AlphaServer 8200, AlphaServer GS60 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ Configuring Environment *********************** Physical Characteristics Environmental Electrical Regulatory ---------------------------------------------------------------------------- Physical Characteristics ============================================================ Dimensions Specifications System Cabinet Rackmount System - H9A15 Cabinet Operating Shipping Operating Shipping Height 170.0 cm (67.0 194.0 cm 202.0 cm (79.5 225.4 cm (88.8 in.) (76.25 in.) in.) in.) Width 60.0 cm (23.6 91.5 cm (36.0 60.0 cm (23.6 91.5 cm (36.0 in.) in.) in.) in.) Depth 92.5 cm (36.4 121.5 cm (47.9 103.6 cm (40.8 121.5 cm (47.9 in.) in.) in.) in.) Weight Min Min 318 kg (700 352 kg (775 configuration: configuration: lb.) lb.) 318 kg ( 700 363 kg ( 800 lb ) lb ) Max Max configuration: configuration: 591 kg ( 1300 636 kg ( 1400 lb ) lb ) Clearances Operating Service Operating Service Front 1.0 m (40 in.) 1.5 m (40 in.) 1.0 m (40 in.) 1.5 m (59 in.) Rear .75 m 1.0 m (40 in.) .75 m (29.5 1.0 m (40 in.) (29.5in.) in.) Sides 0 0 0 0
Environmental ============= Temperature Specifications System Cabinet Rackmount System - H9A15 Cabinet Operating 10 to 35 C (50 to 95 10 to 35 C (50 to 90 F) F) Non Operating -40 to 66 C (-40 to -40 to 66 C (-40 to 151 F) 151 F) Humidity Operating 10% to 90% 10% to 90% Non Operating 10% to 95% 10% to 95% Altitude Operating 0 - 2.4 km (0 - 8200 ft.) 0 - 2.4 m (0 - 8200 ft.) Non Operating 9,100 m (30,000 ft.) 9,100 m (30,000 ft.) Vibration Operating 2 - 22 Hz @ 0.01"da min 2 - 22 Hz @ 0.01"da min Non Operating 22 - 500 Hz @ 0.25g max 22 - 500 Hz @ 0.25g max Heat Dissipation Min Config. Sys: 1 3,200 Btu/hr (930 W) 3,200 Btu/hr (930W) (sys cab) Fully Config. 9100 Btu/hr (2647 W) Max Single Cabinet Config: Sys:2 9,100 Btu/hr (2,647W) (sys cab) Fully Config. 21,300 Btu/hr (6234 W) Sys:3 (sys cab with 2 I/O exp cab)
_Top of page_ Electrical ========== Power Specifications System Cabinet Rackmount System - H9A15 Cabinet *US/Canada* *Europe/AP* *Japan* Nominal 202 - 240 (208) 202 - 240 (240) 202 - 240 (202) 200 - 240 V voltage V V V Frequency 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 47 -63 Hz range Phases Single phase Single phase Single phase Single phase line to line or line to line or line to line or line to neutral line to neutral line to neutral Max input 16 A rms 16 A rms 16 A rms Max Config: current/phase 13.3 A rms Surge current 80 A peak 80 A peak 80 A peak Rating 16 A 16 A 16 A Power Cord BN23H-4E BN20P-4E BN23H-4E part number Power Cord 4.5 meters 4.5 meters 4.5 meters length 15 feet 15 feet 15 feet Power Cap DEC DEC DEC Plugs from (system) 12-16886-00 12-30333-03 12-16886-00 Cab NEMA L6 - 30P NEMA L6 - 30P NEMA L6-20P (QTY= 2) Receptacle NEMA L6-30R IEC 309 (32A)4 NEMA L6-30R NEMA L6-20R 2 pole/3-wire (QTY=2) (220-240v) PCS/PDS/ BC26E BC26E PDU/UPS cable
Regulatory ========== Agency Approvals System Cabinet Rackmount System - H9A15 Cabinet UL Listed to UL1950 UL, CSA, IEC, FCC, CE CSA Certified to CAN/ CSA-C22.2,No. 950-M89 FCC Part 15 (Class A) CE Declaration #1171 Reviewed To EN 60950/A1,Jan. 1993, European Norm AS/NZS 3260:1993, Australia/New Zealand Standard EMKO-TSE {74-SEC}Summary of Nordic Deviations IEC950, 2nd Ed., 2nd Amend.
Minimally configured system contains one power supply, one CPU module one memory module, one System I/O module, one CD-ROM, and one RZ28 disk drive. Fully configured system contains two power supplies, one CPU module two memory modules, two System I/O modules, one CD-ROM, 16 RZ28 drives, two PCI shelves, and two StorageWorks shelves. Fully configured system and two expansion cabinets consist of the above "fully configured system" and two expansion cabinets which each contain one PCI shelf, 14 StorageWorks shelves, and 84 RZ28 drives. Receptacle type is Hubbell 332R6 or equivalent. Power system provides unity power factor which allows full utilization of the input line current (Watts=VA). _Top of page_ ----------------------------------------------------------------------------
| 12-16886-00 12-30333-03 |