum altitude Maximum altitude Maximum wet bulb temperature 32C (90F) Minimum dew point 2C (36F) Nonoperating Conditions Temperature range -40C to 66C (40F to 151F) Relative humidity 95% @ 66C (150F) (may condense) Maximum altitude 4900 m (16,000 ft)
----------------------------------------------------------------------------
| |