Product Details

AlphaServer 2100A LP -
AlphaServer 2100ALP
~~~~~~~~~~~~~~~~~~~
Configuring Environment
***********************
Physical Characteristics
Environmental
Electrical
Regulatory
----------------------------------------------------------------------------
Physical Characteristics
========================
Variable Installed Dimension
Height 17 cm (7 in.)
Width 45 cm (17.60 in.)
Depth 67.3 cm (26.5 in.)
Weight 34.1 kg (75 lb)

Environmental
=============
Variable Temperature
Operating* 10-35 C (50-95 F)
Non operating -40 -66 C (-40 -151 F)
Rate of change 11 C/hr (20 F/hr)
Relative Maximum Wet Bulb Temperature
Humidity
Operating* 10-90% noncondensing 28 C (82 F)
Non operating 46 C (115 F)
Rate of change 20% / hr
Minimum Dew Point
Operating 2 C (36 F)
Maximum Heat Dissipation
Operating 800 Watt (2,766 BTU/hr)
Air Flow and Quality
Operating 100 cubic feet/min.
Intake location Front
Exhaust location Rear
Altitude
Operating** 3048 m (10,000 ft)
Non operating 12,192 m (40,000 ft)
Mechanical Shock Vibration
Operating 20g pk for 10 +/- 3 ms 5-15.65 Hz @ 0.020" DA
15.65 - 200 Hz @ 0.25g peak
200-500 Hz @ 0.10g peak
Non operating 20g pk for 10 +/_ 3 ms 5-300 Hz @1.034g rms
Acoustics
Operating LNPEc (Bels)
6.6 maximum per ISO 7779

Electrical
==========
Variable Minimum/Maximum Values
Voltage Range 100-120/220-240 Vac
Power source phase Single
Nominal frequency (Hz) 50 - 60 Hz
Frequency Range(Hz) 57-63 / 47-53Hz
Maximum rated current 8.2a / 4.1a
Maximum power 810 W (PFC = 0.99, 8.2 A @ 100 V)
consumption (Watts)
Power cord
Type IEC 320 C13
Length 300 cm (118 in.)
U.S. plug NEMA 5-15, Socket EIC
320 Sheet, C-15

Regulatory
==========
Agency Approvals Reviewed To
UL Listed to UL1950 AS 3260 Australian Standard
CSA Certified to CAN/CSA 22.2 NZS 6661:1989 New Zealand Standard
No.950-M93 EN 60 950: 1992 European Norm
TUV EN 60950GS VDE 0805
IEC 950
FCC 15J Part 15 (Class A)
CE

* Maximum operating temperature at Sea Level. Reduce by 1 C (1.8 F) for
each 600 m (2000 ft) above Sea Level.
** Higher altitudes are possible if maximum operating temperature is reduced
(see Temperature, above); other restrictions may apply, such as maximum
permissible altitude for hard drives. _Top of page_
----------------------------------------------------------------------------
Page 1 - Page 2 -

3prime solutions for all your HP requirements

     
 


HP is a registered trademark