DEC 3000-600 ~~~~~~~~~~~~ Configuring Environment *********************** Physical Characteristics Environment Electrical ---------------------------------------------------------------------------- Physical Characteristics ======================== *Desktop Dimensions* Height 12.7 cm (5.0 in) Width 51.0 cm (20.09 in) Depth 44.5 cm (17.50 in) Weight 20 kg (45 lb)
Environment =========== *Temperature* Operating 10C to 35C (50F to 95F) Operating Rate of change 11 C/hr (20 F/hr) maximum Nonoperating (packaged) -40 to 66 C (-40 to 151 F) Storage (unpackaged) 5 to 50 C (41 to 122 F) Nonoperating Rate of change 20 C/hr (36 F/hr) *Relative Humidity* Operating 10% to 90% (non condensing, no diskette) Nonoperating 10 to 95% (non condensing) Storage (unpackaged) 10% to 95% (non condensing) *Maximum Wet Bulb* Operating 28 C (82 F) Nonoperating (packaged) 46 C (115 F) Storage (unpackaged) 32 C (90F) *Minimum Dew Point* Operating 2 C (36 F) Storage (unpackaged) 2 C (36 F) *Altitude* Operating 2000 m (6562 ft) Nonoperating (packaged) 0 to 3600 m (0 to 12,000 ft)
Electrical ========== *Minimum/Maximum Values* Input Automatically adjusting AC input from 100-120 Vac to 220-240 voltage VAC Frequency 47-63 Hz range Power System only: 229 watts input typical. System and VRT19-HA monitor: 378 watts input typical, 478 watts maximum, power factor >0.5 typical.
----------------------------------------------------------------------------
| |