Product Details
SANworks Network View - *Browser-based application to automatically map SAN topology, monitor itsavailability and display a map of the storage environment.*
----------------------------------------------------------------------------
Feature *Description*
*Current Version* 2.0B*5*
*Host/Server Operating Systems*
Windows NT 4.0*2*
Windows 2000*3*
Windows 2000 Datacenter v2.0
Tru64 Unix (v4.0F, v4.0G, v5.0a,
v5.1 or v5.1a)
Sun Solaris*4* v2.6, v7 or v8
OpenVMS v7.3, v7.3-1
HP-UX v11.0
AIX v4.3.2, v4.3.3
NetWare v4.2, v5.1, v6.0
*Hardware Support*
SANworks Management Appliance
HP StorageWorks Fibre Channel
Storage Hub 12 (with management
option)
HP StorageWorks Modular Data Router
HP StorageWorks Network Storage
Router Model M2402
Fibre channel switches:
HP StorageWorks Fibre Channel SAN
Switch/8
HP StorageWorks Fibre Channel SAN
Switch/16
HP StorageWorks Fibre Channel SAN
Switch 2/16
HP StorageWorks Fibre Channel SAN
Switch 8-EL
HP StorageWorks Fibre Channel SAN
Switch 16-EL
HP StorageWorks Fibre Channel SAN
Switch 2/8-EL
HP StorageWorks Fibre Channel SAN
Switch 2/16-EL
HP StorageWorks SAN Switch
Integrated/32
HP StorageWorks SAN Switch
Integrated/64
HP StorageWorks Fibre Channel
Arbitrated Loop Switch 8 (FC-AL)
Brocade SilkWorm Models 2400,
2800, 2050, 2250, 3800, 6400, or
12000
HP StorageWorks director 2/64
HP StorageWorks edge switch 2/16
HP StorageWorks edge switch 2/32
McData ED-5000 or 6064 Director
McData 3216 Fabric Switch
McData 3232 Fabric Switch
HP StorageWorks Modular Storage
Array Fabric Switch 6
RAID Storage Systems:
HP StorageWorks RAID Array 4100
HP StorageWorks Modular Array
6000 Fibre Channel
HP StorageWorks RAID Array 8000
Fibre Channel
HP StorageWorks Modular Array
8000/Enterprise Modular Array 12000
Fibre Channel
HP StorageWorks Enterprise
Storage Array 12000 Fibre Channel
HP StorageWorks Enterprise
Modular Array 16000 Fibre Channel
HP StorageWorks Enterprise
Virtual Array
HP StorageWorks Modular SAN Array
1000
EMC Symmetrix systems using the
Sym API 4.2 or 4.3
Server/host systems and associated
Host Bus Adapters (HBAs):
Windows NT (Intel) & Windows 2000
(Intel) - HP StorageWorks 2GB,
64-Bit/66MHz*1* (MSA 1000 only)
Windows NT (Intel) & Windows 2000
(Intel) - HP StorageWorks
64-Bit/33-MHz*1*
Windows NT (Intel) & Windows 2000
(Intel) - HP StorageWorks
32-bit/33-Mhz*1*
Windows NT (Proliant) & Windows
2000 (Proliant) - HP StorageWorks
64-bit/66-Mhz*1*
Windows 2000 for Datacenter - HP
StorageWorks 64-Bit/33-MHz*1*
Tru64 Unix (Alpha) - HP
StorageWorks 2 Gb, 64-bit/66 MHz*1*
for Tru64 UNIX and HP OpenVMS
(HSG80 only)
Tru64 UNIX (Alpha) - HP
StorageWorks 64-Bit/33-MHz*1*
Tru64 UNIX (Alpha) - HP
StorageWorks 32-bit/33-Mhz*1*
Solaris - HP StorageWorks
32-Bit*1* for Solaris
Solaris - HP StorageWorks 64-Bit
Sbus-to-Fibre Channel Host Bus
Adapter for Solaris
Open VMS (Alpha) - HP
StorageWorks 2 Gb, 64-bit/66 MHz*1*
for Tru64 UNIX and OpenVMS (HSG80
only)
OpenVMS (Alpha) - HP StorageWorks
64-Bit/33-MHz*1*
OpenVMS (Alpha) - HP StorageWorks
33-Bit/33-MHz*1*
HP-UX - HP StorageWorks
64-Bit/66-MHz*1*
AIX - HP StorageWorks
64-Bit/66-MHz*1*
NetWare (Intel) - HP StorageWorks
64-Bit/66-Mhz*1*
*Software Prerequisites*
SANworks Management Appliance
running OpenSAN Manager V1.0C
Fibre Channel switches:
If using HP StorageWorks 1Gb
Fibre Channel SAN Switches,
firmware version 2.1.9m or 2.6
If using HP StorageWorks 2Gb
Fibre Channel SAN Switches,
firmware version 3.02
If using Brocade SilkWorm Models
2400, 2800, 2050, 2250, or 6400,
firmware versions 2.1.9m, 2.2.1,
2.4.1f, or 2.6
If using Brocade SilkWorm Model
3800, firmware version 3.02
If using HP StorageWorks Fibre
Channel Arbitrated Loop Switch 8
(FC-AL), firmware version 1.00-G03
If using McData ED-5000 Director,
firmware version 1.2.02 pass 6
If using HP StorageWorks Fibre
Channel Storage Hubs, firmware
version 4.00-g06
If using HP StorageWorks Modular
Data Routers, firmware version 1187
If using HP StorageWorks RAID
Storage Systems, ACS version 8.5,
8.6-1
If using EMC Symmetrix, those
that support Sym API 4.2 & 4.3
Management Appliance running Open
SAN Manager (OSM) version 1.0C Fibre
Channel Switches and Routers:
If using HP StorageWorks 1 Gb
Fibre Channel SAN Switches,
firmware version 2.1.9m or 2.6
If using HP StorageWorks 2 Gb
Fibre Channel SAN Switches,
firmware version 3.02f If using HP
StorageWorks Core Switch 2/64,
firmware 4.0c
If using Brocade SilkWorm Models
2400, 2800, 2050, 2250, or 6400,
firmware versions 2.1.9m, 2.2.1,
2.4.1f, or 2.6c
If using Brocade SilkWorm Model
3800, firmware version 3.02f
If using Brocade 12000, firmware
version 4.0c
If using HP StorageWorks Fibre
Channel Arbitrated Loop Switch 8
(FC-AL), firmware version 1.00-G03
If using HP StorageWorks director
2/64, firmware version 2.0
If using HP Storage edge
switches, firmware version 2.0
If using McData ED-5000 Director,
firmware version 1.2.02 pass 6
If using McData 6064 Director,
firmware version 2.0 EFCM v6.0
If using McData 3216 or 3232
Fabric Switch, firmware version 2.0
If using HP StorageWorks Fibre
Channel Storage Hubs, firmware
version 4.00-g06
If using HP StorageWorks Modular
Data Routers, firmware version 1187
If using HP StorageWorks Network
Storage Router Model M2402,
firmware version 4.02aw
If using HP StorageWorks Modular
Storage Array Fabric Switch 6,
firmware version 101G06
RAID Storage Systems:
If using HP StorageWorks
Enterprise Virtual Array
VCS version 2.0
OSM version 1.0C SP2
If using HP StorageWorks RAID
Storage Systems
ACS version 8.6-1 or 8.7
OSM version 1.0C SP4
If using HP StorageWorks RAID
Array 4100
Sub-system firmware J51
Controller firmware 2.6
If using HP StorageWorks Modular
SAN Array 1000
Sub-system firmware 1.78
Controller firmware 1.14
If using EMC Symmetrix, those
that support Sym API 4.2 & 4.3
*Hardware Prerequisites* SANworks Management Appliance
*Client Web Browser Support* *Windows 2000:* Internet Explorer v5.01
& v5.5, Netscape v4.79
*Windows NT 4.0:* Internet Explorer
v5.5, Netscape v4.79
*Solaris 8.0:* Netscape v4.78
*Tru64 UNIX:* Netscape v4.78
*Note 1:* PCI-to-Fibre Channel Host Bus Adapter
*Note 2:* Requires Microsoft Service Pack 6a
*Note 3:* Requires Microsoft Service Pack 2
*Note 4:* The following patches need to be installed for the Solaris operating
system:
*Solaris V2.6:* 105181-23, 105210-33, 105284-37, 105568-21, 105591-09,
105633-49, 105669-10, 106040-15, 106125-10, 106841-01, 106842-09, 107733-09,
108091-03
*Solaris V7:* 106980-10, 107636-03, 106541-11, 107544-03, 109104-01,
106950-09, 106327-08, 106300-09, 107081-20
*Solaris V8:* 108940-07
The order of patch installation is dictated by the patch dependencies as
documented by Sun Microsystems for each patch. Patches can be obtained from
the http://access1.sun.com web site. However, patch 109104-* is no longer
available from access1. This is because Sun has rolled the functionality of
109104 into the latest kernel patch (106541-16). If a patch is not found or
not up to the latest revision, a warning message is displayed. In the case
of the 109104 patch, the warning message can be safely ignored if 106541-16
or greater is installed.
*Note 5:* Network View version 2.0B Update and Service Pack 1 may be
downloaded at:
http://h18000.www1.hp.com/products/sanworks/softwaredrivers/networkview/index.h
_Top of page_
Description
===========
HP SANworks Network View is a SAN management application providing a
consolidation point for storage network visualization, monitoring and
configuration. SAN devices, their Fibre Channel interconnects, and
associated status are automatically discovered and displayed in an intuitive
topographical network map.
SAN device management is made easy by double clicking on a device icon.
System performance bottlenecks are identified for proactive resolution and
planning. A JAVA applet based design allows remote SAN management from any
web browser.
Network View is easily installed on the Management Appliance and because it
is an appliance application; host operating system integration is not a
necessity.
Features
========
Automated in-band and out-of-band device discovery
Graphical SAN topology mapping of all Fibre Channel connected
devices and their interconnects
Graphical status display
Automated SAN availability monitoring and notification via e
mail and text pager when faults arise
SNMP trap forwarding
Custom notification set up
Performance monitoring and graphical trending of numerous switch
and HP StorageWorks RAID arrays, Modular arrays, Enterprise Virtual
arrays, performance metrics
Launch capability for all browser enabled device management
tools
Support for numerous HP and third party devices
_Top of page_
----------------------------------------------------------------------------
Page 1
-
3prime solutions for all your HP requirements
HP is a registered trademark