*AlphaServer 1000A* -
AlphaServer 1000A Pedestal & Rackmount
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
Configuring Environment
***********************
Physical Characteristics
Environmental Characteristics
Electrical Characteristics
----------------------------------------------------------------------------
Physical Characteristics
============================================================
Dimensions Pedestal
Height 46 cm (18.1 in)
Width 35.8 cm (14.1 in)
Depth 58.6 cm (23.1 in)
Weight 39 kg (86 lb) typical
51 kg (113 lb) maximum
Front 75 cm (29.5)
Rear 15 cm (6 in)
Sides none

Environmental Characteristics
=============================
Temperature (min/max)
Specifications Pedestal Rackmount
Operating 10-40C (50-104F) 10-35C (50-95F)
Non operating Not tested Not tested
Storage (60 days) -40-66C (-40-151F) -40-66C -40-151F)
Rate of Change 11C/hr (20F/hr)
Relative Humidity
Operating 20-80% noncondensing 20-80% noncondensing
Non operating 20-80% noncondensing 20-80% noncondensing
Storage (60 days) 10-95% noncondensing 10-95% noncondensing
Rate of Change 20%/hr 20%/hr
Maximum Wet Bulb
Operating 28 C (82 F)
Storage (60 days) 39 C (115 F)
Minimum Dew Point
Operating 12 C (36 F)
Storage (60 days) Not tested
Max Heat Dissipation
Single supply 2390 BTU/hr
Dual supply 4097 BTU/hr
Airflow and Quality
Intake Front Front
Exhaust Rear Rear
Altitude
Operating 2000 m (6562 ft) 2000 m (6562 ft)
Non operating 3600 m (12,000 ft) 3600 m (12,000 ft)
Mechanical Shock
Operating 7.5 G pk 10 ms
Non operating 20 G pk 30 ms 20 G pk 30 ms
Vibration (min/max)
Operating 10-500 Hz @ 0.1g peak 10-500 Hz @ 0.1g peak
Acoustics
Operating Average Declared Average Declared
6.2 law, B6.5 LwAd, B 6.2 LwA, B6.5 LwAd, B
Idle Average declared Average Declared
6.0 LwA, B6.3 LwAd, B 6.0 LwA, B6.3 LwAd, B

Electrical Characteristics
==========================
Minimum/Maximum Values
Specifications Pedestal Rackmount
Nominal ac voltage 100-120/220-240Vac 100-120/200-240Vac
Operating Voltage range 90-128/180-256 Vac 90-128/180-256 Vac
Power Source Phase Single Single
Nominal Frequency(Hz) 60/50 Hz 60/50 Hz
Frequency range(Hz) 59-61 Hz /49-51 Hz 59-61 Hz / 49-51 Hz
Maximum inrush current 50/50 Amps 50/50 Amps
RMS current at nominal 8.0 Amps/4.0 Amps 8.0 Amps/4.0 Amps
voltage (steady state) 4.6 Amps/2.2 Amps each supply
Single power supply
Dual power supply
Power Cord
Type IEC 320 C13 IEC 320 C13
Length 190 cm (75") 4.57 m (15 ft)
U.S Plug NEMA 5-15 NEMA 5-15

* Maximum operating temperature at Sea Level. Reduced by 1 C (1.8 F) for
each 600 m (2000 ft) above Sea Level.
** Higher altitudes are possible if maximum operating temperature is reduced
(see Temperature above); other restrictions may apply, such as maximum
permissible altitude for hard drive.